CORREÇÃO DO FATOR DE POTÊNCIA POWER FACTOR CORRECTION UNITS

N/A
N/A
Protected

Academic year: 2021

Share "CORREÇÃO DO FATOR DE POTÊNCIA POWER FACTOR CORRECTION UNITS"

Copied!
16
0
0

Texto

(1)
(2)

ÍNDICE

INDEX

SISTEMAS AUTOMÁTICOS C. F. P.

//

1

/

2

/

3

SISTEMAS TIPO 1

//

4

/

5

SISTEMAS TIPO 2

//

6

/

7

SISTEMAS TIPO 3

//

8

/

9

SISTEMAS TIPO 4

//

10

/

11

P. F. C. AUTOMATIC SYSTEMS

//

1

/

2

/

3

TYPE 1 UNITS

//

4

/

5

TYPE 2 UNITS

//

6

/

7

TYPE 3 UNITS

//

8

/

9

TYPE 4 UNITS

//

10

/

11

(3)

MODELO TIPO 1

Dimensões (h) 600 x (l) 450 x (p) 260mm

TYPE 1 MODEL

Dimensions (h) 600 x (w) 450 x (d) 260mm

MODELO TIPO 2

Dimensões (h) 850 x (l) 650 x (p) 260mm

TYPE 2 MODEL

Dimensions (h) 850 x (w) 650 x (d) 260mm

MODELO TIPO 3

Dimensões (h) 1150x (l) 700 x (p) 360mm

TYPE 3 MODEL

Dimensions (h) 1150 x (w) 700 x (d) 360mm

MODELO TIPO 4

Dimensões (h) 1910 x (l) 1100 x (p) 360mm

TYPE 4 MODEL

Dimensions (h) 1910 x (w) 1100 x (d) 360mm

(4)
(5)

P. F. C. AUTOMATIC SYSTEMS

TECHNICAL DATA

Rated Power

15 … 420 kVar

Rated Voltage

440 Vac // Maximum overvoltage 1,1 Un // Maximum overcurrent 1,3 In

Regulator

Varmetric measurents by means of a CT, with 5A secondary (CT not supplied).

Auxiliary Circuits Voltage

400 Vac

Rated Power

Referred to rated voltage and frequency.

Rated Frequency

50 – 60 Hz

Isolating main Switch

RP1 models, by three-pole circuit breaker // Other models by three-pole isolator switch with door interlocking block.

Wiring

The internal cables are self-extinguishing N07VK CEI 20-22 type.

The auxiliary circuits are identified according to the electrical drawings.

Cabinet

Metallic for wall and/or floor installation. Modular in 15mm sheet-metal protected against corrosion by phosphating treatment.

Epossidic dust painted (RAL 7035 color) Front door with locking system. Other colors by request.

User Manual support behind the door.

Protection Degree

IP21 open door // IP31 closed door// IK 08

Ventilation

Natural (or forced by request, and depending of the environmental conditions).

Installation

Indoor

Montage

Wall or Floor.

Operating Temperature Range

-20 / +50 ºC

Cable entrances

By the cabinet top when wall mounted in the RP1/ RP2/ and RP3 models.

By the footer when floor mounted in the RP2/ RP3/ and RP4 models.

Contactors

Each bank of capacitors is controlled by specific three-pole contactors, for capacitive loads. To limit the inrush current peaks, each contactor is equipped with insertion resistors. Rated voltage of the auxiliary circuits 400Vac, 50Hz.

Protections

Each bank of capacitors is protected by a 3P magneto-thermal circuit breaker (RP1 and RP2 models), or by a set of three-pole fuses NH00 type with high breaking capacity. The auxiliary circuits are also protected by 10x38 fuses.

Capacitors

LIFASE brand, POLIMET type, cylindrical, three-phase capacitors, self-healing metalized polypropylene film according to the CEI standards, equipped with overpre-ssure device and discharge resistor.

Capacitance tolerance -5% to +10% Dielectric losses < 0,4 W/kVar

Capacitors CEI EN 60831-1/2; IEC 831-1/2 REFERENCE STANDARDS LV Directive 73/23 EEC (93/68) Equipment

CEI EN 60439-81; IEC 439-1 // CIS EN 61921-1

Protection degree

For IP40 to IP54

OTHER OPTIONS (BY REQUEST)

Protections

Protection and control instruments against overvoltage and overcurrent due to harmonic distortions.

Note: Other models, different features, level of tension and frequencies available by request.

ReativaPlus reserves the right to modify the above-mentioned features and dimensions without previous notice.

(6)

4

(7)

MODELOS TIPO 1

//

TYPE 1 MODELS

Model Power (kVar)/440 V 50HzRated Voltage (V)Rated Current In (A)Power (kVar)/ 400 V 50HzPower banks (kVar) 440 VSwitching steps Cabinet Dim h x w x d mmRegulator Type Main Switch by MCB (A)Power Feed cable (mm2)

DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3

(8)

MODELOS TIPO 2

//

TYPE 2 MODELS

(9)

DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3

MODELOS TIPO 2

//

TYPE 2 MODELS

Model Power (kVar)/440 V 50HzRated Voltage (V)Rated Current In (A)Power (kVar)/ 400 V 50HzPower banks (kVar) 440 VSwitching steps Cabinet Dim h x w x d mmRegulator TypeMain Switch (A)Power Feed cable (mm2)

(10)

8

(11)

MODELOS TIPO 3

//

TYPE 3 MODELS

* Dimensions without footer – footer H = 150mm

NOTE: the unit equipped with footer has an extra cost of more 80€

Model Power (kVar)/440 V 50HzRated Voltage (V)Rated Current In (A)Power (kVar)/ 400 V 50HzPower banks (kVar) 440 VSwitching steps Cabinet Dim h x w x d mmRegulator TypeMain Switch (A)Power Feed cable (mm2)

DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3 DCRL3

(12)

10

(13)

MODELOS TIPO 4

//

TYPE 4 MODELS

NOTE: At request: higher powers, other models or different features.

Model Power (kVar)/440 V 50HzRated Voltage (V)Rated Current In (A)Power (kVar)/ 400 V 50Hz Power banks (kVar) 440 VSwitching steps Cabinet Dim h x w x d mmRegulator TypeMain Switch (A)Cable (mm2)

PREÇOS SOB CONSULTA. PRICES ON REQUEST.

DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRL5 DCRK12 DCRK12 DCRJ12

(14)

November, 2014

NOTAS

//

NOTES

Reativa Plus reserves the right to change prices presented in this table. Prices exclude VAT. Statutory rate in force is to be added to all presented prices.

Products and materials presented in this document are prone to evolution, both on technical and aesthetics, and operation plans. Its description can not be considered, at any case, as of having a contractual aspect. Therefore Reativa Plus is only liable for the information provided after confirmation by our services.

A Reativa Plus reserva o direito de alterar os preços constantes da presente tabela.

Aos preços indicados acresce o Imposto sobre o Valor Acrescentado (I.V.A.) à taxa legal em vigor.

OS produtos e materiais apresentados neste documento são suscetíveis de evolução, tanto nos planos da técnica e da estética, como no plano da utilização. A sua descrição não pode, em caso algum, ser considerada como tendo um aspeto contratual. Assim, só nos responsabilizamos pelas informações dadas após confirmação pelos nossos serviços,

(15)

CONSULTE-NOS. TEMOS A SOLUÇÃO!

CONTACT US. WE HAVE THE SOLUTION!

TRANSFORMADOR Transformer

Energia Ativa / Active Power

EQUIPAMENTOS DA INSTALAÇÃO Plant Equipments

Energia Reativa / Reactive Power

BATERIA DE CONDENSADOR Capacitor bank

ENERGIA ATIVA

Active Power (kW)

ENERGIA TOTAL

Total Power (kVA)

(16)

Referências

Documentos relacionados

Assim como em outras comunidades atendidas pelo AfroReggae, identificamos que as áreas mais pobres e de maiores privações estão geograficamente localizadas nas áreas de

Este relatório relata as vivências experimentadas durante o estágio curricular, realizado na Farmácia S.Miguel, bem como todas as atividades/formações realizadas

JORGE. Hade poupara-lhe esse iíicommòdo. OS MESMOS, ELISA E GOMES. Não é uma visita, Sr. Jorge, que viemos fazer-lhe, minha filha e eu. Não é uma visita, não. E' uma romaria,

Na mesma linha de pensamento, Leff (2009) enfatiza que os indivíduos precisam ser conscientizados e, para que ocorra tomada de consciência quanto ao uso dos

As previsões do consumo de energia elétrica são essenciais para o planejamento da expansão do Setor Elétrico Brasileiro, pois têm impacto direto nas decisões de planejamento

Consideramos ainda, na esteira de Manita, Ribeiro e Peixoto (2009), que a violência no namoro não se circunscreve apenas à violência física, mas também.. envolve abusos psicológicos

Ao final do estudo, foram então realizadas duas dinâmicas com o grupo, uma por encontro, com o objetivo de elevar a autoestima desses adolescentes, a fim de que se valorizem e

Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for