Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
PUBLIC -5058-CO900H
T01 - Connected Enterprise – Integrando
Controle e Informação
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC 2
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
The Internet of Things
7.2
6.8
7.6
Rapid Adoption rate
of digital
infrastructure:
5X faster than
electricity and
telephony
50
Billion
“Smart Objects”
50
201
0
2015
2020
0
40
30
20
10
B
ill
ions
of
dev
ic
es
25
12.5
Inflection
point
Timeline
19
Billion
1.6
in Latam
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Manufatura
27%
Varejo
Serviços de Informação
Financeiros & Seguros
Outras Indústrias
11%
9%
9%
44%
$3.8 Trilhões
INDUSTRIAL
Internet Das Coisas
Estamos falando em $14T
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Things… Coisas…
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Visão de futuro
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Dispositivos Móveis vs Desktops
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Voz vs Texto
9
• 42% dos adolescentes
podem teclar de olhos
vendados
• Mensagem de texto é a 2a
coisa mais utilizada no
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Google e Facebook
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Hardware vs Software (App)
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC 12
IoT
INFORMATION
TECHNOLOGY
Connected Enterprise
é nossa visão de integração
IT/OT
OPERATIONS
TECHNOLOGY
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Solução, Colaboração e Convergência
The Connected Enterprise
CONECTANDO
Assessment
Secure &
Upgrade
Working
Data
Capital
Analytics
Collaboration
CONNECTED
ENTERPRISE
Maturity Model
5 STAGE
EXCELENCIA
OPERACIONAL
PESSOAS
PROCESSOS
TECNOLOGIA
+
+
Software
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
The Connected Enterprise
Integrated Control and Information
Enterprise Optimization
Information Aggregation
and Analytics
Converged Secure Network
Infrastructure
Multi-disciplined
Control
Intelligent Assets
Business
Management
Production
Management
Operations
Engineering
Maintenance
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Eficiência Operacional
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Informação em tempo real
Fieldbus
Internet
Automation
Network
Enterprise
Network
Device
Network
Discrete
Motion
Safety
Process
Power
Ethernet
Programmable
Controllers
Programmable
Automation
Controllers
Robots
Motion
Controllers
Servo
Drives
Encoders
I/O
Drives
Cameras
Voice
Asset
Management
HMI
Operator
Consoles
Historian
Energy
Management
Instruments
Valves
Safety
Controllers
Safety
I/O
Drives
w/ Safety
Light
Curtains
Drives
Starters
Overloads
Smart
Motor
Controllers
Process
Controllers
Barcode
Scanners
Secure
Remote
Access
EtherNet/IP
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Rockwell Automation Stratix
Switches Gerenciáveis com Tecnologia Cisco
O melhor da Cisco
Cisco IOS™
Conjunto de recursos e arquitetura Catalyst™
CLI (linhas de comando) e gerenciador de dispositivos
Integração segura com a rede corporativa
O melhor da Rockwell Automation
Common Industrial Protocol (CIP) interface com a arquitetura
integrada da Rockwell Automation™
RSLogix 5000™ para configuração via Add-on Profile (AOP)
Lógica pré-definida com tags lógicos para diagnósticos
FactoryTalk™ faceplates para visualização
O melhor para o chão de fábrica
Compact flash para substituição com“zero-configuração”
Níveis de proteção compatíveis com ambiente Industrial
Configurações de fábrica para Automação Industrial
Fácil manutenção
Um produto único no
mercado …
…Integrando os
ambientes corporativo e
de manufatura
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Conecte-se com seus dispositivos
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC 21
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Tendências de Segurança em Redes
Industriais
Padrões estabelecidos de Segurança Industrial
22
International Society of Automation
ISA-99
Industrial Automation and Control System (IACS) Security
Defesa-em-Camadas.
Implementação de DMZ.
National Institute of Standards and Technology.
NIST 800-82
Industrial Control System (ICS) Security
Defesa-em-Camadas
Implementação de DMZ .
Department of Homeland Security / Idaho National Lab.
DHS INL/EXT-06-11478
Control Systems Cyber Security: Defense-in-Depth Strategies
Defesa-em-Camadas
Implementação de DMZ
Uma aplicação segura depende de multiplas camadas de proteção.
Segurança Industrial deve ser implementada como um sistema.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Tendências de segurança Industrial
Modelo Lógico para Zonas Seguras
23
Level 5
Level 4
Level 3
Level 2
Level 1
Level 0
Remote Gateway Services Patch Management AV Server Application Mirror Web Services Operations Application Server Enterprise NetworkSite Business Planning and Logistics Network E-Mail, Intranet, etc.
FactoryTalk Application Server FactoryTalk Directory Engineering Workstation Remote Access Server FactoryTalk Client Operator Interface FactoryTalk Client Engineering Workstation Operator Interface Batch Control Discrete Control Drive Control Continuous Process Control Safety Control
Sensors Drives Actuators Robots
Enterprise
Security
Zone
Industrial
DMZ
Industrial
Security
Zone
Cell/Area
Zone
Web
CIP
Firewall Firewall Site Operations and Control Area Supervisory Control Basic Control ProcessLogical Model
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Rede Industrial Convergênte
Arquitetura de Rede
Célula de
Acesso
Nível 0-2
Rede de
Produção
Nível 3
Demilitarized
Zone
(DMZ)
Controle Real-Time
Convergência <100ms
Tráfego Multicast
Simplicidade
Integração MFG
Segmentação
Redes Multi-Serviço
Aplicações e Gerenciamento de
Segurança
Controle de Acesso
Proteção contra Ameaças
Rede Corporativa
Nível 4-5
Gbps Link for Failover Detection Firewall (Active) Firewall (Standby) FactoryTalk Application Servers Cisco ASA 5500 Cisco Catalyst Switch Network Services Cisco Catalyst 6500/4500 Cisco Cat. 3750 StackWise Switch Stack Patch Management Terminal Services Application Mirror AV Server Cell/Area #1 (Redundant Star Topology) DriveController
HMI Distributed I/O
Controller Drive Drive HMI Distributed I/O HMI Cell/Area #2
(Ring Topology) (Bus/Star Topology)Cell/Area #3
Rockwell Automation Stratix 8000 Layer 2 Access Switch
Controller
Integração de IT Corporativa
Colaboração
Wireless
Otimização de Aplicação
Web Apps DNS FTP InternetCopyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Segurança de Rede
•
Segurança Física
– limitar o acesso físico a
pessoas autorizadas: areas, paineis de controle,
dispositivos, cabeamentos e sala de controle –
acompanhamento e monitoração de visitantes
•
Segurança de Rede
– infra-estrutura – utilização
de firewalls com IDS/IPS e proteção da
integridade dos equipamentos de redes como
Switchs e Roteadores
•
Manuseio de Computadores
– gerenciamento de
patchs, utilizar software antivirus e remoção de
aplicativos, protocolos e serviços não utilizados
•
Segurança de Aplicação
– utilizar software de
controle de acesso, autenticação e auditoria
•
Manuseio de dispositivos
– utilizar
gerenciamento de mudanças e restringir o
acesso
Defense
in Depth
Computer
Device
Physical
Network
Application
Múltiplas camadas
de proteção
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
O que é o Industrial Data Center?
26
Solução completa Turn key:
Hardware
Software
Factory assembly
Configuração On-site
Documentação
Suporte TechConnect
SM
Líderes de mercado em colaboração com Rockwell Automation para ajudar seus
negócios a terem todos os benefícios de virtualização e conexão entre chão de fábrica
e o ambiente Corporativo.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
Um número único para suporte
27
Suporte disponível 24x7 ou monitoração remota
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved.
PUBLIC
PUBLIC -5058-CO900H
www.rockwellautomation.com