COMPARATIVE EVALUATION FOR BARITE MORTAR ATTENUATION USING ISO RADIOPROTECTION QUALITIES

A. T. de Almeida Junior

Brazilian Institute for Safety and Health at Work - FUNDACENTRO, Minas Gerais, Brazil

M. S. Nogueira

Center of Development of Nuclear Technology - CDTN/CNEN, Minas Gerais, Brazil

M. A. P. Santos

Regional Center for Nuclear Science - CRCN/CNEN, Pernambuco, Brazil

M.P.A. Potiens, L. L. Campos

Institute of Energy and Nuclear Research - IPEN/CNEN, S˜ao Paulo, Brazil

The barite mortar, which is composed of cement, sand, water, barium sulphate, have been used widely in

radiology facilities as shielding material for radiation protection purposes, as they present some advantages

such as: high efficiency as attenuation materials, easy to handle application, easy availability in the domestic

market and low cost. However, in practice the dimensioning of the mortar and the barite concrete used in

plastering and construction of walls, respectively, is determined by the principle of equivalence of thickness in

relation to lead or concrete. This procedure results in a overestimated dimensioning, given the possibility of

occurrence of well significant errors, in function of the difference of specific density between lead or concrete

and the barite The main aim of this work is to characterize the barite mortars found in different regions of

Brazil by measuring photons transmission. Plates of different thickness were fabricated by the manufacturer

to test this research in the laboratory. The plates were irradiated with ISO X-ray beams (N60, N80, N110

and N150), generated by Pantak HF320 X-ray equipment, at the IPEN/CNEN laboratories and CRCN/CNEN,

using X-ray spectrometry as well as measures of ionization chamber. It was also determined the HVL and the

mean energy in this energy range. Results obtained in this work point out the importance of the knowledge

of the X-ray spectra for accurate determination of ambient dose equivalent and effective dose values. The

photons transmission is one of the used parameters for calculate the shielding material thickness. The authors

are thankful to FUNDACENTRO, CNPq and IPEN. This work was supported by FAPEMIG and Ministry of

Science and Technology - MCT/Brazil, through the Brazilian Institute of Science and Technology (INCT) for

Radiation Metrology in Medicine

Referências

Documentos relacionados

Essa anormalidade constitui uma das altera¸c˜oes mais freq¨ uentes do trato biliar e, por isso, a comunidade cient´ıfica tem feito grandes esfor¸cos para esclarecer essa

A aplica¸c˜ao da espectroscopia de emiss˜ao por plasma induzido `a laser de alt´ıssima potˆencia (Laser-Induced Breakdown Spectrometry - LIBS) ´e uma t´ecnica que permite

Sobre esse ´ ultimo, o fosfato de c´alcio, observa-se que ele aparece, na maioria dos casos, numa forma de caro¸co ou n´ ucleo de uma pedra que de oxalato de c´alcio, isto

The rubber samples were exposed to absorbed doses of irradiation range from 10 Gy up to 10 kGy using a 60 Co Gamma Cell-220 system (dose rate of 1.089 kGy/h).. Their responses

Characteristically, the laser interaction allows a layer by layer analysis and the third laser shot (used in this characterization) corresponds to a 120 µm depth (as determined by

At days 0, 4 and 8 post burn, normal skin/wound interface images were obtain using optical coherence tomography (OCT), as well as, skin samples was collected to histology analyses

Neste trabalho, a varia¸c˜ao de temperatura ´e calculada para um dente humano submetido a v´arios pulsos na linha de 510 nm do laser de Cu-HBr, que ´e uma linha fracamente absorvida

With time integrated emission technique , some lines were recorded in a integrated spectrum and it was possible to determine the electron excitation temperature using Boltzmann