Harmonic Mitigation in a Single Phase Non-Linear Load Using SAPF with PI Controller

N/A
N/A
Protected

Academic year: 2017

Share "Harmonic Mitigation in a Single Phase Non-Linear Load Using SAPF with PI Controller "

Copied!
5
0
0

Texto

Loading

Imagem

Fig 1 .  3 rd  Harmonic distorted waveform
Fig 4. Single Tuned Filter
Fig 12. Non-linear load with SAPF and PI Controller
Table 2. THD table for current harmonic mitigation   Funda-mental   har-monic  % of THD  Before mitigation 62.45 %  % of THD    After mitigation   6.68%  H3  56.58  0.98  H5  16.81  1.75  H7  15.28  0.40  H9  7.84  0.83  H11  7.22  0.57  H13  4.38  0.27
+2

Referências

Documentos relacionados

The series active filter works as sinusoidal current source in phase with the input voltage, drawing from utility sinusoidal and balanced input currents with low total

Instantaneous power theory with PI- controlled APLC comprises a three-phase source, a nonlinear load (six pulse diode Rectifier RL load) and a PWM voltage source

Goertzel algorithm for reference current generation under unbalanced load conditions with DC voltage balancing using PI controller or SMC..

- settling the PLL loop that is used to generate the sinusoidal reference, Fig.21. This event can last up to 0, 5 s depending on the initial conditions,

Incase of direct control of current is provided to block the DC current component in order to avoid core saturation of the line frequency transformer connected

The result of optimized switching angles obtained from a proposed system that reduces the selected low order harmonics and minimizes THD% from single phase

In the paper ,a new single phase cascaded H- Bridge Nine – level inverter with boost converter and fuzzy logic controller using solar power source was simulated

In this case, the source voltage of 150V and load reference command of 160 V are maintained constant with step change in load at 0.5 sec.. In this case also the controller