• Nenhum resultado encontrado

COMPARISON OF THE SEMI-PARAMETRIC NAA WITH INAA TO DETERMINE MAJOR TRACE ELEMENTS IN SERUM FOR CLINICAL PRACTICE L.C. Oliveira

N/A
N/A
Protected

Academic year: 2021

Share "COMPARISON OF THE SEMI-PARAMETRIC NAA WITH INAA TO DETERMINE MAJOR TRACE ELEMENTS IN SERUM FOR CLINICAL PRACTICE L.C. Oliveira"

Copied!
1
0
0

Texto

(1)

COMPARISON OF THE SEMI-PARAMETRIC NAA WITH INAA TO DETERMINE MAJOR TRACE ELEMENTS IN SERUM FOR CLINICAL PRACTICE

L.C. Oliveira1, C.B. Zamboni1*, L. Kovcas1, J.A.G. de Medeiros 1, M.R Azevedo2

1 Instituto de Pesquisas Energéticas e Nucleares -IPEN /CNEN-SP Av. Professor Lineu Prestes 2242

05508-000 São Paulo, SP- Brasil czamboni@ipen.br

2Universidade Santo Amaro - UNISA R. Professor Enéas de Siqueira Neto 340

04829-300, São Paulo, SP -Brasil

The semi-parametric neutron activation analysis (a variant of k0 – method) and the instrumental neutron activation analysis techniques were applied for evaluation of some elements’ concentrations of clinical relevancy (Ca, Cl, K and Na) in serum samples of human being. The serum samples from 20 volunteers (male and female, age between 18 and 65 years and above 50 kg.) were prepared by dropping convenient aliquot (200µl of serum) onto Whatman filter paper. In the semi-parametric procedure gold foils was used for the measurement of thermal flux distribution and, in the comparative procedure the reference material from the National Institute of Public Health - Québec (ICP02-05) was used. The standard was prepared by following the same procedure (aliquot of 200µl spread in filter paper) and irradiated with the serum sample. The irradiation was performed in a pneumatic station of the IEA-R1 nuclear reactor at IPEN/SP (2-4MW, pool type, thermal neutron flux of ~10 12 n.cm-2s-1) using an irradiation time of 3 minutes. Considering that these techniques are not destructive the same serum sample was used for both analyses. A comparison with the conventional analyses (Ca by Colorimetry; Cl by Titrymetry; K and Na by Ion Specific Electrode) was performed permitting a discussion about advantages and disadvantages of using each method.

Financial Support: CNPq and CNEN

Referências

Documentos relacionados

Neutron Activation Analysis technique (NAA) has been applied to determine some element concentrations in saliva samples of tick Amblyomma cajennense specie aiming to identify

Instrumental neutron activation analysis was applied for the determination of trace elements in Canoparmelia texana species collected in non- polluted areas of Atlantic Forest and

In the last years the semi- parametric Neutron Activation Analysis (NAA), using Au as neutron flux monitor [1] , has been successfully applied by us for investigation of

of raw materials used to manufacture of potteries, in this work Instrumental Neutron Activation Analysis (INAA) was utilized to determine the elemental composition

In this study, neutron activation analysis was applied to determine elements present in plasma and egg yolk samples of the Bothrops jararaca snake species to select elements that

In the present work, instrumental neutron activation analysis (INAA) followed by gamma-ray spectrometry was applied to estimate the concentrations of Cu, Fe, Mn and Zn in hair

Apravad for publication m IEA lerie's m February 1979... Iron was separated by solvent extraction because of the good results previously achieved in extractions carried out with

As part of the process of implementation of the k 0 -INAA standardization method at the Neutron Activation Laboratory (LAN–IPEN), São Paulo, Brazil, this study