• Nenhum resultado encontrado

Arq. Bras. Cardiol. vol.78 número1

N/A
N/A
Protected

Academic year: 2018

Share "Arq. Bras. Cardiol. vol.78 número1"

Copied!
7
0
0

Texto

(1)

8 3 8 3 8 3 8 3 8 3

Heart Institute of Hospital das Clínicas - FMUSP - São Paulo and University Hospital - HURNP/UEL - Londrina

Mailing address: Manoel F. Canesin - Rua Piauí, 701- 86020-320 - Londrina, PR Brazil - E-mail: mcanesin@cardiol.br

Objective - To evaluate the relationship between

24-ho-ur ambulatory arterial blood press24-ho-ure monitoring and the prognosis of patients with advanced congestive heart failure.

Methods - We studied 38 patients with NYHA

functio-nal class IV congestive heart failure, and afunctio-nalyzed left ventricular ejection fraction, diastolic diameter, and am-bulatory blood pressure monitoring data.

Results – Twelve deaths occurred. Left ventricular

ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pres-sure sleep decrements (dip) and patients with mean blood

pressure dip 6mmHg had longer survival (p=0.04 and

p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 ti-mes more likely to die than those with SBP 105 mmHg

Conclusion - Ambulatory blood pressure monitoring

appears to be a useful method for evaluating patients with congestive heart failure.

Key words: heart failure, prognosis, blood pressure am-bulatory monitorization

Arq Bras Cardiol, volume 78 (nº 1), 83-9, 2002

Manoel F. Canesi n, Dant e Gi or gi , Múci o T. de Ol i vei r a Jr., Maur íci o Waj ngar t en, Al f r edo J. Mansur, José Ant oni o F. Ram i r es, Ant oni o Car l os Per ei r a Bar r et t o

São Paulo, SP - Londrina, PR - Brazil

Ambulatory Blood Pressure Monitoring of Patients with

Heart Failure. A New Prognosis Marker

Congestive heart failure is a complex syndrome with various clinical presentations each having different etio-logical and pathophysioetio-logical characteristics. The particu-lar clinical variation is related to the great number of signs and symptoms, to the myocardial dysfunction, and to the neurohormonal activation that each patient experiences. With such variability, it is difficult to correctly establish the severity and prognosis of congestive heart failure.

Despite the study of the therapeutic value of medica-tions, large clinical trials have identified hemodynamic, neurohormonal, immunological, and inflammatory altera-tions 1 that have distinct prognostic value according to the

evolutionary stage of the heart failure, characterizing this syndrome as a complex disease.

Among the countless parameters used to evaluate the patients’ evolution, 2 prognostic indexes are considered of great importance: New York Heart Association (NYHA) functional class 2 and left ventricular ejection fraction 3. Due

to the ease of attainment and their discriminatory powers, these indexes are currently the most frequently used for stratifying patients’ risk during different evolutionary pha-ses of the disease. Often, however, due to the subjectivity of functional class evaluation or to failure to evaluate left ventricular ejection fraction, it is not possible to determine the evolutionary difference of advanced congestive heart failure patients with these indexes. Prognostic indexes, such as systolic volume and final left ventricle diastolic pressure 4, are also used as criteria for indication of heart

transplant in patients in more advanced stages of the disea-se. However, often they do not allow differentiation of pati-ents with a worse evolution. Possibly because these indexes are evaluated only once, difficulties still exist in determining the correct prognosis of patients with advanced congestive heart failure. In some studies, left ventricular ejection frac-tion did not correlate with survival time in advanced con-gestive heart failure patients 5 and, probably, the lack of

(2)

8 4 8 4 8 4 8 4 8 4

ventricular ejection fraction of patients with advanced con-gestive heart failure 6. Along the same line of reasoning,

other factors, such as clinical signs and symptoms, bioche-mical, hematological, and neurohormonal parameters eva-luated at rest, do not predict a better prognosis for advan-ced congestive heart failure.

Some studies have already analyzed the role of dyna-mic evaluation in patients with advanced congestive heart failure. Maximum oxygen consumption by ergo-spirometric testing 7, measurement of maximum heart rate on effort 3,

6-minute walk testing 8, stress echocardiography 9, and

maxi-mum oxygen consumption7 are being used to evaluate these

patients’ prognoses. Other dynamic variables carried out for longer periods may be used to evaluate congestive heart failure patients. Alterations in the blood pressure levels and their variability over 24 hours, evaluated by 24-hour ambu-latory blood pressure monitoring 10, have not yet provided

criteria for determining prognostic indexes, especially in advanced congestive heart failure patients.

Due to the difficulty of determining the prognosis of patients with advanced congestive heart failure with greater precision through rest methods, new methods of evaluati-on, applicable to most patients, are still needed. The asses-sment of methods for dynamic evaluation may provide a better definition of prognosis and of treatment for these pa-tients. We used ambulatory blood pressure monitoring as a method of dynamic evaluation over 24 hours to assess blo-od pressure behavior in a group of patients with advanced congestive heart failure, and we tried to establish a correla-tion between ambulatory blood pressure monitoring varia-bles and these patients’ prognoses.

Methods

Forty-three patients admitted to the emergency room with a clinical diagnosis of congestive heart failure functio-nal class IV (NYHA) were prospectively studied. At the time of admission, they did not have primary valve diseases ca-pable of correction, congenital heart disease, features of acute coronary ischemia, or surgery for coronary revascula-rization for at least 6 months, or carditis, endocarditis, and pericarditis.

All patients received classical treatment for severe, chronic arrhythmic congestive heart failure, which included rest, a low-salt diet, and restriction of water intake to 800 to 1000mL/day. Medication therapy included digitalis adminis-tered orally to 39 patients, 0.25mg/day of digoxin, and in 4 patients 0.100mg/day of digoxin. Diuretic therapy included use of snare diuretics (furosemide, 40 to 240mg/day) adjus-ted according to patients’ diuretic response. Thiazide diu-retics (hydrochlorothiazide, 25 or 50mg/day) were prescri-bed to 11 patients and spironolactone to four (25 or 50mg/ day). Angiotensin-converting enzyme inhibitors used were captopril (50 to 100mg/day) in 33 patients and enalapril (5 to 20mg/day) in 4 patients. In 6 instances of contraindication or undesirable side effects to angiotensin-converting enzy-me inhibitors, hydralazine (75 or 100 mg/day) was used in

conjunction with isosorbide dinitrate (60 to 120mg/day) as a vasodilator option. Nine patients had signs of low heart debt associated with persistent congestive manifestations, it being necessary to use inotropic support with dobutami-ne, 5 to 10mg/kg/min, iv, maintaining the therapeutic schedule and removing dobutamine after clinical stabiliza-tion. After clinical compensation of the acute phase, pati-ents were informed of the study, and were asked to give writ-ten consent to participate.

After hemodynamic stabilization and reduction in con-gestive status, all 43 patients were placed on a 24-hour am-bulatory blood pressure monitoring and echocardiographic evaluation of left ventricular ejection fraction and left ventri-cular diastolic diameter. After hospital discharge, patients were followed up as outpatients. All patients were contac-ted, within a minimum observation period of 6 months (28 weeks). The date of death, when it occurred, was confirmed by the death certificate or by first degree relatives’ informa-tion. None of the patients underwent heart transplantation or any other surgical procedure during the study.

Patients were predominantly male, 29 (67%). Mean age of the group was 53.5±13.0 years, with the youngest being 21 years old and the oldest being 76. Most of the patients, 37 (86%), were over 40 years old, and only 6 (14%) were between 21 and 39 years of age. The onset of congestive heart failure symptoms was reported on average 41 months before inclu-sion in the study, varying from 0.5 to 240 months of evolution. Most patients reported the first signs of the disease between 1 and 5 years before hospitalization. Hypertensive cardiomyo-pathy was the cause of congestive heart failure in 16 (37%) pa-tients; idiopathic dilated cardiomyopathy in 14 (32%) papa-tients; chagasic cardiomyopathy in 8 (18%) patients, and ischemic cardiomyopathy in 5 patients (13%).

After congestive heart failure compensation was esta-blished, patients underwent ambulatory blood pressure mo-nitoring, by the oscillometric principle using the 90207 Spa-ceLabs monitor (SpaSpa-ceLabs Inc., WA, USA). Data analysis was performed using 90121 SpaceLabs report managing software installed in a personal computer. Five patients either did not undergo the examination or correct data in-terpretation was not possible. Two refused monitor installa-tion or its maintenance; 1 had high-response atrial fibril-lation, 1 had atrial tachycardia, and 1 patient had ventricular extrasystoles and non-sustained ventricular tachycardia episodes difficult to control.

(3)

8 5 8 5 8 5 8 5 8 5

Analysis of data collected from 38 patients, adjusted to the waking and sleeping periods according to patients’ reports: included: mean 24-hour systolic blood pressure (SBP24), mean 24-hour diastolic blood pressure (DBP24h), mean 24-hour mean blood pressure (MBP24), mean waking systolic blood pressure (SBPw), mean waking diastolic blo-od pressure (DBPw), mean waking bloblo-od pressure (MBPw), mean sleeping systolic blood pressure (SBPs), mean sle-eping diastolic blood pressure (DBPs), and mean blood pressure during sleep (MBPs). Blood pressure variability for the period and the decrements in SBPw and SBPs SBP), DBPw and DBPs (dipDBP), MBPw and MBPs (dip-MBP) were also calculated.

Initially, all variables were descriptively analyzed. Continuum variables were analyzed by observation of mini-mum and maximini-mum values and by calculation of means and standard deviations. For classificatory variables, absolute and relative frequencies were calculated. Correlation between variables was performed with Pearson’s correla-tion coeficient 11. Association between each variable

mea-sured and death was analyzed with Student’s t test 11 for

pa-rametric variables and the chi-square test or Fisher’s exact test for classificatory variables. To evaluate the association of variables together with death, a multiple logistic regres-sion with a process of stepwise selection was used 11. To

study the patient’s time of survival, the Kaplan-Meier survi-val curves and Cox’s regression model for analysis of joint variables were used. The level of significance was set at 5%.

Results

Echocardiographic measurement of left ventricle diastolic diameter varied from 56 to 92mm, with a mean ± S.D. of 72.2±7.8mm. Thirty patients (70%) had an average diameter of 70mm or more. Left ventricular ejection fraction determined by echocardiography varied from 18 to 52%, mean 35.2±7.3%. Values ≤35% were observed in 22 (51%) patients.

Means and standard deviations of patients’ blood pressure measurements throughout the period were: SBP24, 108.2±13.4mmHg; DBP24, 72.2±8.1mmHg; and MBP24, 84.9±8.6mmHg. Means and standard deviations of blood pressure during waking periods (SBPw, 109.0±13mmHg; DBPw, 72.2±7.9mmHg; and MBPw, 85.5±8.4mmHg) were higher when compared to with pressure averages and stan-dard deviations throughout the sleeping period [SBPs, 106.1±15.5mmHg; DBPs, 70.5±9.6mmHg; MBPs, 83.3±10.3m m Hg, (p=0.004, p=0.005, and p=0.009, respectively)]. Means and standard deviations of the night decrements in patients throughout the period were: dipSBP, 2.8±5.6mmHg; dipDBP, 2.2±4.6mmHg; and dipMBP, 2.1±4.6mmHg with a drop of 2.6%, 3.0%, and 2.5% during the sleeping period compared with that in the respective waking period.

A statistical correlation existed between the measures of blood pressure and left ventricular ejection fraction or with left ventricular diastolic diameter, evaluated by 24-hour ambulatory blood pressure monitoring (Table I). However,

no correlation existed between night decrements and echocardiographically evaluated measures.

After a period of at least 28 weeks (6 months), 12 (31%) deaths, 11 (92%) men and one woman (8%), were reported by phone contact, telegram, or verification of medical charts. Patients underwent an average follow-up of 35 weeks (7.5 months), varying from 7 to 76 weeks. The 12 deaths were attributable to cardiopathy, with 9 (75%) deaths in the hospital due to the disease’s evolvement and 3 (25%) sudden deaths at home, reported by relatives.

Mean and standard deviation of left ventricular ejec-tion fracejec-tion (37±7%) of the live patients (32 patients) were higher than those (32±6%) before death in patients (12 patients) who died (p=0.02). We also observed a tendency toward smaller left ventricular diastolic diameter (7.1±0.8%) in the live patients compared with that in the deceased ones (7.6±0.6%) (p=0.05). The Kaplan-Meier and log-rank nonparametric analyses indicated that both left ventricular ejection fraction and diastolic diameter were not significant predictors of the survival time of the patients under study.

Means and standard deviations of the average blood pressure of the live patients (26 patients) (SBP24, 111.5± 13.1mmHg; SBPv, 111.9±12.9mmHg; and SBPs, 110.5± 14.4mmHg) were higher than those of the deceased patients (12 patients) before death [SBP24, 100±11mmHg; SBPv, 101.6±10.4mmHg; and SBPs, 95.4±13.1mmHg (p=0.01, p=0.02, and p=0.005, respectively)]. Figure 1 shows the comparison between the 24-hour blood pressure curves of living and deceased patients. The mean and standard devia-tion of the live patients’ MBPs (85.6±9.2mmHg) was higher than those of the patients who died (77.6±11.0mmHg) (p=0.02), dipSBP (1.4±5.7mmHg), dipDBP (1.1±4.8mmHg), and dipMBP (1.0±4.9mmHg) of the live patients were lower than the dipSBP (6.1±4.0mmHg), dipDBP (4.8±3.2mmHg), and dipMBP (5.0±3.3mmHg) of the deceased patients (p=0.01, p=0.02, and p=0.01, respectively) (Fig. 2). In the curves of mean systolic blood pressure measured hourly, the lower dipSBP in the live patients is noticeable. Kaplan-Meier and log-rank tests of nonparametric analysis revealed that SBP24, SBPw, SBPs, and MBPs were significant for the estimation of survival time of the study patients. Analysis of these parameters as classificatory variables revealed dif-ferences in survival time. The groups of patients with SBP24 (n=22), SBPw (n=23), and SBPs (n=23) ≥105mmHg had a longer survival time than patients with SBP24 (n=16), SBPw

Table I - Correlation between 24-hour, waking and sleeping systolic blood pressure (SBP24, SBPw, SBPs) with left ventricular ejection fraction (LVEF) and diastolic diameter (LVDD) (Pearson’s

correlation coefficient)

LVEF LVDD

Parameter r P r p

(4)

8 6 8 6 8 6 8 6 8 6

(n=15), and SBPs (n=15) <105mmHg (p=0.002, p=0.01, and p=0.0007, respectively) (Figs. 3 and 4). The group of patients with MBPs (n=23) ≥80mmHg, when compared with patients with MBPs (n=15) <80mmHg (p=0.0003) also had a longer survival time. The Kaplan-Meier and log-rank test for nonparametric analysis also revealed that dipSBP, dipDBP, and dipMBP were significant for estimation of sur-vival time of the study patients. Analysis of these parame-ters as classificatory variables revealed the tendency to-ward differences in the longer survival time in the group of patients with dipSBP ≤6mmHg (n=28), compared with that in patients with dipSBP >6mmHg (n=10) (p=0.06). Patients with dipDBP ≤5mmHg and patients with dipMBP ≤6mmHg had longer survival times when compared with patients with dipDBP >5mmHg (p=0.04) and dipMBP >6mmHg (p=0.01) (Fig. 5). The other blood pressure variables were significant as predictors of survival time in the patients studied accor-ding to the nonparametric analysis with Kaplan-Meier and log-rank tests. In the multivariate analysis, the variables wi-th higher statistical power (p<0.10) were selected for wi-the univariate analysis: age, sex, etiology, left ventricle ejection fraction, left ventricle diastolic diameter, SBPw and SBPs; SBPs was the only variable selected with an odds ratio of 7.61 (IC: 1.56; 37.04) (p=0.01). Patients who had mean sleep systolic blood pressures <105mmHg were 7.6 times more li-kely to die than patients with means ≥105mmHg. In the Cox’s regression model multivariate analysis, the variables associated with survival time were SBP24 (p=0.07), SBPs (p=0.002), SBPw (p=0.01), and MBPs (p=0.01).

Discussion

The purpose of the present study was to examine whether 24-hour dynamic evaluation through ambulatory blood pressure monitoring adds advantages to the study of patients with advanced congestive failure.

Several methods of direct evaluation of myocardial danger ay help in the prognostic evaluation f patients with advanced congestive heart failure. Among them are echo-cardiography; nuclear medicine techniques, such as radioi-sotopic ventriculography and myocardial perfusion scinti-graphy; cardiac catheterization, and nuclear magnetic reso-nance. All these methods have advantages and limitations for myocardial anatomical-functional and prognostic evaluation of patients with advanced congestive heart failure. Analysis of myocardial impairment ith echo-Doppler cardiography is one of the most used because it is a noninvasive examination, inexpensive, and easy to perform. Left ventricular ejection fraction and diastolic diameter used in the present sample are variables routinely used in the anatomical-functional and prognostic evaluation of patients with congestive heart failure, but nonetheless, are subject to criticism 12-16. In clinical

experience, it is evident that patients with larger ventricular dilation and smaller ejection fraction have a worse prognosis; however, it is not uncommon for patients with important compromise to have irrelevant clinical repercussion over a long evolutionary period. Although in some studies, such as ours,

SBP24 (111±13) dipSBP (1,4±5,7) (n=27)

(n=11) p=0,01

p=0,01 SBP24 (111±13)

dipSBP (1,4±5,7) S B P

(mmhg)

Time

Fig. 1 - Comparative time-course of 24-hour systolic blood pressure (SBP) in mm Hg between living (n=27) and deceased (n=11) patients in the sample.

Survival curve - 24 hours SBP

Time (in weeks) Estimate

survival probability

mmHg (n=22)

mmHg (n=16)

Fig. 2 - Survival curves of patients with mean 24-hour systolic blood pres-sure (SBP24) >105mmHg (n=22) and of patients with SBP24 <105mmHg (n=16).

Alive Dead

Estimate survival probability

mmHg (n=23)

mmHg (n=15)

Fig. 3 - Survival curves of patients with mean waking systolic blood pressure (SBPw) >105mmHg (n=23) and of patients with SBPw <105mmHg (n=15).

Survival curve - waking SBP

Time (in weeks)

Estimate survival probability

mmHg (n=23) mmHg (n=15)

Fig. 4 - Survival curves of patients with mean sleep systolic blood pressure (SBPs) >105mmHg (n=23) and of patients with SBPs <105mmHg (n=15).

Survival curve - sleep SBP

(5)

8 7 8 7 8 7 8 7 8 7

left ventricle ejection fraction did not show a correlation with the prognosis of patients with severe congestive heart failure 17, it is

important to emphasize that, in other studies, it was cha-racterized as a variable, identifying patients with distinct evolutionary potentials 15,17,18. The studies report that

ven-tricular function indexes less influenced by loading conditions, such as the relation between final systolic pressure (or stress)/ final systolic volume (or diameter), and the relation between ejection fraction (or shortening percentage)/wall final systolic stress, are better mortality predictors than the classical indexes of ejection phase, such as ejection fraction, percentage of shortening of myocardial fiber, and velocity of circumferencial shortening 20. Because results are not always homogenous

and a search continues for more accurate methods of prog-nostic echocardiographic evaluation, dynamic evaluation through stress echocardiography is being used as a better complementary technique. Another form of prognostic evaluation for these patients is nuclear medicine; however, as occurs in echocardiography, factors like hemodynamic volu-me and blood pressure may influence ventricular ejection fraction of patients with advanced congestive heart failure who undergo radioisotopic ventriculography 6.

Currently, several studies are underway that correlate ambulatory blood pressure monitoring with lesions in tar-get organs in hypertensive patients. These studies used left ventricular hypertrophy 20, 21, microalbuminuria 22, retina

al-terations, and cerebrovascular diseases 23 as variables.

Ho-wever, few studies used ambulatory blood pressure moni-toring to investigate congestive heart failure 10,24,25.

Average measurements of systolic and diastolic, 24-hour, waking and sleeping blood pressures in patients with functional class IV congestive heart failure in the present sample were not higher than the normal patterns of ambula-tory blood pressure monitoring. Note that clinically standar-dized normal values of isolated blood pressure measu-rements are not appropriate for ambulatory blood pressure monitoring. Recent population studies have proposed that maximum values of systolic and diastolic blood pressure should be between 119 to 126/75 to 80mmHg 26. With regard

to ambulatory blood pressure monitoring values of conges-tive heart failure patients, Giles et al 10 studied 30 patients

with congestive heart failure, functional class II to IV with a

nonhypertensive cause, and found higher mean 24-hour va-lues of systolic (130.8mmHg) and diastolic (76.5mmHg) pressure, compared to with those in the present sample, which were between 108.2 and 72.2mmHg, respectively. Ho-wever, Borne et al 24 studied 29 patients with congestive

he-art failure, functional class III and IV, excluding patients with hypertensive cardiomyopathy, and found lower sys-tolic, diassys-tolic, 24-hour, waking, and sleeping pressure values than those of our sample. These findings prove that other factors, such as degree of ventricular dysfunction, neurohormonal alterations, and the etiology of cardiomyo-pathy of patients with congestive heart failure, may lead to alterations in pressure levels, evaluated by ambulatory blood pressure monitoring of these patients.

In the analysis of blood pressure variability in the patients studied, means of decrements of systolic, diastolic, and sleeping average blood pressure were reduced, and a drop occurred during sleep of 2.6%, 3.0%, and 2.5% as compared to with the respective measurements during wa-king time. The importance of blood pressure decrements du-ring sleep is still controversial in healthy people and subjects with cardiovascular diseases. Verdecchia et al 27 reported that

hypertensive subjects not having blood pressure sleep de-crements above 10% of the waking period had a more hy-pertrophied left ventricle when compared with patients with decrements during the sleeping period. Evaluating normo-tensive subjects 28, these same authors did not find a

dif-ference in left ventricular mass between subjects with or without blood pressure decrements during sleep.

Regarding congestive heart failure, Borne et al 24 found

a smaller blood pressure and heart rate sleep decrement in patients with congestive heart failure, functional classes III and IV, as compared with a healthy population. The following hypothesis may explain the reduction in blood pressure sleep decrement in congestive heart failure patients. Nocturnal rest results in dispersion of retained liquids, leading to a concomitant increase in central venous pres-sure. In healthy people, the cardiopulmonary baroreflex inhi-bits sympathetic activation and helps decrease blood pressure. Some studies suggest a compromised congestive heart failure baroreflex may cause a reduction in blood pressure sleep decrement 29-32. The finding may also be

re-lated to the increased sympathetic stimulation observed in congestive heart failure 32. During the waking period,

phy-sical activity produces increased stimulation of the sympa-thetic nervous system, both in healthy subjects and in con-gestive heart failure patients. During sleep, this sympathetic activity, which remains stimulated in congestive heart failu-re patients, is inhibited with failu-rest in healthy subjects. This fact possibly justifies also the lack of a decrement in blood pressure during sleep in congestive heart failure patients when compared with that in healthy subjects 25.

Previous studies evaluated blood pressure variability in hypertensive patients through other parameters, such as standard deviation and the variation coefficient of blood pressure measurements 33. Some studies in hypertensive

patients showed that 24-hour blood pressure variations were Estimate

survival

probability mmHg (n=30)

mmHg (n=8)

Fig. 5 - Survival curves of patients with mean blood pressure night decrements (dipMBP) <6mmHg (n=30) and of patients with dipMBP >6mmHg (n=8).

Survival curve - dipMBP

(6)

8 8 8 8 8 8 8 8 8 8

correlated with lesions in target organs 34, but other studies did

not show such a correlation 35. In advanced congestive heart

failure patients, these variables are subject to major alterations due to the influence of several pathophysiological factors of this phase of the disease, limiting data interpretation 36.

Analysis of left ventricle ejection fraction and diastolic diameter showed, respectively, a positive and negative correlation with the following variables of blood pressure measurements: SBP24, SBPw, and SBPs. Left ventricular ejection fraction and diastolic diameter did not show a corre-lation with measurements of systolic, diastolic, and average blood pressure sleep decrement. These results demonstrated that left ventricular ejection fraction and diastolic diameter measured with echocardiography also have a correlation with systolic pressure levels evaluated by 24-hour ambulatory blood pressure monitoring. Caruana et al 36 did not observe a

correlation between SBP24, SBPw, and SBPs with left ventri-cular ejection fraction measured by ventriculography in pati-ents with congestive heart failure, functional class II to IV; ho-wever, they showed a positive correlation of SBP24h standard deviation and blood pressure sleep decrement with left ven-tricular ejection fraction. In a study using functional class II to IV patients, Giles et al 10 observed a negative correlation

betwe-en systolic pressure absolute amplitude and neurohormonal indexes that are markers of congestive heart failure. Canesin et al 25 observed a direct correlation between 24-hour systolic

pressure measured by ambulatory blood pressure monitoring and the quality of life of patients with advanced congestive heart failure. Different findings of correlations between mea-sures of blood pressure and its variability with left ventricular ejection fraction are probably due to the heterogeneous characteristics in the disease’s evolutionary level, etiology, and even the presence of associated diseases in patients with congestive heart failure, which often hinder the selection of patients for such analyses.

Measurements of blood pressure may be correlated with the prognosis of congestive heart failure patients. Pre-vious studies correlated blood pressure with survival time of patients with congestive heart failure. Franciosa et al 37

reported that the isolated blood pressure measurement has a prognostic importance in patients with congestive heart failure. Other authors 38 also demonstrated that higher

va-lues of isolated measurements of average blood pressure in patients with congestive heart failure, functional class II to IV, of different etiologies, are correlated with a better prog-nosis. Ghali et al 39 demonstrated the prognostic role of

iso-lated blood pressure measurement in congestive heart fai-lure patients, where patients with smaller ventricular func-tions and higher systolic and diastolic blood pressures have longer survival time. These authors also observed that the same did not occur in congestive heart failure patients with better ventricular function, demonstrating that measu-rements of blood pressure in different populations of congestive heart failure patients may have different prog-nostic implications. From these studies of isolated blood pressure measurements began the analysis of continuous 24-hour dynamic evaluation of blood pressure.

In congestive heart failure patients, the use of ambula-tory blood pressure monitoring is still limited. Using it in 29

patients with congestive heart failure, functional class III and IV, Borne et al 24 found SBP24h, SBPw, and SBPs values

lower than in the control group. In the present study, univa-riate analysis revealed that the patients who had higher 24-hour, waking, sleeping, and averaged sleeping systolic blood pressure had lower mortality. In the analysis of survi-val time by Kaplan-Meier and log-rank tests, these same blood pressure variables were shown to be significant, de-monstrating longer survival times in patients who had hi-gher pressure levels. The classificatory analysis of blood pressure values showed that patients with mean values

≥105mmHg of SBP24h, SBPw, SBPs, and values ≥80mmHg of MBPs had longer survival times when compared with pa-tients with lower values. Measurements of blood pressure variability evaluated by decrements during the sleep period also showed prognostic importance. The results demons-trated that deceased patients studied exhibited higher dipSBP, dip DBP, and dipMBP before death. Analysis of survival time by Kaplan-Meier and log-rank tests demons-trated, for the first time, that these variables have predictive value for survival time in patients with advanced conges-tive heart failure. Classificatory analysis showed a tendency toward a longer survival time in patients with dipSBP

≤6mmHg and a longer survival time in patients with dipDBP

≤5mmHg and dipMBP ≤6mmHg. In Borne et al’s 24 study,

using ambulatory blood pressure monitoring in congestive heart failure patients, functional class III and IV, of a nonhy-pertensive cause, systolic pressure circadian amplitude va-riations were correlated with the degree of ventricular dys-function calibrated by cardiac index; however, their prog-nostic value was not evaluated. The analysis of ambulatory blood pressure monitoring of patients with congestive heart failure functional class IV of different etiologies in the present sample, revealed that patients with larger systolic blood pressure sleep decrements had shorter survival ti-mes. This finding is contrary to what has been previously described for hypertensive patients when those without ni-ght decrements had greater impairment of target organs. In congestive heart failure, Borne et al 24 found smaller blood

(7)

8 9 8 9 8 9 8 9 8 9

particularly, SBPs, which was more closely correlated with survival in these patients than indexes of direct myocardial measurements, such as left ventricular diastolic diameter and ejection fraction.

These data demonstrate that measurement of systolic blood pressure with 24-hour ambulatory blood pressure mo-nitoring in patients with advanced congestive heart failure may better represent the integration of the neurohormonal system, cardiac function, and peripheral vasculature than indexes that directly evaluate the myocardium, such as left ventricular ejection fraction and diastolic diameter. In ge-neral, we observed that lower systolic blood pressures and larger night decrements of blood pressure evaluated by

24-hour ambulatory blood pressure monitoring were predictors of higher mortality. Comparative analysis of survival plots suggests that parameters of systolic blood pressures and night decrements of systolic, diastolic, and average blood pressures obtained by ambulatory monitoring were pre-dictors of mortality, which did not happen with left ventricular ejection fraction and diastolic diameter in this group of patients. These data seem to confirm the hypothesis that dy-namic evaluation with ambulatory blood pressure monito-ring is superior to that carried out at rest and that it may be a method of great usefulness for the evaluation of patients with advanced congestive heart failure, especially for establishing priority for heart transplantation.

1. Mann DL, Young JB. Basic mechanisms in congestive heart failure: recognizing the role of proinflammatory cytokines. Chest 1994; 105: 897-904.

2. The Consensus Trial Study Group. Effects of enalapril on mortality in severe con-gestive heart failure: results of the Cooperative North Scandinavia Enalapril Sur-vival Study (CONSENSUS). N Engl J Med 1987; 316: 1429-35.

3. Keogh AM, Baron DW, Hickie JB. Prognostic guides in patients with idiopathic or ischemic dilated cardiomyopathy assessed for cardiac transplantation. Am J Cardiol 1990; 65: 903-8.

4. Komajda M, Jais JP, Reeve F, et al. Factors predicting mortality in idiopathic dila-ted cardiomyopathy. Eur Heart J 1990; 11: 824-31.

5. Kelly TL, Cremo R, Nielsen C, et al. Prediction of outcome in late-stage cardio-myopathy. Am Heart J 1990; 119: 1111-21.

6. Koide T, Akihito K, Yutaka T, et al. Variable prognosis in congestive cardiomyo-pathy: role of left ventricular function, alcoholism, and pulmonary thrombosis. Jap Heart J 1980; 21, 4: 451-63.

7. Stelken AM, Younis LT, Jennison SH, et al. Prognostic value of cardiopulmonar-texercise testing using achieved of predicted peak oxygen uptake for patients wi-th ischemic and dilated cardiomyopawi-thy. J Am Coll Cardiol 1996; 27: 345-52. 8. Sparrow J, Parameshwar J, Poole-Wilson PA. Assessment of functional capacity

in chronic heart failure: time limited exercise on self-powerer treadmil. Br Heart J 1994; 71: 391-4.

9. Williams MJ, Odabashian J, Lauer MS, et al. Prognostic value of dobutamine echocardiography in patients with left ventricular disfunction. J Am Coll Cardiol 1996; 27: 132-9.

10. Giles TD, Roffidal L, Quiroz A, et al. Circadian variation in blood pressure and heart rate in nonhypertensive congestive heart failure. J Cardiovasc Pharmacol 1996; 28: 733-40.

11. Rosner B. Fundamentals of Biostatistics. 2nd ed. Boston: PWS Publishers, 1988.

12. Baker BJ, Detsky AS, Wesson DE, et al. Predictive value of M-mode echocardio-graphy in patients with congestive heart failure. Am Heart J 1986; 111: 697-702. 13. Gavazzi A, De Maria R, Renosto G, et al. The spectrum of the left ventricular size in dilated cardiomyopathy: clinical correlates and prognostic implications. Am Heart J 1993; 125: 410-22.

14. Mady C, Cardoso RHA, Barretto ACP, et al. Survival and predictors of survival in patients with congestive heart failure due to Chagas cardiomiopathy. Circula-tion 1994; 90: 3098-102.

15. Ortiz J, et al. One-year mortality prognosis in heart failure: a neural network ap-proached based on echocardiographic data. J Am Coll Cardiol 1995; 26: 1586-93. 16. Ortiz J, Matsumoto AY, Ghefter CGM, et al. Prognosis in dilated myocardial di-sease: influence of diastolic dysfunction and anatomical changes. Echocardio-graphy 1993; 10: 247-53.

17. Ortiz J, Matsumoto AY, Silva CES. O ecocardiograma na avaliação prognóstica da insuficiência cardíaca. Arq Bras Cardiol 1988; 51: 89-91.

18. Pernenkil R, Vinson JM, Shah AS, et al. Course and prognosis in patients >70 yrs of age with congestive heart failure and normal versus abnormal left ventricular ejection fraction. Am J Cardiol 1997; 77: 216-9.

19. Marcus RH, Lang RM, Neumann A, et al. A physiological aproach to drug terapy in dilated cardiomyopathy. Echocardiography 1991; 8: 173-86.

20. Devereux RB, Pickering TG. Relationship between the level, pattern and varia-bility of ambulatory blood pressure and target organ damage in hypertension. J Hypertens 1991; 8: S34-8.

References

21. Rowlands DB, Ireland MA, Glover DR, et al. The relationship between ambula-tory blood pressure and echocardiographically assessed left ventricular hyper-trophy. Clin Sci 1981; 61: 101-3.

22. Giaconi S, Levanti C, Pommei, et al. Microalbuminuria and casual and ambulato-ry blood pressure monitoring in normotensives and in patients with borderline and mild essential hypertension. Am J Hypertens 1989; 2: 259-61. 23. Shimada K, Kawamato A, Matsubayashi K, et al. Silent cerebrovascular disease in

the elderly: correlation with ambulatory pressure. Hypertension 1990; 16: 692-9. 24. Borne P, van de Abramowicz M, Degre S, et al. Effects of chronic congestive heart failure on 24-hour blood pressure and heart rate patterns: a hemodynamic ap-proach. Am Heart J 1992; 123: 998-1004.

25. Canesin MF, Barretto ACP, Giorgi DM, et al. Ambulatory twenty-four-hours blood pressure variation is associate with cardiac function and quality of life in patients with severe congestive heart failure: follow-up of 12 months. Eur Heart J 1998; 19: 512. 26. Zanchetti A. The role of ambulatory blood pressure monitoring in clinical

prac-tice. Am J Hypertens 1997; 10: 1069-80.

27. Verdecchia P, Porcellati C, Schillaci G, et al. Ambulatory blood pressure: an in-dependent predictor of prognosis in essencial hypertension. Hypertension 1994; 24: 793-801.

28. Verdecchia P, Schillaci G, Porcellati C. Dippers x non-dippers. J Hypertens 1990; 9: S42-S4.

29. Bridgen W, Sharpey-Schafer EP. Postural changes in peripheral blood flow in ca-ses with left heart failure. Clin Sci 1950; 9: 93-100.

30. Zucker IH, Earle AM, Gilmore GP. The Mechanism of adaptation of left atrial stretch receptors in dogs with chronic congestive heart failure. J Clin Invest 1997; 60: 323-31. 31. Zucker IH, Earle AM, Gilmore GP. Changes in the sensitivity of left atrial

recep-tors following reversal of heart failure. Am J Physiol 1979; 237: H555-9. 32. Levine TB, Francis GS, Goldsmith SR, et al. Activity of the sympathetic nervous

system and renin-angiotensin system assessed by plasma hormone levels and their relationship to hemodynamic abnormalities in congestive heart failure. Am J Cardiol 1982; 49: 1659-66.

33. Imai Y, Aihara A, Ohkubo T, et al. Factors that affect blood pressure varibility. Am J Hyperten 1997; 10: 1281-9.

34. Parati G, Pomidossi G, Albini F, et al. Relationship of 24 hour blood pressure me-an me-and variability to severity of target-orgme-an damage in hypertension. J Hyper-tens 1987; 5: 93-8.

35. Schillaci G, Verdecchia P, Borgioni C, et al. Lack of association between blood pressure variability and left ventricular mass in essential hypertension. Am J Hy-perten 1988; 11: 515-22.

36. Caruana MP, Lahiri A, Cashman PMM, et al. Effects of chronic congestive heart failure secondary to coronary artery disease on the circadian rhythm of blood pressure and heart rate. Am J Cardiol 1988; 62: 755-9.

37. Franciosa JA, Wilen M, Ziesche S, et al. Survival in men with severe chronic left ventricular failure due to either coronary artery disease or idiopathic dilated car-diomyopathy. Am J Cardiol 1983; 51: 831-6.

38. Cleland JGF, Dargie HJ, Ford I. Mortality in heart failure: clinical variables of prognostic value. Br Heart J 1987; 58: 572-82.

Imagem

Table I - Correlation between 24-hour, waking and sleeping systolic blood pressure (SBP24, SBPw, SBPs) with left ventricular ejection fraction (LVEF) and diastolic diameter (LVDD) (Pearson’s
Fig. 3 - Survival curves of patients with mean waking systolic blood pressure (SBPw) &gt;105mmHg (n=23) and of patients with SBPw &lt;105mmHg (n=15).
Fig. 5 - Survival curves of patients with mean blood pressure night decrements (dipMBP) &lt;6mmHg (n=30) and of patients with dipMBP &gt;6mmHg (n=8).

Referências

Documentos relacionados

Parece-nos muito claro que a resposta a tal pergunta nos ajudará a formular possibilidades de alteração do quadro; sempre tendo em vista o que colocamos acima, ou seja, os limites

We also observed that the parameters evaluated (systolic, diastolic and mean blood pressures, and heart rate) in stage F4 (for 5 min after anesthesia), F5 (cavity preparation),

Figure 1 shows the correlation between the differences of values measured with the mercury device and the test device with the average values of systolic and diastolic blood

Estabeleci como objetivos gerais para o estágio profissionalizante: Cimentação dos conhecimentos teóricos apreendidos no decurso dos cinco anos anteriores e implementação

Baseline systolic, mean and dia- stolic blood pressures were similar in all three exercise trials, and systolic, mean, and diastolic blood pressure responses were simi- lar during

The correlation coeffi- cients between weight and systolic, mean arterial and diastolic blood pressures meas- ured by the oscillometric method were -0.01, 0.06 and 0.09,

Figure 1 - Mean ± SD values of heart rate (HR), mean, systolic and diastolic arterial blood pressures (MAP, SAP and DAP) recorded in six isoflurane-anesthetized

Clinical markers were assessed (body mass index, body fat percentage, waist circumference, acanthosis, systolic and diastolic blood pressures, laboratory parameters [glucose,