DATABOOK users are recommended to carefully read and use all contents inside for planning the CITY MULTI air conditioner and/or for preparing documentation for promotions. Microsoft ® , Windows ® , Windows Vista ® and Internet Explorer ® are registered trademarks of Microsoft Corporation US in the United States and other countries. In this manual, Windows ® 8.1 Pro is referred to as Windows 8.1, Windows ® 7 Professional is referred to as Windows 7, Windows Vista ® Business as Windows Vista, Windows ® XP Professional as Windows XP, and Windows ® 2000 Professional as Windows 2000.

Details of foundation work, channel work, insulation work, electrical wiring, power source switch and other items will be referred to the Installation Manual. Details of foundation work, channel work, insulation work, electrical wiring, power source switch and other items will be referred to the Installation Manual.

PEFY

Option: We recommend a synthetic fiber non-woven fabric filter (long-life filter) and a filter box. Option: We recommend a synthetic fiber non-woven fabric filter (long-life filter) and a filter box. Note * Details of foundation parts, duct parts, insulation parts, electrical wiring, power source switch and other items are in the installation manual.

Due to continuous improvement, the above specifications are subject to change without notice. kg/0.4536 2.The values ​​are measured at the factory setting of external static pressure. Keep the inlet space between the ceiling and the unit in case of bottom intake.

PEFY-P20,25,32VMR-E-L/R

A clearance of 50 mm or less between the top of the indoor unit and the end of the hanging bolt makes maintenance of the indoor heat exchanger easier. Air filter Hole for hanging bolt 4-14X30 Slot T erminal bed (power source) Solder joint refrigerant pipe (gas) 1 Drain pipe (outer diameter ø 32) (spontaneous drain) T erminal bed (transmission). 4.In case the inlet duct is used, remove the air filter (supplied with the unit) and then install the filter (field supply) on the suction side.

If you are using a field-supplied air filter, attach it in a location where the filter can be easily serviced. If you are using a field-supplied air filter, attach it in a location where the filter can be easily serviced.

PEFY-P200, 250VMH-E

Lifting bolt Refrigerant pipe solder joint (gas A copper tube) ···· Refrigerant pipe solder joint (liquid B copper tube) ···· Discharge hose I.D. Keep the service space for maintenance from below when cleaning the heat exchanger. 2. Keep the service space for maintenance from below when cleaning the heat exchanger.

3. Keep the service space at the bottom clear for maintenance when the fan motor is replaced.

PEFY-P200,P250VMHS-E

Center of gravity

Center of gravity A

PEFY-P20, 25, 32VMR-E-L/R

PEFY-P63VMS1(L)-EPEFY-P50VMS1(L)-E

Center of gravity Y

Obey local remote control (allowed) Local remote control display and operation Status OFF ON. TO OUTDOOR UNIT BC CONTROLLER WITH TECONTROL PE At the factory shipment, the motor connector is connected for power 220-230 V. TION NAME NAME SW5(A.B) Switch (for mode selection) Thermistor (pipe detection temperature /liquid) Thermistor (pipe temperature. detection/gas) 1.5 F Switch (for mode selection) Switch (for capacity code) Switch (address of 10th digit set) Switch (connection no.set) Switch (for mode selection) Switch (for model selection) Switch (for voltage selection).

LEV Float switch connector (Remote indicator) Connector (Central control) Connector (Remote switch) Thermistor (air inlet temperature. detection). ONOFF switch (for model selection) Switch (for static pressure selection) Switch (for static pressure selection) Connector (emergency operation) Thermistor (pipe temperature.detection/liquid) Thermistor (pipe temperature.detection/gas) .

TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER

TION NAME Connector (HA-A Terminal) SYMBOL NAME NOTE: 1. Connections to TB2,TB5,TB15 shown in dotted line are field work. NOTE: 1. The broken line part shows the circuit for the optional parts. 2.*A in the diagram is the connector for the discharge pump test operation. The drain pump runs continuously if the connector is inserted and power is supplied.).

PEFY-P200,250VMH-E

Switch (for selecting mode) Switch (for capacity code) Switch (for selecting mode) Switch (for selecting model) Switch (for selecting mode) Switch (assigning addresses of digits 1) Switch (assigning addresses of 10th digits) Switch (BRANCH No.) Switch (for static pressure selection) Switch (for static pressure selection) TB2 TB5 TB15. Internal controller board Noise filter board Inverter board Power supply board Power source terminal block Transmission terminal block Transmission terminal block Float switch Thermistor(pipe temperature.detection/fluid) Thermistor(pipe temperature .detection/gas) Thermistor(heat)Thermistor(inlet air temp.detection ) MFFan Motor AC Reactor (Power Factor Improvement) LED Diode Resistor Bridge (Power Supply) Current Sensor (AC) LED (Remote control supply).

5-1. Sound levels

5-2. NC curves

PEFY-P20,25VMR-E-L/R External static pressure : 5Pa

PEFY-P32VMR-E-L/R External static pressure : 5Pa

PEFY-P15VMS1(L)-E External static pressure : 5Pa

PEFY-P15VMS1(L)-E External static pressure : 15Pa

PEFY-P15VMS1(L)-E External static pressure : 35Pa

PEFY-P15VMS1(L)-E External static pressure : 50Pa

PEFY-P20VMS1(L)-E External static pressure : 5Pa

PEFY-P20VMS1(L)-E External static pressure : 15Pa

PEFY-P20VMS1(L)-E External static pressure : 35Pa

PEFY-P20VMS1(L)-E External static pressure : 50Pa

PEFY-P25VMS1(L)-E External static pressure : 5Pa

PEFY-P25VMS1(L)-E External static pressure : 15Pa

PEFY-P25VMS1(L)-E External static pressure : 35Pa

PEFY-P25VMS1(L)-E External static pressure : 50Pa

PEFY-P32VMS1(L)-E External static pressure : 5Pa

PEFY-P32VMS1(L)-E External static pressure : 15Pa

PEFY-P32VMS1(L)-E External static pressure : 35Pa

PEFY-P32VMS1(L)-E External static pressure : 50Pa

PEFY-P40VMS1(L)-E External static pressure : 5Pa

PEFY-P40VMS1(L)-E External static pressure : 15Pa

PEFY-P40VMS1(L)-E External static pressure : 35Pa

PEFY-P40VMS1(L)-E External static pressure : 50Pa

PEFY-P50VMS1(L)-E External static pressure : 5Pa

PEFY-P50VMS1(L)-E External static pressure : 15Pa

PEFY-P50VMS1(L)-E External static pressure : 35Pa

PEFY-P50VMS1(L)-E External static pressure : 50Pa

PEFY-P63VMS1(L)-E External static pressure : 5Pa

PEFY-P63VMS1(L)-E External static pressure : 15Pa

PEFY-P63VMS1(L)-E External static pressure : 35Pa

PEFY-P63VMS1(L)-E External static pressure : 50Pa

PEFY-P40,50VMH-E External static pressure : 50Pa

PEFY-P40,50VMH-E

PEFY-P63VMH-E

PEFY-P71VMH-E

PEFY-P80VMH-E

PEFY-P100,125,140VMH-E External static pressure : 50Pa

PEFY-P100,125,140VMH-E External static pressure : 100Pa

PEFY-P100,125,140VMH-E External static pressure : 200Pa

PEFY-P250VMH-E

PEFY-P100,125,140VMH-E External static pressure : 150Pa

PEFY-P200VMH-E

PEFY-P200VMHS-E External Static Pressure: 50Pa

PEFY-P200VMHS-E

PEFY-P250VMHS-E External Static Pressure: 50Pa

PEFY-P250VMHS-E

PEFY-P100,125VMH-E

PEFY-P140VMH-E

7-1. Optional parts line up for the Indoor unit

PEFY-P-VMS1 (L) -E

PEFY-P-VMH (S) -E

The actual dust situation affects the life of the filter, which should be taken into account at the application site.

7-3. Drain pump

7-4. Control box replace kit

PLATE A Q'ty

PLATE B 1

PLATE C 1

COVER A 1

COVER B Q'ty

LEAD WIRE MOTOR

LEAD WIRE LEV 1

LEAD WIRE THM A 1

LEAD WIRE THM B Q'ty

LEAD WIRE EARTH 1

LEAD WIRE PUMP 1

LEAD WIRE FS 1

INSULATOR Q'ty

BAND 6

CLAMP 4

FERRITE CORE 1

SPECIFICATIONS YKB/YLM 2nd

Drive mechanism Directly driven by motor Directly driven by motor Directly driven by motor Directly driven by motor. 5. Measured in quiet room with a 1 m air intake duct and 2 m air outlet duct attached to the unit and 1.5 m below the unit. The above specification data is 6. Measured in silent room with a 2m air intake duct and 2m air outlet duct attached to the unit and 1.5m below the unit.

Drive mechanism Directly driven by motor° Directly driven by motor Directly driven by motor Directly driven by motor. Optional Parts Filter Box PAC-KE94TB-E PAC-KE94TB-E PAC-KE95TB-E PAC-KE92TB-E.

EXTERNAL DIMENSIONS YKB/YLM 2nd

Exhaust pipe (I.D.ø32) Entrance door ceiling surface Make the entrance door to the designated position properly for service maintenance. Coolant Air Filter Piping Fitting (Gas). OD Entrance door ceiling surface Make the entrance door to the proper position for service maintenance.

PEFY-P20VMA3-E

S 954uspension bolt

100 860(Duct) 20

CENTER OF GRAVITY YKB/YLM 2nd

ELECTRICAL WIRING DIAGRAMS YKB/YLM 2nd

S (SHIELD) ACL Connector (0-10V Analog input) Connector (IT terminal) Connector (emergency operation) Switch (for static pressure selection) Switch (for static pressure selection) Switch (BRANCH No.) Switch (10th digit address set) Switch (1s digit address set)Switch (for mode selection)Switch (for model selection)Switch (for mode selection)Switch (for capacity code)Switch (for mode selection)Thermistor (pipe temp. detection/gas)Thermistor (pipe temp. .detection/liquid).

SOUND LEVELS YKB/YLM 2nd

PEFY-P-VMA(L)-E, VMA3-E

PEFY-P-VMA(L)-E

PEFY-P20,25VMA(L)-E External Static Pressure: 35Pa

PEFY-P20,25VMA(L)-E External Static Pressure: 50Pa

PEFY-P20,25VMA(L)-E External Static Pressure: 70Pa

PEFY-P20,25VMA(L)-E External Static Pressure: 100Pa

PEFY-P20,25VMA(L)-E External Static Pressure: 150Pa

PEFY-P32VMA(L)-E External Static Pressure: 35Pa

PEFY-P32VMA(L)-E External Static Pressure: 50Pa

PEFY-P32VMA(L)-E External Static Pressure: 70Pa

PEFY-P32VMA(L)-E External Static Pressure: 100Pa

PEFY-P32VMA(L)-E External Static Pressure: 150Pa

PEFY-P40VMA(L)-E External Static Pressure: 35Pa

PEFY-P40VMA(L)-E External Static Pressure: 50Pa

PEFY-P40VMA(L)-E External Static Pressure: 70Pa

PEFY-P40VMA(L)-E External Static Pressure: 100Pa

PEFY-P40VMA(L)-E External Static Pressure: 150Pa

PEFY-P50VMA(L)-E External Static Pressure: 35Pa

PEFY-P50VMA(L)-E External Static Pressure: 50Pa

PEFY-P50VMA(L)-E External Static Pressure: 70Pa

PEFY-P50VMA(L)-E External Static Pressure: 100Pa

PEFY-P50VMA(L)-E External Static Pressure: 150Pa

PEFY-P63VMA(L)-E External Static Pressure: 35Pa

PEFY-P63VMA(L)-E External Static Pressure: 50Pa

PEFY-P63VMA(L)-E External Static Pressure: 70Pa

PEFY-P63VMA(L)-E External Static Pressure: 100Pa

PEFY-P63VMA(L)-E External Static Pressure: 150Pa

PEFY-P71,80VMA(L)-E External Static Pressure: 35Pa

PEFY-P71,80VMA(L)-E External Static Pressure: 50Pa

PEFY-P71,80VMA(L)-E External Static Pressure: 70Pa

PEFY-P71,80VMA(L)-E External Static Pressure: 100Pa

PEFY-P71,80VMA(L)-E External Static Pressure: 150Pa

PEFY-P100VMA(L)-E External Static Pressure: 35Pa

PEFY-P100VMA(L)-E External Static Pressure: 50Pa

PEFY-P100VMA(L)-E External Static Pressure: 70Pa

PEFY-P100VMA(L)-E External Static Pressure: 100Pa

PEFY-P100VMA(L)-E External Static Pressure: 150Pa

PEFY-P125VMA(L)-E External Static Pressure: 35Pa

PEFY-P125VMA(L)-E External Static Pressure: 50Pa

PEFY-P125VMA(L)-E External Static Pressure: 70Pa

PEFY-P125VMA(L)-E External Static Pressure: 100Pa

PEFY-P125VMA(L)-E External Static Pressure: 150Pa

PEFY-P140VMA(L)-E External Static Pressure: 35Pa

PEFY-P140VMA(L)-E External Static Pressure: 50Pa

PEFY-P140VMA(L)-E External Static Pressure: 70Pa

PEFY-P140VMA(L)-E External Static Pressure: 100Pa

PEFY-P140VMA(L)-E External Static Pressure: 150Pa

PEFY-P71, 80VMA(L)-E External Static Pressure: 35Pa

PEFY-P71, 80VMA(L)-E External Static Pressure: 50Pa

PEFY-P71, 80VMA(L)-E External Static Pressure: 70Pa

PEFY-P71, 80VMA(L)-E External Static Pressure: 100Pa

PEFY-P71, 80VMA(L)-E External Static Pressure: 150Pa

FAN CHARACTERISTICS CURVES YKB/YLM 2nd

PEFY-P20,25VMA(L)-E External static pressure : 35Pa

PEFY-P20,25VMA(L)-E External static pressure : 50Pa

PEFY-P20,25VMA(L)-E External static pressure : 70Pa

PEFY-P20,25VMA(L)-E External static pressure : 100Pa

PEFY-P20,25VMA(L)-E External static pressure : 150Pa

PEFY-P32VMA(L)-E

PEFY-P40VMA(L)-E

PEFY-P50VMA(L)-E

PEFY-P63VMA(L)-E

PEFY-P71,80VMA(L)-E External static pressure : 35Pa

PEFY-P71,80VMA(L)-E External static pressure : 50Pa

PEFY-P71,80VMA(L)-E External static pressure : 70Pa

PEFY-P71,80VMA(L)-E External static pressure : 100Pa

PEFY-P71,80VMA(L)-E External static pressure : 150Pa

PEFY-P100VMA(L)-E

PEFY-P125VMA(L)-E

PEFY-P140VMA(L)-E

OPTIONAL PARTS YKB/YLM 2nd

7-2. Filter box

FLANGE

PEFY-P- VMH-E-F

PEFY-E-F

PEFY-E- F

2.Keep the service space for maintenance from the ground up when the heat exchanger is cleaned.

PEFY-P80,140,200,250VMH-E-F

PEFY-P80VMH-E-F PEFY-P140VMH-E-F

PEFY-P80, 140VMH-E-F

Power Source Terminal Bed Indoor Thermostat49F Over Current Relay (Blower Motor) Contactor (Blower Motor) Switch (For Voltage Selection) Aux.

PEFY-P200, 250VMH-E-F

PEFY-P80VMH-E-F

PEFY-P140VMH-E-F External static pressure : 35Pa

PEFY-P140VMH-E-F External static pressure : 85Pa

PEFY-P140VMH-E-F

PEFY-P140VMH-E-F External static pressure : 50Pa

PEFY-P140VMH-E-F External static pressure : 60Pa

PEFY-P200VMH-E-F

PEFY-P250VMH-E-F

External static pressure (Pa) External static pressure (Pa)External static pressure (Pa)External static pressure (Pa)External static pressure (Pa) External static pressure (Pa).

7-1. Cooling capacity

7-3. Heating capacity

8-1. Optional parts line up for the Indoor unit

PEFY-P-VMH-E-F

8-3. Drain pump

PMFY-P-VBM-E

PMFY

14 (31) MUNSELL (0.98Y 8.99/0.63)

PMP-40BMW

PMP-40BMWDecoration panel

PMFY-P20, 25, 32, 40VBM-E

PMFY-P20VBM-E PMFY-P25VBM-E

LEGEND]

P25VBM

P32VBM

P40VBM

B INDOOR CONTROLLER BOARD CN25

B CIRCUIT BOARD SW1

NOTES

LEVM

PMFY-P20VBM-E

PMFY-P25, 32VBM-E External static pressure : 0Pa

PMFY-P40VBM-E

TEMPERATURE/AIRFLOW DISTRIBUTIONS YKB/YLM 2nd

6-1. Temperature distributions

PMFY-P20-40VBM-E

6-2. Airflow distributions

PMFY-P20-40VBM-EC

PLFY-P-VLMD-E

PLFY

1 Nominal cooling conditions *2 Nominal cooling conditions *3 Nominal heating conditions Installation manual, Instruction book Exhaust pipe I.D.

PLFY-P125VLMD-E

PLFY-P63VLMD-E PLFY-P80VLMD-E

PLFY-P20VLMD-E PLFY-P25VLMD-E

TRANSMISSION TERMINAL BED ) TO MA REMOTE CONTROLLER TO OUTDOOR UNIT Refrigerant distributor ME REMOTE CONTROLLER TB2. Connector (central control) Connector (remote indication) Connector (central control) Connector (HA terminal-A) Auxiliary relay (L notch: 240 V). Connection (damper) aristorransmission connection bed Remote control connection bed Ransformer Thermistor (inlet temp. sense) Thermistor (pipe/liquid temp. sense) Thermistor (pipe/gas temp. sense) Switch (set address 1-digit number) Switch (set address 10th digits ) Switch (set connection no.) Switch (for selecting mode 1) Switch (for selecting model) Switch (for capacity code) Switch (for selecting mode 2) Aux. relay (notch M/L: 240 V/220-230 V) Auxiliary .relay (H/M slot: 240V/220-230V) Auxiliary relay (H slot: 220-230V) Switch (for selecting mode 3) Switch (for selecting voltage).

Electronic linear expansion valve Internal control board Address board Power connector Power connector Power connector Transfer connector Fuse AC250V 6.3 A F Transformer Drain pump Vane motor (with limit switch) Drain sensor Thermistor (inlet temperature detection) Switch (set address 1s). ). Fan motor NAME Thermistor (pipe temp. detection / liquid) Thermistor (pipe temp. detection / gas) Switch (10th place address set) Switch (Connection No. set) Switch (for mode selection) Switch (for performance code) Switch ( option) parts) Switch (for mode selection) SW4(I.B) Switch (for model selection).

INSIDE SECTION OF TERMINAL

PLFY-P20,25VLMD-E External static pressure : 0Pa

PLFY-P32VLMD-E

PLFY-P40VLMD-E

PLFY-P50VLMD-E

PLFY-P63VLMD-E

PLFY-P80VLMD-E

PLFY-P100VLMD-E External static pressure : 0Pa

PLFY-P125VLMD-E External static pressure : 0Pa

OA INTAKE-STATIC PRESSURE CURVES YKB/YLM 2nd

Confirm that the inlet air temperature (mixed with outside air) is within the following operating temperature range.

BRANCH DUCT INTAKE-STATIC PRESSURE CURVES YKB/YLM 2nd

TEMPERATURE/AIRFLOW DISTRIBUTIONS YKB/YLM 2nd

8-1. Temperature distributions

PLFY-P20-125VLMD-E

8-2. Airflow distributions

OPTIONAL PARTS YKB/YLM 2nd

9-1. Optional parts line up for the Indoor unit

9-2. OA duct flange

0.050PLFY-P20VBM-E

22 (49) PLP-6BA

PS PP honeycomb

R410A CITY MULTI

23 (51) PLP-6BA

23(51) PLP-6BA

27(60) PLP-6BA

PLFY-P15, 20, 25, 32, 40VCM-E2

In case of wireless remote control: PLP-6BALM In case of standard grille: PLP-6BA.

Connected the attached

The height of the indoor unit is able to be adjusted with the grille attached

Requires E or more space between transom and ceiling for the installation

Add 135 mm to the dimensions * marked on the figure

When installing the branch ducts, be sure to insulate adequately

PLFY-P15VCM-E2

PLFY-P20VCM-E2 PLFY-P25VCM-E2

PLFY-P20VBM-E PLFY-P25VBM-E

B INDOOR CONTROLLER BOARD CN32

B OPTION PART

B PCB FOR WIRELESS REMOTE CONTROLLER

B GRILLE

M LEV

2. If you use the MA remote control, connect it to TB15. (The remote control wire is non-polar.) 3. If you use M-NET, connect it to TB5. 4.Symbol [S] of TB5 is the connection of the shielded wire. 5. The symbols used in the above wiring diagram are: terminal block,: connector.

PLFY-P-VCM-E2, VBM-E

PLFY-P15VCM-E2 PLFY-P20VCM-E2

PLFY-P20VCM-E2

PLFY-P25VCM-E2

PLFY-P32VCM-E2

PLFY-P40VCM-E2

PLFY-P32VBM-E

PLFY-P40VBM-E

PLFY-P50VBM-E

PLFY-P63VBM-E

PLFY-P125VBM-E

PLFY-P80VBM-E

PLFY-P100VBM-E

PLFY-P15-40VCM-E2

PLFY-P20-80VBM-E

PLFY-P100, 125VBM-E

PLFY-P-VBM-E

7-2. Air outlet shutter plate

7-3. High efficiency filter element

4Shape

7-6. Automatic filter elevation panel

UP/DOWN Machine 2

7-7. Wireless signal receiver

7-8. Space panel

7-9. Duct flange for fresh air intake

1 Insulator

3 Screws (M4 x 10)

PCFY-P-VKM-E

PCFY

PCFY-P40VKM-E

PCFY-P63VKM-E

PCFY-P100,125VKM-E

PCFY-P40,63,100,125VKM-E

PCFY-P40VKM-E PCFY-P63VKM-E

PCFY-P40, 63, 100, 125VKM-E

At servicing for outdoor unit, always follow the wiring diagram of outdoor unit

In case of using MA-Remote controller, please connect to TB15

NET CN2M

U.M (BLU)CNP

PCFY-P40VKM

PCFY-P63VKM

PCFY-P100VKM

PCFY-P125VKM

PCFY-P100, 125VKM-E

TEMPERATURE/AIRFLOW DISTRIBUTIONS YKB/YLM 2nd

PCFY-P40, 63VKM-E

7-2. Airflow distributions Airflow distributions

8-2. High efficiency filter

8-4. Wireless remote controller kit

PCFY-P63VKM-E PCFY-P100,125VKM-E

PAR-SL94B-E

PKFY

FAN Type x Number Line flow fan x 1 Line flow fan x 1 Line flow fan x 1 Line flow fan x 1. Remarks * Details of foundation work, duct work, insulation work, electrical wiring, power source switch and other items must be referred to the installation instructions. Address card The first page The second page Transmission (DC 24-30V) MA remote control (DC8.7-13V) There is no MA remote control terminal block.

In case of MA remote control connection, please connect the MA remote control cable (accessory) to the connector. Power supply (220-240 V). Transmission Power supply Address table Detailed Address setting digit Mode selection * The address table is protected with the PL cover. Required space (indoor unit) Min.50 Min.220 Min.150550 mm or larger with optional drain pump installation.

Terminal block for power supply Terminal block for transmission Terminal block for MA remote control Emergency control switch (cooling / heating) Under sideVane (auto) Operating lamp 612. DEFROST / STABD BY lamp Operating lamp. lower pipingC. 108 mm or more with left or rear left pipe or drain mechanism installation Min.

PKFY-P100VKM-EPKFY-P25VBM-E

PKFY-P63VKM-E

PKFY-P15VBM-E 815 225 225

PKFY-P40VHM-E PKFY-P50VHM-E

PKFY-P15, 20, 25VBM-E

Please set the switch SW5 according to the power supply voltage

Legend Symbol

NET (BLU)

PKFY-P32, 40, 50VHM-E

B INDOOR CONTROLLER BOARD

B ADDRESS BOARD

B SWITCH BOARD

B PCB FOR WIRELESS REMOTE CONTROLLERSW1

  • At servicing for outdoor unit,always follow the wiring diagram of outdoor unit
  • In case of using M-NET, please connect to TB5
  • Symbol [S] of TB5 is the shield wire connection

PKFY-P63, 100VKM-E

Symbol [S]of TB5 is the shield wire connection

LED2

BPULL

PKFY-P15VBM-E

PKFY-P20VBM-E PKFY-P25VBM-E

PKFY-P100VKM-EPKFY-P40VHM-E

PKFY-P20, 25VBM-E External Static Pressure: 0Pa

PKFY-P32VHM-E

PKFY-P40VHM-E

PKFY-P50VHM-E

PKFY-P100VKM-E External Static Pressure: 0Pa

PKFY-P32-50VHM-E

PKFY-P15-25VBM-E

7-2. External LEV Box

PFFY

28 (62) Sirocco fan x 1

30 (67) Sirocco fan x 2

32 (71) Sirocco fan x 2

Model

36 (80) Sirocco fan x 2

37 (82) Sirocco fan x 2

22 (49) Sirocco fan x 1

24 (53) Sirocco fan x 2

25 (56) Sirocco fan x 2

29 (64) Sirocco fan x 2

21 (47) Sirocco fan x 1

24 (53) Sirocco fan x 2

PFFY-P20, 25, 32, 40VKM-E2

PFFY-P20VLRM-EModel name

PFFY-P25VLRM-E PFFY-P32VLRM-E

PFFY-P20VLEM-E PFFY-P25VLEM-E

PFFY-P20VLRMM-E PFFY-P25VLRMM-E

MODELS P20VBM

At servicing for outdoor unit,always follow the wiring diagram of outdoor unit

The setting of the SW2 dip switches differs in the capacity. For the detail, refer to the table below

Please set the switch SW5 according to the power supply voltage

SYMBOL I. B

POWER SUPPLY (I.B) POWER SUPPLY (I.B)

FAN MOTOR (UPPER) FAN MOTOR (LOWER)

SYMBOL

OPTION SELECTORNAME

ADDRESS BOARD

MARK

FUNCTION LED1

TO NEXT INDOOR UNIT Switch (connection no.) Switch (address assignment of 10 digits) Thermistor (pipe temperature.detection/gas) Thermistor (pipe temperature.detection/liquid) Switch (for mode selection ). Switch (digit address assignment 1) Thermistor (input temperature. Detection) Address board Internal controller board Capacitor (for MF) Fan motor NAME SYMBOL Electronic linear expansion. INSIDE CONTROL BOX SECTION Only PFFY -P63VLRMM-E BARK OPERATION FOR INTERNAL CONTROL BOARD SERVICE DEPUTY.

Switch (for mode selection) Switch (for model selection) Switch (10th digit address set) Switch (connection number set) Switch (for static pressure selection) Switch (for static pressure selection) Thermistor (pipe temperature detection/gas) Thermistor (pipe temperature/liquid detection ) Transmission terminal bedTB15TB2 TB5 Transmission terminal bed Power source terminal bed AC reactor (power factor improvement).

PFFY-P20, 25VLEM-E, VLRM-E External static pressure : 0Pa

PFFY-P32VLEM-E, VLRM-E External static pressure : 0Pa

PFFY-P40VLEM-E, VLRM-E External static pressure : 0Pa

PFFY-P25, 32VKM-E2 External static pressure : 0Pa

PFFY-P40VKM-E2