• Nenhum resultado encontrado

An Automatic Near-field Characterization System with Multipolar Expansion Approach Rafael P B Muylaert

N/A
N/A
Protected

Academic year: 2021

Share "An Automatic Near-field Characterization System with Multipolar Expansion Approach Rafael P B Muylaert"

Copied!
1
0
0

Texto

(1)

An Automatic Near-field Characterization System with Multipolar Expansion Approach

Rafael P B Muylaert

1

, Carlos A. F. Sartori

1,2,3

, Francisco X. Sevegnani

1

, Aparecido S. Nicolett

1

, Laurent Krähenbühl

4

1

Pontifícia Universidade Católica – FCET/PUCSP- São Paulo/SP - Brazil E-mail: [email protected]

2

Instituto de Pesquisas Energéticas e Nucleares -IPEN/CNEN-SP - Brazil

3

Escola Politécnica da Universidade de São Paulo -LMAG/PEA/EPUSP

4

Université de Lyon, Ampère (CNRS UMR5005), ECL, France

The importance of the radiated equivalent sources characterization and Electromagnetic Compatibility studies has been emphasized in the present literature. It mentions the methodology based on the multipolar expansion in spherical harmonics of the near-field sources. Details of this methodology and of the prototypes suitable for determining components of the multipolar expansion are shown, for instance, in (Vincent, Benjamin, et al. "Loop antennas for near-field multipolar-expansion identification: first experimental validations." Instrumentation and Measurement, IEEE Transactions on 59.12 (2010): 3086-3092.), and T. Q. V. Hoang, A. Bréard, and C. Vollaire, “Near Magnetic Field Coupling Prediction Using Equivalent Spherical Harmonic Sources,” IEEE Trans. on EMC, Vol. 56, n°6, pp. 1457-1465, 2014.).

Nevertheless, these prototypes requires that either the device under test or the loop sensors be constantly positioned between all the measurements, to get the proper components necessary to represent accurately complex radiated sources, thus resulting in a time-demanding approach.

In order to minimize the aforementioned constraints, an automatic system is proposed, in which the positioning feedback is done by computer vision and the movement is provided by stepper motors, and nonmagnetic pulleys, carefully located and operated in order to not interfere in the field measurements. To improve the mechanical precision, the main mechanical components or parts of this system were carried out using CNC equipment.

The validation was based in previous results obtained by the authors.

Although, the spherical harmonics are used so far, the proposed system also allows implementing the equivalent cylindrical ones, being considered as part of future work. Thus, higher degrees of precision will be allowed, since higher order and degrees of the desired component of the multipolar expansion can be obtained by this system.

Figure 1 - Automatic antenna assembly (left) preliminary validation results (right) -60.0

-50.0 -40.0 -30.0 -20.0 -10.0 0.0

1 100 10000

Gain [dB]

f[KHz]

―experimental results

―analytical data

Referências

Documentos relacionados

A partir disso, conclui-se que a decisão que revoga a tutela antecipada em matéria de benefícios previdenciários não pode ter eficácia ex tunc, pena de se negar normatividade

Figure 34: Exemplos de mapas de PET 11C-pPIB de áreas de diminuição de captação de um único sujeito do grupo DA em relação aos sujeitos do grupo Controle Idosos Saudáveis N= 27

Euler (EULER, 1744,1772) também chegou aos dois novos exemplos encontrados por Wallenius em 1772, depois de ter publicado, em 1740, um trabalho sobre cálculo de áreas

Os dados do Quadro 34 mostram que o impacto em termos de transparência da informação contabilística provocado pela adoção das normas IFRS nos impostos diferidos das demonstrações

Gradualmente desinteressados de uma participação meramente ritual e ritualizada na eleição de um órgão que, embora vocacionado para representar a escola perante o Ministério da

In an active construction such as (1a) below, for example, its external argument is realized as the syntactic subject, bearing nominative Case and triggering

Dada a importância desse conhecimento, o presente trabalho propô-se identi- ficar a percepção dos formandos do Centro de Ciên- cias da Saúde (CCS) da Universidade Federal de

Lateral cephalometric X-rays were used to analyze the vertebral bone age of the individuals according to the method proposed by Caldas, used on both fe- male and male