Laura Aelenei 21 de Junho de 2013

Design issues For

Net Zero Energy Buildings

Energy saving potential of a hybrid BIPV-T

system integrated with heat storage material

(2)

Laura Aelenei

1. Background

FRAME project Solar XXI building

2.Experimental analysis BIPV-T/PCM

Methodology and Results Conclusions

overview

Sustainable Energy Storage in Buildings Conference

(3)

Laura Aelenei

background - FRAME project

FRAME project

Sustainable Energy Storage in Buildings Conference

(4)

Laura Aelenei

FRAME project

Sustainable Energy Storage in Buildings Conference

FRAME

Prefabricated systems for low-energy buildings: design, modulation, prototyping and testing

Starting date: 15 of April 2012 Duration: 24 months

Objectives

o scientific investigation (numerical and experimental) of the heat and mass transfer phenomena through a building integrated façade module, deep thermal efficiency analysis of the main processes (convection, radiation, conduction) developing through the module expecting to bring out the geometrical, physical features and the ventilation strategies for which the system will be likely to exhibit a maximum thermal and energy efficiency;

o study of innovative system, a prefabricated façade system integrating photovoltaic modules (PV) and phase change materials (PCM), in order to broaden knowledge of potential uses of PCM in energy storage applications and to increase PV efficiency by providing an energy storage mechanism thereby improving supply and demand load matching.

o integrated in building façade contribute to sustainable and energy efficient rehabilitation of buildings and also to the achievements of EU 2020 targets (20% reduction of energy demand, 20% ratio of renewable energy sources of the final energy consumption, 20% reduction of CO2 emissions).

(5)

FRAME project

Sustainable Energy Storage in Buildings Conference

FRAME

Prefabricated systems for low-energy buildings: design, modulation, prototyping and testing

Starting date: 15 of April 2012 Duration: 24 months

Work plan

Task 1: Numerical evaluation and optimization (MATLAB/SIMULINK)

Scientific numerical investigation of the heat and mass transfer phenomena through the building integrated façade modules.

Task 2: Experimental evaluation: construction, integration on SOLARXXI building facade

Two prototypes will be constructed and extensively tested through 12 month period under real conditions. Temperature and heat flux sensors will be installed on each system layers and in the air gap.

Task 3: Building Energy Savings Assessment: Energy Plus simulation towards the evaluation of

the impact of the integration of the prefabricated module on the thermal comfort and on energy

demand, economic cost-effective analysis.

(6)

Laura Aelenei

FRAME project

Sustainable Energy Storage in Buildings Conference

FRAME

Prefabricated systems for low-energy buildings: design, modulation, prototyping and testing

Starting date: 15 of April 2012 Duration: 24 months

Stage of development (1/2 of the project)

 Numerical model developed and validated

 1st Prototype installed and tested for the Winter conditions (and Spring time);

 1st simulations for optimization started (changing the air gap width, PCM, operation mode, flow rate);

 Task 3 started – building energy savings assesment for a small scale space (one

room), validation of the numerical model with experimental results

(7)

Laura Aelenei

background - Solar XXI building

Solar XXI

Sustainable Energy Storage in Buildings Conference

(8)

Laura Aelenei

Solar XXI

Sustainable Energy Storage in Buildings Conference

General characteristics

Location Lisbon

Latitude 38°46'20.27" north Longitude 9°10'39.83" west

Owner National Energy and Geology Laboratory (LNEG)

Project co-ordinator Helder Gonçalves

[email protected]

Architect Pedro Cabrita, Isabel Diniz

Building costs (tax included) 800 €/m2

Typology Office building

Climate data Temperate

Heating period 5.3 month Heating Degree Days 1190ºC (Tb 20ºC)

Main stimulation of the project Test, experimental, research

Site context Urban

Building construction High

Number of occupants 20 pc

Number of stories 3 pc

Number of buildings 1pc

Heated net floor area 1200 m2

Gross floor area 1500 m2

Total envelope area 1436 m2

Envelope to volume ratio 0.4 m-1

SOLAR XXI

general informations

(9)

Laura Aelenei

Solar XXI

Sustainable Energy Storage in Buildings Conference

The main objective of the project Solar XXI building was to design a office building with low energy consumption, integrating renewable technologies (solar thermal and photovoltaic) and passive systems for heating and cooling.

The strategies and systems were planned and integrated from the beginning of its

design.

(10)

Laura Aelenei

Solar XXI

Sustainable Energy Storage in Buildings Conference

The building was constructed to maximize the use of renewable energy, integrating the following solutions and strategies:

Winter time

• Optimization of thermal envelope;

• Increase the area of solar heat gains – south solar façade, as a direct gain system for heating;

• BIPV-T, heat recovery by natural convection in the photovoltaic façade for indoor environmental heating;

• Solar collectors for heating purpose

(11)

Laura Aelenei

Solar XXI

Sustainable Energy Storage in Buildings Conference

The building was constructed to maximize the use of renewable energy, integrating the following solutions and strategies:

Summer time:

• External shading devices in the south oriented windows;

• Passive cooling system using buried pipes;

• Natural ventilation;

Natural lighting: large windows area, skylights

(12)

Laura Aelenei

Solar XXI

Sustainable Energy Storage in Buildings Conference

Renewable Energy Systems

-5000 -4000 -3000 -2000 -1000 0 1000 2000 3000 4000 5000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Energy (kWh)

PV supply car parking 2 PV supply car parking 1 PV supply building façade Electric consumption

RES Integration Area

(m

2

) Installed Peak power

(kW) Productivity (kWh/kW) 76 PV multicristalline silicon modules Building façade 96 12 1004

100 PV amorphous silicon Car parking 1 95 6 1401

150 PV CIS thin-film modules Car parking 2 110 12 1401

CPC Thermal Solar Collectors Building roof 16 11 MWh, from which 5MWh being used

(13)

Laura Aelenei

Experimental analysis BIPV-T/PCM

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

(14)

Laura Aelenei

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

DESCRIPTION OF THE SYSTEM

Material Density (Kg/m3

)

Specific heat (J/Kg K)

Thermal conductivity

(W/m K)

Specifications

PV 2330 677 148

PV and PCM absorptivity and

emissivity is 0.9 PCM gypsum

board

1000 1800 0.27 Latent heat of PCM

is 210 KJ/m2

PCM CHARACTERISTICS

Alba®balance plasterboard construction material contains specially

developed PCM microcapsules which change phase within comfort

zone (23°C or 26°C)

(15)

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

EXPERIMENTAL SET-UP

PCM surface facing room

PCM surface facing air gap

Air gap

between PCM and PV

PV facing air gap

PV outside PT100 2x2,3mm PT100 2x2,3mm PT100 2x2,3mm PT100 2x2,3mm PT100 2x2,3mm

T51 T41 T31 T21 T11

T52 T42 T32 T22 T12

T53 T43 T33 T24 T13

T54 T44 T34 T25 T14

Patch PT100 Patch PT100 Patch PT100 Patch PT100

S51 S41 S21 S11

Hukseflux HFP01-05

Hukseflux HFP01-05

Hukseflux HFP01-05

F5 F4 F2

(16)

Laura Aelenei

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

METHODOLOGY

20-02-2013 22-02-2013 24-02-2013 26-02-2013 28-02-2013

0 5 10 15 20 25 30

T inside T outside Irradiation

Time [DD-MM-YY]

TemperatureC]

0 200 400 600 800 1000

Irradiance [W/m 2]

(17)

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

METHODOLOGY

Case 1: 22th of February 2013

Cross section temperatures at different hours

Temperature and irradiation values

(18)

Laura Aelenei

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

METHODOLOGY

Case 2: 25th of February 2013

Cross section temperatures at different hours

Temperature and irradiation values

(19)

BIPV-T/PCM

Sustainable Energy Storage in Buildings Conference

CONCLUSIONS

 For both cases the thermal behavior of the BIPV/T-PCM system presents a

highest temperature difference at different hours and between the maximum and minimum values at the PV module and in the air gap and a more constant

temperature at PCM gypsum board and inside room.

 Even, on a day with low irradiation, cloudy, the PCM gypsum board layer presents temperatures of about 20ºC during daytime.

 The room temperature presents constant behavior with the values a of 20ºC

during daytime and between 16-18ºC during nightime.

(20)

OBRIGADO

Laura Aelenei

[email protected]

Thank you for your attention!

This work is part of a project FRAME-Prefabricated systems for low energy buildings: design, modulation, prototyping and testing, PTDC/AURAQI-AQI/117782/2010 co-financed by FEDER

Referências

Documentos relacionados

Figura 4- Média, erro padrão e desvio padrão de alturas m para as imputações em cada posição de retirada dos dados com 5% de ausência Na aplicação do Proc UNIVARIATE do SAS Anexo

Os principais itens analisados nos livros didáticos sobre os temas, “Vidros e Metais”, são: processos metalúrgicos para obtenção dos metais, os impactos sociais, as

Considerando o tema controverso, o presente artigo, sem a intenção de esgotar o assunto, apresenta os principais pontos do debate que envolve o fornecimento de

Ministry of Science, Education and Sport, and the Croatian Science Foundation; the Research Promotion Foundation, Cyprus; the Ministry of Education and Research, Recurrent

Este capítulo trata da problemática da formação de professores no Ensino Superior no contexto da EaD, face a necessidade de entender as concepções dessa modalidade de

Com efeito, não obstante a maior dependência europeia de petróleo russo em rela- ção ao que se regista no gás natural, o facto é que a conjugação da especificidade do mercado deste

Figure 1 depicts the energy performance results for total energy, heating energy, and cooling energy consumption for the fifty generated buildings according to the reference

PARÁGRAFO TERCEIRO: As empresas integrantes da categoria representada pelo Sindicato do Comércio Varejista de Santa Cruz do Sul, estão obrigadas a remeter ao Sindicato Patronal