• Nenhum resultado encontrado

TECHNO 35. Code: SE. Thermostatic Fixed/Flexi Shower Kit. technical specifications. Pack consists of:

N/A
N/A
Protected

Academic year: 2021

Share "TECHNO 35. Code: SE. Thermostatic Fixed/Flexi Shower Kit. technical specifications. Pack consists of:"

Copied!
9
0
0

Texto

(1)

technical specifications

TECHNO 35

Thermostatic Fixed/Flexi Shower Kit

Code: 600302SE

www.cifial.co.uk

cifialuk@btconnect.com

dimensions mm

Pack consists of:

1 x 600V32SE Thermostatic Shower valve

made up of:

1 x 35830SE Trim Set

1 x 3580017 Valve Rough

1 x 070 Air Soft shower handset

1 x 048 Shower Hose

1 x 3450220 Technovation Wall Outlet

1 x 34501TH Technovation Slider Bar

1 x 142CP Air Fixed Head & Wall Arm

made up of:

1 x 202 Air Fixed Head

1 x 046 wall arm

(2)

Termostática embutida 3 furos - 2 saídas

Concealed Thermostatic 3 holes - 2 outlet

www.cifial.pt | cifial@cifial.pt www.cifial.es| cifial@cifial.es www.cifial.co.uk | sales@cifial.co.uk www.cifialusa.com

www.cifial.pl | cifial@cifial.pl

dimensões / dimensions mm

código / code: 35830SE-xxx

instruções de instalação

technical specifications

Style 35 / Technovation 35

56 65352 983S E04 7D0 1

(3)

Instalador: Por favor entregue todas as instruções que acompanham este produto ao seu proprietário. Installer: Please leave all leaflets with the building owner to file for future reference

Notas / Notes:

1) Na instalação, alinhar o ponto vermelho do anel limitador de temperatura com o número 38 impresso no espelho. The red dot on the temperature limit ring must be aligned with the number 38 on the back plate.

2) xxx indica o código do acabamento. xxx represent different finishes.

3) (**) conjunto pré-montado de fábric 3580017. (**) kit 3580017 pre-assembled at factory.

technical specifications

3580017

Válvula Termostática Embutida 2 Furos - 1 Vias Concealed Thermostatic Valve 2 Holes - 1 Outlet Vendido Separadamente / Sold Separately

Válvula ceramica Ceramic cartridge 5710283 (**) Copo de protecção Protection cap (**) Parafuso Screw (**) Cartucho termostático Thermostatic cartridge 5711607 (**) Protecção Protection (**) Válvula anti-retorno Check valve (**) Taco

End cap & isolating valve (x2) (**)

Parafuso Screw (x2) (**)

código / code: 35830SE-xxx

665352 983S E04 7D0 1 Corpo da válvula Valve body vendido separadamente sold separately 3580017

Anel cartucho termostático Thermostatic cartridge sleeve 3447012-xxx

Espelho Backplate 3447187-xxx

Conjunto corpo manipulo Handle body assembly 3491167-xxx Anel termostática

Trim ring 3442050-xxx

Anel limitador temperatura Temperature limit ring 3300658

(vêr nota / see note: 1) Anel cartucho termostático

Thermostatic cartridge ring 3442022-xxx Anel termostática Cartridge sleeve (x2) 3400301 Haste manipulo Lever handle (x2) 5713945 Perno Screw (x2) 50000M50250 Corpo manipulo Handle body (x2) 5713931 Parafuso Screw (x2) 5020137 Casquilho Sleeve (x2) 3400449

www.cifial.eu

(4)

instruções de instalação

technical specifications

código / code: 35830SE-xxx

56 65352 983S E04 7D0 1

PT

Operação

EN

Operation

www.cifial.pt | cifial@cifial.pt www.cifial.es|cifial@cifial.es www.cifial.co.uk | sales@cifial.co.uk www.cifialusa.com www.cifial.pl | cifial@cifial.pl 20 10 5 0 0,0 1,0 1,5 2,0 35 3,0 25 15 40 45 50 0,5 2,5 30 caudal flow (l/min)

pressão / pressure (bar) Pressão vs caudal / Pressure vs Water Flow

Mistura (banheira) Mix (bath tub) 100% água fria (banheira) 100% cold water (bath tub)

1. Remover o manípulo de regulação de temperatura.

2. Confirmar se o anel limitador de temperatura na haste da válvula termostática apresenta a marca vermelha coincidente com a marca 38ºC gravada no espelho; se não estiver corrigir a posição.

3. Abrir o manípulo de regulação de caudal, deixar a água correr, e verificar com a ajuda de um termómetro a temperatura da água. Aquando da calibração, é aconselhável a escolha de uma temperatura que ronde os 38ºC. Para o conseguir, rodar a haste da válvula termostática no sentido dos ponteiros do relógio para aumentar a temperatura ou vice versa. Para rodar a haste, pode utilizar o manípulo termostático carregando no botão, se necessário.

4. Estando a temperatura a 38ºC aplicar o manípulo no sistema alinhando o botão com a marcação 38ºC. 5. A válvula termostática fica assim calibrada, conforme os seus próprios requisitos de funcionamento. 6. Aperte o manípulo termostático com o parafuso respectivo.

nota: Recomendamos que regularmente se rode o manípulo de regulação de temperatura entre os limites máximo e mínimo, premindo o botão

de segurança e com a misturadora aberta. Desta forma evitam-se incrustações de calcário que podem bloquear o cartucho termostático.

Antes de usar - Regulação da temperatura

Prior to use - Setting the temperature

The upper handle turns on and off the water and controls the flow rate. The lower handle controls only the water temperature.

The confort zone is in the range from 32ºC to 38ºC, but total range is 28ºC to 48ºC. Protection against scalding stops the rotation of the handle at 38ºC. If water above 38ºC is desired, press on the button and turn the knob counterclockwise, to prevent scalding, ensure that the handle is left in a previous position (= or <38ºC).

1. With the stop valve (flow control) in the off position, remove the thermostatic valve handle and the temperature limit ring. 2. Put back on the thermostatic valve handle and turn clockwise until the cartridge “clicks”. This is now set at fully cold. 3. Turn on stop valve and turn the thermostatic valve handle anti-clockwise until the desired temperature is reached, ie 38ºC. Use a thermometer to check if the temperature is correct.

4. Turn off the stop valve, remove the thermostatic valve handle and replace the temperature limit ring with the red dot in the 12 o’clock position, ie corresponding with the 38ºC on the etched plate.

5. Replace the thermostatic valve handle with the temperature override button position just prior to the 38ºC. 6. Your thermostatic valve is now ready for use.

note: It’s recommended that you rotate the thermostatic control handle between the maximum and minimum limits, by pressing security button,

and with the water running. This way you prevent limestone incrustation, that could block up the thermostatic cartridge.

O manípulo superior abre, fecha e regula o caudal da água. O manípulo inferior controla a temperatura da água. A temperatura da água considerada confortável está entre os 32ºC e 38ºC, mas a possibilidade de regulação vai dos 28ºC até aos 48ºC.

O anel limitador de temperatura evita queimaduras acidentais não permitindo que o manípulo seja rodado para além dos 38ºC. No caso de se pretender ultrapassar aquela temperatura, deve premir-se o botão e rodar o manípulo no sentido contrário dos ponteiros do relógio. Para prevenir queimaduras, deve assegurar-se que o manípulo seja recolocado numa posição anterior ao batente de segurança (= ou <38ºC).

2.

Marca vermelha orientada para os 38ºC Red mark aligned to the mark 38ºC

4.

Botão limitador contra-queimaduras Anti-scalding button

(5)

technical specifications

AIR SOFT

Flexi Shower Handset

Code: 070

www.cifial.co.uk

(6)

technical specifications

TECHNOVATION

Wall Outlet

Code: 3450220

www.cifial.co.uk

cifialuk@btconnect.com

dimensions mm

(7)

INSTRUÇÕES DE INSTALAÇÃO

INSTALLATION INSTRUCTIONS

código/code |

34500TH-xxx

34501TH-xxx

34502TH-xxx

(UK)

Barra de chuveiro / Shower slider bar

Techno / Technovation

5663406 983TH019D02

CIFIAL USA

USA P +1800 5284904 F +1800 5281969 info@cifialusa.com www.cifialusa.com

CIFIAL Torneiras, S.A.

Portugal T +351 256 780 700 F +351 256 780 710 cifial@cifial.pt www.cifial.pt

CIFIALDECOR, S.A. Espanha T +34 916 110 261 F +34 916 103 694 cifialdecor@infonegocio.com CIFIAL UK, Ltd. UK P +44 1933 402 008 F +44 1933 402 063 sales@cifial.co.uk www.cifial.co.uk

TORNEIRAS/PLUMBING

INS

TAL

ADOR /

INST

ALLER

:

P

or f

av

or entr

egue t

odas as ins

tr

uções q

ue acom

panham es

te pr

odut

o ao seu pr

opr

ie

tár

io.

Please lea

ve all leaf

le

ts wit

h t

he building o

wner t

o f

ile f

or futur

e r

ef

er

ence.

Código/Code Descrição/Description A

34501TH xxx Barra chuveiro 600 / Shower slider bar 600 583 34500TH-xxx

34502TH-xxx

Barra chuveiro 900 / Shower slider bar 900 Barra chuveiro 600 / Shower slider bar 600

883 583

A

(8)

7

6 PostePost 2

5 ParafusoScrew 4

4 Wall bracketFixador 2

3 Corpo central barra de chuveiroAdjustable handset holder 1 2 4 Bucha Raw plug 1 1 Casquilho Sleeve Descrição/Description Q 5663406 983TH019D02

8 Slider barTubo 1

2 Perno

(9)

technical specifications

AIR 180mm

Fixed Head & 300mm wall arm

Code: 142CP

www.cifial.co.uk

Referências

Documentos relacionados

The dairy production potential for grazing livestock was estimated with basis on the NLE data of the bromatological analysis of grasses, which was based on the RGB image

i) A condutividade da matriz vítrea diminui com o aumento do tempo de tratamento térmico (Fig.. 241 pequena quantidade de cristais existentes na amostra já provoca um efeito

Despercebido: não visto, não notado, não observado, ignorado.. Não me passou despercebido

In ragione di queste evidenze, il BIM - come richiesto dalla disciplina comunitaria - consente di rispondere in maniera assolutamente adeguata alla necessità di innovazione dell’intera

In the hinterland (Lika region) they are partly permeable but on higher positions at Velebit Mt. calcareous breccias are highly permeable. The best prove for the mentioned is

The limestone caves in South Korea include a variety of speleothems such as soda straw, stalactite, stalagmite, column, curtain (and bacon sheet), cave coral,

Karstic land use in the intertropical region, with fanning and cattle breeding dominant (e.g. the valley of São Francisco &gt; should be periodically monitored so that

Ousasse apontar algumas hipóteses para a solução desse problema público a partir do exposto dos autores usados como base para fundamentação teórica, da análise dos dados

The results showed that the higher effi ciency in light energy uptake, paired with better photochemical performance and better CO 2 fi xation in plants under direct sunlight