1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 12°C / 7°C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35°C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MAC020C MAC025C
Btu/h 18000 23500
W 5275 6887
W 2669 2730
A 12.6 12.6
V/Ph/Hz
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb 116 / 256 123 / 271
dBA 57 57
l/s / m3/hr 0.25 / 0.9 0.33 / 1.2
1 1
MAX. WATER OPER. PRESSURE kPa / psi
l/s / m3/hr 0.25 / 0.9 0.33 / 1.2 INSTALLATION PIPE CONNECITON mm/in
m 9.2 9.5
L / ft3
ROTARY SCROLL
0 - 100% 0 - 100%
kg/lb 1.1 / 2.4 1.8 / 4.0
NOMINAL WATER FLOW
PROPELLER / DIRECT
HIGH HEAD CIRCULATOR 220-240 / 1 / 50
800 / 31.5 1160 / 45.7
460 / 18.1 958 / 37.7 1309 / 51.5
574 / 22.6 MODEL
TYPE/DRIVE QUANTITY
NOMINAL COOLING CAPACITY
REFRIGERANT TYPE
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
SOUND PRESSURE LEVEL EVAPORATOR
CONDENSER FAN POWER SOURCE
CONTROL
STAGE OF CAPACITY CONTROL (Btu/h) COMPRESSOR
MATERIAL TANK
TYPE
CAPACITY/VOLUME
MILD STEEL COATED WITH ZING 22 / 0.78
REFRIGERANT CHARGING MASS
R22
1000 / 145
25.4 / 1 CAPILLARY TUBE
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
HYDRAULIC KIT
PUMP
WATER FLOW RATE PIPING
HEAD TYPE
General Data - R22 Cooling only
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 12°C / 7°C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35°C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MAC030C MAC040C
Btu/h 27500 40000
W 8059 11723
W 3491 4470
A 16.6 8.8
V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50
HEIGHT mm/in 800 / 31.5 1410 / 55.5
WIDTH mm/in 1160 / 45.7 1160 / 45.7
DEPTH mm/in 460 / 18.1 460 / 18.1
HEIGHT mm/in 958 / 37.7 1578 / 62.1
WIDTH mm/in 1309 / 51.5 1309 / 51.5
DEPTH mm/in 574 / 22.6 574 / 22.6
kg/lb 128 / 282 195 / 430
dBA 58 60
l/s / m3/hr 0.39 / 1.4 0.56 / 2.0
1 2
HIGH HEAD CIRCULATOR HORIZONTAL MULTISTAGE END-SUCTION MAX. WATER OPER. PRESSURE kPa / psi
l/s / m3/hr 0.39 / 1.4 0.56 / 2.0 INSTALLATION PIPE CONNECITON mm/in
m 9.6 9.7
L / ft3 22 / 0.78 40 / 1.41
SCROLL SCROLL
0 - 100% 0 - 100%
kg/lb 1.6 / 3.5 2.7 / 6.0
HYDRAULIC KIT
PUMP
WATER FLOW RATE PIPING
HEAD TYPE
NOMINAL WATER FLOW
REFRIGERANT CHARGING MASS
R22
1000 / 145
25.4 / 1 CAPILLARY TUBE
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
CONDENSER FAN POWER SOURCE
CONTROL
STAGE OF CAPACITY CONTROL (Btu/h) COMPRESSOR
MATERIAL TANK
TYPE
CAPACITY/VOLUME
MILD STEEL COATED WITH ZING PROPELLER / DIRECT MODEL
TYPE/DRIVE QUANTITY
NOMINAL COOLING CAPACITY
REFRIGERANT TYPE
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
SOUND PRESSURE LEVEL EVAPORATOR
General Data - R22 Cooling only
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 12°C / 7°C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35°C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MAC050C MAC060C
Btu/h 50000 53000
W 14654 15533
W 5245 6361
A 9.3 12.3
V/Ph/Hz
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb 196 / 432 203 / 448
dBA 60 61
l/s / m3/hr 0.70 / 2.5 0.74 / 2.7
2 2
MAX. WATER OPER. PRESSURE kPa / psi
l/s / m3/hr 0.70 / 2.5 0.74 / 2.7 INSTALLATION PIPE CONNECITON mm/in
m 7.5 8.3
L / ft3
SCROLL SCROLL
0 - 100% 0 - 100%
kg/lb 3.1 / 6.8 3.1 / 6.8
MODEL
TYPE/DRIVE QUANTITY
NOMINAL COOLING CAPACITY
REFRIGERANT TYPE
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
SOUND PRESSURE LEVEL
574 / 22.6
PROPELLER / DIRECT 380-415 / 3 / 50
HORIZONTAL MULTISTAGE END-SUCTION EVAPORATOR
PUMP
WATER FLOW RATE
40 / 1.41 CONDENSER FAN
POWER SOURCE
CONTROL
NOMINAL WATER FLOW
1410 / 55.5 1160 / 45.7 460 / 18.1 1578 / 62.1 1309 / 51.5
CHARGING MASS
R22
1000 / 145
25.4 / 1 CAPILLARY TUBE
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
HYDRAULIC KIT
STAGE OF CAPACITY CONTROL (Btu/h) PIPING
HEAD TYPE
REFRIGERANT COMPRESSOR
MATERIAL TANK
TYPE
CAPACITY/VOLUME
MILD STEEL COATED WITH ZINC
General Data - R22 Cooling only
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 12°C / 7°C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35°C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MAC080C MAC100C
Btu/h 78000 93000
W 22860 27257
W 8667 10175
A 16.3 17.0
V/Ph/Hz
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb 340 / 750 350 / 772
dBA 65 66
l/s / m3/hr 1.08 / 3.9 1.31 / 4.7
2 2
MAX. WATER OPER. PRESSURE kPa / psi
l/s / m3/hr 1.08 / 3.9 1.31 / 4.7 INSTALLATION PIPE CONNECITON mm/in
m 21.6 18.7
L / ft3
SCROLL SCROLL
0 - 50 - 100% 0 - 50 - 100%
kg/lb 4.5 x2 / 9.9 x2 3.9 x2 / 8.6 x2 PIPING
HEAD TYPE
REFRIGERANT COMPRESSOR
MATERIAL TANK
TYPE
CAPACITY/VOLUME
NA
CHARGING MASS
R22
1000 / 145
42 / 1 1/4"
TXV
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
HYDRAULIC KIT
STAGE OF CAPACITY CONTROL (Btu/h)
NA CONDENSER FAN
POWER SOURCE
CONTROL
NOMINAL WATER FLOW
1245 / 49.0 1500 / 59.1 900 / 35.4 1452 / 57.2 1732 / 68.2 1032 / 40.6
PROPELLER / DIRECT 380-415 / 3 / 50
HORIZONTAL MULTISTAGE END-SUCTION EVAPORATOR
PUMP
WATER FLOW RATE MODEL
TYPE/DRIVE QUANTITY
NOMINAL COOLING CAPACITY
REFRIGERANT TYPE
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
SOUND PRESSURE LEVEL
General Data - R22 Cooling only
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 12°C / 7°C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35°C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MAC120C MAC150C
Btu/h 116000 138000
W 33998 40445
W 11005 13779
A 22.9 26.7
V/Ph/Hz
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb 460 / 1014 540 / 1190
dBA 67 69
l/s / m3/hr 1.67 / 6.0 2.00 / 7.2
2 2
MAX. WATER OPER. PRESSURE kPa / psi
l/s / m3/hr 1.67 / 6.0 2.00 / 7.2 INSTALLATION PIPE CONNECITON mm/in
m 19.2 16.5
L / ft3
SCROLL SCROLL
0 - 50 - 100% 0 - 50 - 100%
kg/lb 6.0 x2 / 13.2 x2 7.1 x2 / 15.7 x2 MODEL
TYPE/DRIVE QUANTITY
NOMINAL COOLING CAPACITY
REFRIGERANT TYPE
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
SOUND PRESSURE LEVEL
1282 / 50.5
PROPELLER / DIRECT 380-415 / 3 / 50
HORIZONTAL MULTISTAGE END-SUCTION EVAPORATOR
PUMP
WATER FLOW RATE
NA CONDENSER FAN
POWER SOURCE
CONTROL
NOMINAL WATER FLOW
1245 / 49.0 1800 / 70.9 1150 / 45.3 1452 / 57.2 2032 / 80.0
CHARGING MASS
R22
1000 / 145
42 / 1 1/4"
TXV
UNIT DIMENSION
PACKING DIMENSION
UNIT WEIGHT
HYDRAULIC KIT
STAGE OF CAPACITY CONTROL (Btu/h) PIPING
HEAD TYPE
REFRIGERANT COMPRESSOR
MATERIAL TANK
TYPE
CAPACITY/VOLUME
NA