Handle for moving Handle for
moving
18
69
10
600 300
287.5 800
Terminal connections Left Power supply wiring Right Indoor/Outdoor wiring
Service panel Earth terminal
Service panel for charge plug Connection for
liquid pipe FLARE :6.35(1/4F)
Connection for
gas pipe FLARE :12.7(1/2F) Service port
183
440
23
90155
35° 43°
6-:33 drain hole 2-:12 drain hole
7045 400 500
347.4
226
0
43.6 155152 74.3 0
60 118
0
284.3
Less than
<Foundation bolt height>
18mm
100mm or more 500mm or more
2 sides should be open in the right,left and rear side.
*1*2 *1
350mm or more 100mm or more
Basically open
Air discharge
4-10×21 oval hole
Side air intake
Rear air intake
32.540
330300 365
150 500
Installation bolt pitch
FOUNDATION
Unit : mm
Outdoor unit
Outlines and dimensions
2 Outdoor unit
PUHZ-SW75VHA(-BS) Unit : mm
Air Intake
Rear Air Intake Handle for moving Handle for moving
322950
473 943
23
*1 447
*1 431 673
21
Handle for moving Handle for movingService panel
Earth terminal
Left···Power supply wiring Right···Indoor/Outdoor wiring
Terminal Connections Rear piping coverFront piping cover
Side Air Intake Handle for moving
40 54
28 370
19
417
53
5741
600175175
330
Rear Air Intake Air Discharge
Side Air Intake
Installation Feet2-U Shaped notched holes (Foundation Bolt M10) 2-12% 36 oval holes (Foundation Bolt M10)
30
22014514514530
81 219
71
71 Bottom piping hole (Knockout)
Drain hole (5-:33)
Piping Knockout Hole Details
195523 2792
92
4075
73
Right piping hole (Knockout) 63
Right trunking hole (Knockout)
Power supply wiring hole (2-:27Knockout)
:92
27 55
73 23
63
40 92 65
45
Front piping hole (Knockout) Front trunking hole (Knockout)
Power supply wiring hole (2-:27Knockout) 92:
4045 6592
27 55
23 7363
Rear piping hole (Knockout) Rear trunking hole (Knockout)
Power supply wiring hole (2-:27Knockout)
:92
Example of Notes
Refrigerant GAS pipe connection (FLARE):15.88(5/8 inch) Refrigerant LIQUID pipe connection (FLARE):9.52(3/8 inch) *1...Indication of STOP VALVE connection location.Over
Over Less than Piping and wiring connections can be made from 4 directions: front, right, rear and below
.
4 PIPING-WIRING DIRECTIONS 3 FOUNDA TION BOL TS 2 SER VICE SP ACE 1 FREE SP ACE (Around the unit)
The diagram below shows a basic example. Explanation of particular details is given in the installation manuals etc.
Over10 500
500 Over100
Dimensions of space needed for service access are shown in the below diagram.
Service space
Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally 30
.) <Foundation bolt height> FOUNDATION over 100mmover 500mm
over 10mm
FREE
over 10mm
Outdoor unit
Outlines and dimensions
2 Outdoor unit
PUHZ-SW100/120VHA(-BS) PUHZ-SW100/120YHA(-BS)
Handle for moving
Side Air Intake Front piping cover Rear piping cover
Air intake
Rear Air Intake Handle for moving Handle for moving
Terminal connection Left···Power supply wiring Right···Indoor/Outdoor wiring
Earth terminal Service panel Handle for moving 1 2
Air Discharge
Rear Air Intake Side Air Intake ····Refrigerant GAS pipe connction (FLARE)W15.88(5/8 inch) ····Refrigerant LIQUID pipe connection (FLARE)W 9.52(3/8 inch) *1 ···Indication of STOP VALVE connection location.
Example of Notes Piping Knockout Hole Details
600175175
330 417
4266
53 56 45
(19) 370 28
2-U Shaped notched holes (Foundation Bolt M10) 2-12 x 36 Oval holes (Foundation Bolt M10)
Installation Feet
30
4540 6592
27 55
23 7363
Rear piping hole (Knockout) Rear trunking hole (Knockout)
Power supply wiring hole (2-W27Knockout)
W92
1955 92
7540
73 63
2327
Right piping hole (Knockout) 92
Right trunking hole (Knockout)
Power supply wiring hole (2-W27Knockout)
W92
92 65
4540
27 55
23 7363
Front piping hole (Knockout) Front trunking hole (Knockout)
Power supply wiring hole (2-W27Knockout) 92W
14514522030145
81 219 71
71
Bottom piping hole (Knockout)
Drain hole (5-W33)
1350
23
950
A
*1 447
*1 431
371 635
322Handle for moving VHA YHA1,079A 930
Over
Over Over
Over
Less than Piping and wiring connections can be made from 4 directions: front, right, rear and below
.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit)
Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally .) <Foundation bolt height>
Dimensions of space needed for service access are shown in the below diagram.
The diagram below shows a basic example. Explantion of particular details is given in the installation manuals etc.
30
FOUNDATION10 500
150 500
Service space
FREE
Over 10mm
Over 10mm Over 150mm
Over 1000mm
Unit : mm
Outdoor unit
Outlines and dimensions
2 Outdoor unit
PUHZ-RP200/250YKA
FOUNDATION
30
Service space
150 500
500
10
The diagram below shows a basic example. Explanation of particular details are given in the installation manuals etc.
Dimensions of space needed for service access are shown in the below diagram.
<Foundation bolt height>
Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally
.)
1 FREE SPACE (Around the unit)2 SERVICE SPACE3 FOUNDATION BOLTS4 PIPING-WIRING DIRECTIONS Piping and wiring connections can be made from 4 directions: FRONT
,Right,Rear and Below.
Less than
Over Over
Over
Over Over 10mmOver 10mm
FREE Over 150mmOver 1000mm
PUHZ-RP200YKA PUHZ-RP250YKA
Model 424450Aconnection
ø9.52(3/8F) ø12.7(1/2F)
···Refrigerant GAS pipe connection (attached JOINT)ø25.4(Brazing locally) ···Refrigerant LIQUID pipe connection (FLARE) *1···Indication of ST OP VALVE connection location. *2···(FLARE)ø 19.05(3/4F)
1 2
2
Example of Notes Piping Knockout Hole Details
Power supply wiring hole (ø27Knockout)
Front piping hole (Knockout) Front trunking hole (Knockout)
Power supply wiring hole (ø40Knockout)
6055
63 73
55 27 26
7592
60 ø92
Power supply wiring hole (ø27Knockout) Right piping hole (Knockout) Right trunking hole (Knockout) Power supply wiring hole (ø40Knockout)
7550
26
63 27 5573 2992
92
60 ø92
Power supply wiring hole (ø27Knockout)
Rear piping hole (Knockout) Rear trunking hole (Knockout)
Power supply wiring hole (ø40Knockout)
75
6055
63 73 26
55 27
60
92
ø92
Drain hole (5-ø33) Bottom piping hole (Knockout)
81 45154 136
110160160160
86
1050Rear Air Intake Air Discharge
Side Air Intake
Installation Feet
2-U Shaped notched holes (Foundation Bolt M10)
2-12×36 Oval holes (Foundation Bolt M10) 370 28
60
30
225225
330
600
19 417
7042
40 53
56 0
Handle for moving
Rear Air Intake Side Air Intake
Handle for moving
632 369 26
1338
Handle for moving Handle for moving
Earth terminal362 Brazing
Service panel
Terminal connection Left···Power supply wiring Right···Indoor/Outdoor wiring
*1,*2 : 442 982 986
*1 A 342
Air intake 2
1 Front piping cover Rear piping cover
Unit : mm
Outdoor unit
Outlines and dimensions
2 Outdoor unit
PUHZ-FRP71VHA
Dimensions of space needed for service access are shown in the below diagram.
Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally
.)
Piping and wiring connections can be made from 4 directions: Front, right, rear and below
.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit)
The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc.
Rear piping hole (Knockout) Rear trunking hole (Knockout)
73 23
55 27
92 65
92 :
Power supply wiring hole (2-:27Knockout)
Front trunking hole (Knockout) Front piping hole (Knockout)
45 6592
40
63 73 23
55 27
92: Right piping hole (Knockout)
Right trunking hole (Knockout)
Power supply wiring hole (2-:27Knockout) 1955
23 2792
92
4075
73 63
:92
Piping Knockout Hole Details
3 4
2
1...Refrigerant GAS pipe connection (FLARE) :15.88 (5/8F) *Connect to indoor unit. ...Refrigerant LIQUID pipe connection (FLARE) :9.52 (3/8F) *Connect to indoor unit. ...Refrigerant GAS pipe connection (FLARE) :15.88 (5/8F) *Connect to cylinder unit or hydrobox. ...Refrigerant LIQUID pipe connection (FLARE) :9.52 (3/8F) *Connect to cylinder unit or hydrobox.
Example of Notes
This tap mark indicates the cylinder/hydro unit connection side for the following parts. ・Terminal bed for the connecting cables, S1/S2/S3. ・Stop valves, gas and liquid for the refrigerant connection.BK79F295H01
Air Discharge
Side Air Intake
Rear Air Intake
2-12×36 oval holes (Foundation Bolt M10) 2-U Shaped notched holes (Foundfation Bolt M10)
Installation Feet
417
61 54
53
19 370 28
41424242
175175600
330 30
43
Cylinder/Hydrobox wiringTerminal Connections 1 2Handle for movingService panel
Terminal Connections Left・・・Power supply wiring Right・・Indoor/Outdoor wiring Earth terminal
Handle for moving
950 322
943 473
23 673
429 375 696
Rear piping coverFront piping cover
Over 500mmOver 100mm
FREE
Over 10mmOver 10mm Drain hole (5-:33)1451451452203081219
Handle for moving
Rear Air Intake
Handle for moving
Air Intake
Side Air Intake
Handle for moving
Over
Over Over
Over
Less than
<Foundation bolt height> 30
FOUNDATION10 500
100 500
Service space