• Nenhum resultado encontrado

(GENERAL PROGRAM) (Proposed to be presented as Oral Communication) Abstracts List of Topics: Radiopharmaceuticals & Radiochemistry & Dosimetry 308. New & Innovative

N/A
N/A
Protected

Academic year: 2022

Share "(GENERAL PROGRAM) (Proposed to be presented as Oral Communication) Abstracts List of Topics: Radiopharmaceuticals & Radiochemistry & Dosimetry 308. New & Innovative"

Copied!
3
0
0

Texto

(1)

(GENERAL PROGRAM)

(Proposed to be presented as Oral Communication)

Abstracts List of Topics:

Radiopharmaceuticals & Radiochemistry & Dosimetry 308. New & Innovative

Abstract Title:

CYCLOTECH – Contribution to Solve the Technetium Shortage by Using Low Energy Medical Cyclotrons

Authors:

L.F. Metello1, Wm. Gelbart2, M. Benedict3, L. Cunha1, R.R. Johnson4

Affiliation:

1 – IsoPor SA, Porto, Portugal & Nuclear Medicine Department of the High Institute for Allied Health Technologies of Porto, Polytechnic Institute of Porto (ESTSP.IPP), VN Gaia, Portugal

2 – Advanced Systems Design (ASD), Garden Bay, Canada

3 - Molecular Diagnostics and Therapeutics Inc. (MDTI), Longmont, Colorado, USA 4 – Best Cyclotrons Systems Inc (BSCI - Team BEST), Ottawa, Canada and University of British Columbia, Vancouver, Canada

(2)

Abstract Text:

This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material.

This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented.

Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future.

The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols.

To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies.

On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents.

Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.

(3)

Foi decidido que não será apresentada a versão integral deste documento.

Para obtenção de mais informações:

www.nucmedonline.net

cursomedicinanuclear@gmail.com

It has been decided that it would not be shown the entire version of this document.

To obtain more informations:

www.nucmedonline.net

cursomedicinanuclear@gmail.com

Referências

Documentos relacionados

Its well established capabilities to early detection of processes involving functional properties allied to its high sensibility and the actual technical

Diante dos vários estudos mostrando a importância da implementação do diagnóstico diferencial das doenças exantemáticas nos países onde o sarampo e a rubéola estão sob controle,

Comparative study between two distinct methods for attenuation correction and the use of no-attenuation correction for the assessment of relative uptake of 99m Tc-DMSA

Material and Methods: Three distinct Nuclear Medicine images were enlarged 2 and 4 times with the different digital image resizing algorithms (nearest neighbor, bicubic

11. O diretor de informação da RTP pronunciou-se sobre a referida queixa alegando que, assim que recebeu o alerta, se empenhou em visionar a peça, tendo verificado que «não constavam

Nóvoa (2009) defende a ligação entre as dimensões pessoais e profissionais na produção identitária dos professores e, mais ainda, uma profissionalidade docente

Na hipótese dos autos, entre os bens penhorados, a esteira elétrica e o piano de parede não estão abrigados pela impenhorabilidade; a primeira por tratar-se de bem

It will be greatly assisted by the study of the current situation, and in most cases it will be clear from that assessment where changes are possible that would lead to modification