(TECHNOLOGISTS PROGRAM)

(Proposed to be presented as Oral Communication or as a Poster)

Abstracts List of Topics:

Physics & Instrumentation & Data Analysis 102. Image Reconstruction

Abstract Title:

Image upsampling algorithms applied on Nuclear Medicine:

Comparison of hqnx and nxSaI algorithms families with two interpolation algorithms - nearest neighbor and bicubic interpolation

Authors:

F. Nogueira1, M. Matias1, S. Soares1, L. Cunha1, L.F. Metello1

Affiliation:

1 – Nuclear Medicine Department of the High Institute for Allied Health Technologies of Porto, Polytechnic Institute of Porto (ESTSP.IPP), VN Gaia, Portugal

(2)

Abstract Text:

Introduction: Image resizing is a normal feature incorporated into the Nuclear Medicine digital imaging. Upsampling is done by manufacturers to adequately fit more the acquired images on the display screen and it is applied when there is a need to increase - or decrease - the total number of pixels. This paper pretends to compare the

“hqnx” and the “nxSaI” magnification algorithms with two interpolation algorithms –

“nearest neighbor” and “bicubic interpolation” – in the image upsampling operations.

Material and Methods: Three distinct Nuclear Medicine images were enlarged 2 and 4 times with the different digital image resizing algorithms (nearest neighbor, bicubic interpolation nxSaI and hqnx). To evaluate the pixel’s changes between the different output images, 3D whole image plot profiles and surface plots were used as an addition to the visual approach in the 4x upsampled images.

Results: In the 2x enlarged images the visual differences were not so noteworthy.

Although, it was clearly noticed that bicubic interpolation presented the best results. In the 4x enlarged images the differences were significant, with the bicubic interpolated images presenting the best results. Hqnx resized images presented better quality than 4xSaI and nearest neighbor interpolated images, however, its intense “halo effect”

affects greatly the definition and boundaries of the image contents.

Conclusion: The hqnx and the nxSaI algorithms were designed for images with clear edges and so its use in Nuclear Medicine images is obviously inadequate. Bicubic interpolation seems, from the algorithms studied, the most suitable and its each day wider applications seem to show it, being assumed as a multi-image type efficient algorithm.

(3)

Foi decidido que não será apresentada a versão integral deste documento.

Para obtenção de mais informações:

www.nucmedonline.net

cursomedicinanuclear@gmail.com

It has been decided that it would not be shown the entire version of this document.

To obtain more informations:

www.nucmedonline.net

cursomedicinanuclear@gmail.com

Referências

Documentos relacionados

No presente estudo a maioria dos idosos apresentou uma satisfação média com o suporte social e não se verificou uma relação entre o estado civil e o suporte

Estas fórmulas são no entanto limitadas uma vez que fazem uma aproximação ao paciente como um sistema fechado, não tendo em conta as perdas e ganhos de água e solutos por outras

Pretendi assim abordar a análise organizacional, nomeadamente a temática da liderança e os seus aspectos essenciais tendo em consideração as transformações que as

Neste estudo verificou-se que, globalmente, a acupunctura auricular obteve um efeito superior ao da acupunctura auricular sham pois, após o respectivo tratamento, houve

The control module (1) has a microcontroller that allows connection to the remaining modules, a timer to help set the time for taking the medicine, a battery for a power supply, a

A título exemplificativo, apresenta-se apresenta se de seguida um ciclo típico de colocação de encomendas e fluxo de mercadorias dorias para um cliente: 1.º Identificação

Tratamento e acompanhamento: A perda de proteína pelo trato gastrointestinal pode ter várias causas, pelo que foram feitos diferentes exames complementares para

Na opinião de Ferland (2006), o brincar representa o desenvolvimento da criança em relação ao saber-fazer e ao saber-ser, ou seja, desenvolve aptidões e atitudes que