• Nenhum resultado encontrado

Laboratory investigation of the effect of a new labyrinth with different length and width in the wing length of a triangular-shaped labyrinth weir

N/A
N/A
Protected

Academic year: 2017

Share "Laboratory investigation of the effect of a new labyrinth with different length and width in the wing length of a triangular-shaped labyrinth weir"

Copied!
5
0
0

Texto

(1)

ISSN 0976-2612, Online ISSN 2278–599X, Vol-7, Special Issue4-May, 2016, pp338-342

http://www.bipublication.com

Research Article

Laboratory investigation of the effect of a new labyrinth with different length

and width in the wing length of a triangular-shaped labyrinth weir

Amirreza Bahrebar, Hossien Azarpayvand3, moslem momni asl and farzane barati

Young Researchers and Elide Club, Yasuj Branch, Islamic Azad University. Yasuj, Iran

Bahrebarsh@yahoo.com

ABSTRACT

Due to minor changes in the static load on the crest in case of large fluctuations in flow rate,

polyhedral weirs, compared with other types of weirs, are considered as economic structures to control water levels in the irrigation networks. Using labyrinth weirs is an effective and economical approach to improve the efficiency of the weir by increasing its effective crest length. In this case, for a constant hydraulic height and width, it passes a greater discharge in comparison with other types of weirs. In this study, the V-shaped plan-form weirs are studied [1, 2]. Tests are conducted on 30 models with 7 different discharges, and in a total of 210 tests. The models include 30 V-shaped weirs with various lengths. The models are investigated in a flume with 8 m length, 0.35 m width and height of 0.40 m. The results of this study indicate that for all triangular-shaped weirs the ratio of discharge coefficient to P/ ( : total hydraulic load, P: weir height) is at first increased and after reaching a maximum, begins to be reduced. As the height of labyrinth on the weir wings increases, as a result of increases in effective length, the discharge coefficient is increased for a specific /P. The results also show that increasing the wing length reduces the discharge coefficient. Also, the discharge coefficient is greater for V-shaped weirs than linear ones.

Keywords: polyhedral weirs, the effective length of the crest, discharge coefficient, hydraulic height.

1. INTRODUCTION

One of the problems faced by the irrigation networks is changes in the discharge flowing through the intake structure due to sever fluctuations in water level in the main channel. Labyrinth weirs are of hydraulic structures used to adjust the water level and to control the flow in the canals and rivers and dams reservoirs. According to the relation between the discharge and hydraulic load in weirs, one approach to reduce the fluctuations arising from discharge changes is to

(2)

Figure 1 (a, b) shows sample weir models used in this study.

Figure 1-a) A sample labyrinth weirs used in the experiment with the width and height of 8 and 6 cm for the labyrinth, respectively.

Figure 1-b) A sample labyrinth weirs used in the experiment with the width and height of 4 and 6 cm for the labyrinth, respectively.

The first attempt to analyze the polyhedral weirs can be attributed to Hey and Tailor. These two researchers expressed the efficiency of polyhedral weirs by the ratio of . In this relation, is

the discharge of polyhedral weir with length of L; and is the discharge of a common (linear) weir with length of W (equivalent to the width of the main channel) in a certain hydraulic load. These studies revealed that the efficiency of polyhedral weirs is desired at low hydraulic loads. Darvas used the experimental results of polyhedral weirs for Veronora and Oven dams in Australia and represented some curves for designing this type of weirs. Raw and Indlecoffer used experimental results to investigate the effect of the corners of labyrinth weirs, and finally represented a relation to calculate the discharge within these types of weirs. United States Bureau of Reclamation (USBR) has conducted some studies on laboratory

model of polyhedral weirs for Utah and Hey-Ram dams. The reports released by the organization represents that there is a differences between results obtained by the USBR and those by Hey and Taylor. This difference results from applying Piezometric load rather than total water load by recent researchers [8, 9, and 10].

Lax used total water load instead of Piezometric load and his empirical formula for polyhedral weirs discharge indicated that the efficiency of polyhedral weirs in high water load values is significantly lower than that of other studies. Using dimensional analysis and comparing it with experimental

results, Lax and Hinchliff provided an approach to design polyhedral weirs with simplicity and accuracy higher than previous methods. Tolis et al. studied trapezoidal plan-form weirs and provided an approach to design based on different angles of [13, 14, and 18]. In this design approach is so that in a polyhedral weir, the angle and the number of cycles is changed to obtain the desired configuration and discharge.

Vermilton and Tsang studied the efficiency of polyhedral weirs during aeration and increase of dissolved oxygen in the river. They came to the conclusion that polyhedral weirs, in comparison with linear weirs, have a much better performance to increase the dissolved oxygen. Tolis et al. modified the design criteria for the polyhedral weir of Brazos dam while operating at low heads. Most used polyhedral weirs have a trapezoidal or triangular plan. The objective of this study is to investigate the hydraulic performance of V-shaped plan-form weirs and to compare them with each other and with linear plan-form weirs [16, 17].

2. METHODS AND MATERIALS

A) Laboratory Equipment

(3)

immediately after the pump and at the inlet. To feed the flume, the water is pumped from a main source in a closed cycle, and after passing through a tranquilizers located at the beginning of the flume, it flows into the flume. After passing through the laboratory flume, water flows into a tank measuring the volumetric discharge and then flows into the main tank. The laboratory flume used in this study has plexiglass floor and walls and is mounted on a steel truss. Figure 2 shows a view of the laboratory flume used in this study. Figure2. A view of the used laboratory flume

B) Measurements:

In order to determine the discharge coefficient for the weir, we need to measure the discharge passing through the weir as well as the hydraulic load over it. The flow discharge is calculated using the volumetric method.

Table1. For a labyrinth with 6 cm height and 4 cm width in the wing in a 60 cm triangular weir

The water depth is measured at upstream and downstream using a Vernier caliper mounted on an altimeter is fitted with an accuracy of 0.05 mm.

The altimeter can move through the length and width of the channel.

C) Laboratory models

This study uses 30 laboratory models. Due to the constraints in channel width and to avoid excessive small laboratory models, all models are made as a single cycle. The models used in plan-form are V-shaped. Tables 1 and 2 show specifications of all laboratory models used by a 60cm weir with a 3cm×4cm labyrinth and a 90cm weir with a 9cm×12cm labyrinth, respectively. All models are installed at almost the middle of the lab channel with fully developed flow and pretty smooth water flow at upstream and without small surface wave.

As Table 1 and 2 specify, this study investigates triangular-shaped labyrinth weirs with a fixed height of 17cm, a wall thickness of 0.7 cm, and wing lengths of 30, 60 and 90 cm having labyrinths with three different heights (3, 6, and 9cm) for 7 various discharges with overall 210 samples, height of 17 cm, and wall thickness of 0.7cm located at a flume channel with 7 different discharges is also investigated to be compared with labyrinth weirs. Weir cycles are attached to the flume floor by double sided glue and silicone glue are used for sealing.

Table 2. For a labyrinth with 9 cm height and 8 cm width in the wing in a 90 cm triangular weir

Q (Lir/s) Water height over the weir H(cm) Weir heigh t P(cm) H/P Cd Test No. 50 / 4 52 ./ 9 047 / 0 029 / 0 1 80 / 5 58 / 0 9 052 / 0 0311 / 0 2 7 72 / 0 9 065 / 0 0373 / 0 3 5 / 14 8 / 1 9 163 / 0 098 / 0 4 19 8 / 2 9 254 / 0 102 / 0 5 2 / 20 4 / 3 9 309 / 0 112 / 0 6 23 5 / 4 9 409 / 0 15 / 0 7

D) Since this study is based on the chart comparison, charts 1, 2, 3, 4, 5 and 6 show Cd variation versus H/P for 30, 60 and 90 cm triangle weirs with various labyrinths and widths.

Q(Lir/s ) Water height over the weir

(4)

Chart1. A chart comparison between 30, 60 and 90 cm weirs with a labyrinth with 12 cm width and height of 3 cm.

Chart2. A chart comparison between 30, 60 and 90 cm weirs with a labyrinth with 12 cm width and height of 6 cm.

The comparison of two weir models with lengths of 30, 60 and 90 cm, width of 12 cm and labyrinth heights of 3 and 6 cm is presented. As obvious, the discharge coefficient is greater for 30 cm weirs than 60 cm ones and for 60 cm weirs than 90 cm ones, and as the height of labyrinth increases, the discharge coefficient increases.

Chart3. A chart comparison for 90 cm weirs with a labyrinth with 4 cm width and height of 3,6, and 9 cm.

Chart4. A chart comparison for 60 cm weirs with a labyrinth with 4 cm width and height of 3, 6, and 9 cm. The above charts indicate that as the labyrinth height increases, and the discharge coefficient increases and has the minimum value for the case where there is no labyrinth.

Chart5. A chart comparison between 30, 60 and 90 cm weirs with a labyrinth with 4 cm width

The above chart, which corresponds to a labyrinth with width and height of 5 and 4 cm for weirs with various lengths, indicates that as the labyrinth height increases, the discharge coefficient is increased proportionally.

(5)

As the chart comparison for 60 cm weirs with labyrinth widths of 4, 8 and 12 cm shows, at smaller widths, the discharge coefficient is higher.

E) Discharge Coefficient

In above charts, the discharge coefficient is calculated using the following equation [1, 11, 12, and 19]:

=

* Eq. 1

Where

= discharge coefficient; Q = flow rate (m3/s);

L = effective length of the crest (m);

= total hydraulic load (m), i.e. total static and dynamic load;

g = acceleration of gravity (m/s2)

3. RESULTS AND DISCUSSION

The results obtained after creating new labyrinths in the wing of polyhedral triangular-shaped plan-form weirs show that in simple labyrinth weirs, as the length of weir wings increased, the discharge coefficient decreased, i.e. the discharge coefficient was greater for weirs with shorter wings.

Creating deeper labyrinths in the wings also increased the discharge coefficient and the shorter the weirs were, this increase was more significant. Increasing the width of the labyrinth had no desired effect on the discharge coefficient and is smaller widths, the discharge coefficient was higher. The results also indicate that as discharge increased, the discharge coefficient in weirs with labyrinths in wings was increased to reach a Max point and then started to decline.

REFERENCES

1. Bayat, h., (2001). “Investigating the effect of blade cleaving the water on aeration of labyrinth weirs”, 3rd Iranian Hydraulic Conference.

2. Mehrani, S., (2007). “Analytical study of design methods for labyrinth weirs”, 1st Conference of Dams and Hydraulic Structures in Iran, Islamic Azad University of Karaj. 3. Shenavaei, H., and Ghodsian, M., (2001). “The

effect of crest shape on the discharge coefficient in triangular-shape plan-form

overflows labyrinth weirs”, International Conference on Hydraulic Structures, Kerman. 4. Roshan Z.M., A.R, (2000). “Studying the

polyhedral weirs available at irrigation networks in Neku-Abad, Abshar and Rodasht and comparing their performance using relations derived from laboratory models”. Master's thesis, Irrigation Department, Technology University of Esfahan.

5. cassidy,j.j,c.A.gardner and R.T.peacok.1985.

Boardman labyring crest.

ASCE,J.hyd.Eng.111(3):247255.

6. Darvas,L.A.1971.Performance and design of labyrinth weirs.ASCE,J.Hyd.Eng.97(8):1246-1251.

7. Hay,N.and G. Taylor.1970. performance and design of labyrinth weirs ASCE,J.Hyd.Eng.96(11):2337-2357.

8. Hay,N.and G. Taylor.1972. performance and design of labyrinth weirs. ASCE, j.Hyd. Eng. 96(4): 70811-711

9. Hinchliff, D. L. and K. L. Hostun.1984. hydraulic design and application of labyrinth spillways. Prc. USCOLD Lecture on Dam Safety and Rehabilition, USCOLD, Denver, Colorado.

10.Houston, k. L. 1982. Hydraulic model study of the Ute Dam labyrinth spillway. Rep. No GR-82-7, Bureau of Reclation, Denver, Colorado. 11.Houston, k. l. 1983. Hydraulic model study of

Hyrum auxiliary Labyrinth spillway. Rep. No. GR- 82-13, Bureau of Reclation, Denver, Colorado.

12.Landlekofer, H. and G. Rouve.1975.Disharge over polygonal weirs. ACSE, J. Hyd. Div. 101(3):385-401.

13.Lux, F.1984. Disharge characteristics of labyrinth weirs. Proc.ASCE Hydr. Div of labyrinth weirs. Proc.ASCE Hydr. Div. specialty conf., ACSE, NewYork.

14.Lux, F. and D. L. Hinchliff. 1985. Design and construction of labyrinth spillway Congress of ICOLD,Lausanne, Switzerland, pp. 249-274 15.Tullis, j.p., N. Amanian and D.Waldron.

1995.Design of labyrinth spillways. ASCE, J. Hyd. Eng. 121(3):247-255

Imagem

Figure 1 (a, b) shows sample weir models used in this  study.
Table  2.  For  a  labyrinth  with  9   cm  height  and  8   cm  width in the wing in a 90 cm triangular weir

Referências

Documentos relacionados

A "questão social" contemporânea, chamada erroneamente de "nova questão social", advém dessas profundas modificações nos padrões de produção, de

We also suggest that ​MIR has its origin from non coding sequences also found in common ancestors to species that harbor AA genomes (i.e., species with a similar genomic

This study aimed to estimate live weight, the length and the width of wing and abdomen and the length, the width and the height of thorax in newly emerged Africanized honeybee

Já as CIES devem funcionar como instâncias interinstitucionais e regionais para a cogestão dessa política, orientadas pelo plano de ação regional para a área

As doenças mais frequentes com localização na cabeça dos coelhos são a doença dentária adquirida, os abcessos dentários mandibulares ou maxilares, a otite interna e o empiema da

Neste estudo, verifica-se que o raciocínio segue valores seme- lhantes aos padrões para alunos que frequentam o 9º ano de escola- ridade (Almeida; Lemos, 2008), assim como

Este artigo discute o filme Voar é com os pássaros (1971) do diretor norte-americano Robert Altman fazendo uma reflexão sobre as confluências entre as inovações da geração de

Para determinar o teor em água, a fonte emite neutrões, quer a partir da superfície do terreno (“transmissão indireta”), quer a partir do interior do mesmo