CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021Solicitante / Applicant
SIEMENS AG
SIMATIC Type Test Karlsruhe
Östliche Rheinbrückenstraße 50, DE-76187 Karlsruhe - Germany CNPJ: Não aplicável / Not applicable
Audit File: A28521 (date 2018-10-17)
FILE#/VOL.#/SEC.#
BR3419/Vol.1/Sec.15
Local de Montagem / Assembly Location
Não aplicável / Not applicable
Importador / Importer
Não aplicável / Not applicable
Marca Comercial / Trademark
Não aplicável / Not applicable
Produto Certificado / Certified Product
SISTEMA DE DISTRIBUIÇÃO I/O, SISTEMA-BASE FORMADO POR
TM-PS-., TM-../.. ...E AM
DISTRIBUTED I/O SYSTEM, BASE-SYSTEM FORMED BY TM-PS-., TM-../.. ... AND AM
Modelo / Model
ET 200iSP
Lote ou Número de Série / Lot or Serial Number
Não aplicável / Not applicable
Marcação / Marking
Ex e [ia Ga/ib][ia IIIC Da] IIC T4 Gb
Ex e [ia/ib] I Mb
Normas Aplicáveis / Applicable Standards
ABNT NBR IEC 60079-0:2013
ABNT NBR IEC 60079-7:2008
ABNT NBR IEC 60079-11:2013
ABNT NBR IEC 60079-26:2016
Programa de certificação ou Portaria /
Certification Program or Ordinance
Portarias no. 179, de 18 de maio de 2010 e nº. 89 de 23 de fevereiro de 2012 do
INMETRO
INMETRO Ordinances nº 179 as of May 18, 2010 and nº 89 as of Feb 23, 2012.
Concessão Para / Concession for
Ostentar o Selo de Identificação da Conformidade do Sistema Brasileiro de
Avaliação da Conformidade (SBAC) sobre o(s) produto(s) relacionado(s) neste
certificado.
Bearing the Conformity Identification Seal of the Brazilian System of Conformity (SBAC) on the product covered by this certificate.
Delzuite M. Ferreira Jr.
Gerente de Operações / Operations Manager
UL do Brasil Certificações, organismo acreditado pela Coordenação Geral de
Acreditação do INMETRO – CGCRE, segundo o registro No.: OCP-0029 confirma
que o produto está em conformidade com a(s) Norma(s) e programas ou
Portarias acima descritas.
UL do Brasil Certificações , Certification Body accredited by Coordenação Geral de Acreditação do INMETRO - CGCRE according to the register No.: OCP-0029 confirms that the product is in compliance with the standards and certification Program or Ordinance above mentioned.
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021Fabricante / Manufacturer
SIEMENS AG
PD PA MF-K
Östliche Rheinbrückenstraße 50, DE-76187 Karlsruhe - Germany CNPJ: Não aplicável / Not applicable
Audit File: A28521 (date 2018-10-17)
MODELO DE CERTIFICAÇÃO / CERTIFICATION MODEL:
☒
Modelo com Avaliação do Sistema de Gestão da Qualidade do Processo de Produção do Produto e Ensaios no Produto
Quality Management System Evaluation of the Product Production Process and Product Test Model
☐
Modelo Ensaio de Lote
Lot Test Model
CÓDIGO DE BARRAS GTIN / GTIN BAR CODE:
Não aplicável /
Not applicableDESCRIÇÃO DO PRODUTO / PRODUCT DESCRIPTION:
O Sistema de Distribuição I/O modelo ET 200iSP converte sinais de campo em sinais digitais, e este para aqueles adequados para
processamento de dados e controle. Ele consiste de uma configuração modular dos módulos abaixo descritos e do módulo,
certificado separadamente, para uso no Sistema de Distribuição I/O.
Os módulos TM-PS-. inclui TM-PS-A, modelo 6ES7 193-7DA00-0AA0 e modelo 6ES7 193-7DA10-0AA0, TM-PS-A UC, modelo
6ES7 193-7DA20-0AA0, TM-PS-B, modelo 6ES7 193-7DB00-0AA0 e modelo 6ES7 193-7DB10-0AA0 e TM-PS-B UC modelo
6ES7 193-7DB20-0AA0. Estes módulos terminais são projetados para a conexão de uma Fonte de Alimentação.
Os módulos TM-../.. ... inclui TM-IM/IM, modelo 6ES7 193-7AB00-0AA0, TM-IM/EM, modelo 6ES7 193-7AA00-0AA0, modelo 6ES7
193-7AA20-0AA0, TM-IM/EM 60C, modelo 6ES7 193-7AA10-0AA0, TM-EM/EM 60S, modelo 6ES7 193-7CA00-0AA-0, modelo
6ES7 193-7CA20-0AA0 e TM-EM/EM 60C, modelo 6ES7 193-7CA10-0AA0.
Os módulos TM-IM/EM 60S, TM-IM/EM 60C, TM-EM 60S e TM-EM/EM 60C conectam um ou dois módulos eletrônicos,
certificados separadamente para uso no Sistema de Distribuição I/O. Este grupo de módulos é referido com o acrônimo TM-EM.
Os módulos TM-IM/IM, TM-IM/EM 60S e TM-IM/EM 60C conectam um ou dois módulos de interface, certificados separadamente
para uso no Sistema de Distribuição I/O. Este grupo de módulos é referido com o acrônimo TM-IM.
O módulo de terminação AM é um módulo com o qual a extremidade direita do Sistema-Base é terminada. Um módulo TM-PS-.
forma a extremidade esquerda do Sistema-Base.
O Sistema-Base é formado pela interconexão dos módulos TM-PS-., TM-../.. ... e AM, que são mecanicamente fixados a um trilho
metálico de montagem. O Sistema-Base contém os seguintes circuitos internos conforme listado em dados elétricos:
Circuito de Potência Bus, Circuito de Alimentação IM, Circuito de Dados e circuitos como definidos no Certificado de Conformidade
Inmetro de um módulo, separadamente certificado para uso no Sistema de Distribuição I/O.
Os módulos TM-PS-. são executados com circuitos no tipo de proteção segurança aumentada de acordo com a ABNT NBR IEC
60079-7 e intrinsecamente seguros de acordo com a ABNT NBR IEC 60079-11.
Módulos TM-../.. ... e AM são executados com os circuitos no tipo de proteção segurança intrínseca de acordo com a ABNT NBR
IEC 60079-11.
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021Módulos certificados separadamente para uso no Sistema de Distribuição I/O são executados em um tipo de proteção,
especificado no respectivo Certificado de Conformidade Inmetro, onde adequabilidade para uma atmosfera explosiva diferente
pode ser especificada.
Faixa de temperatura ambiente:
-20 °C a +70 °C (Posição horizontal de montagem)
-20 °C a +50 °C (Todas as outras posições de montagem)
The Distributed I/O System type ET 200iSP converts field signals into digital signals, and is by that suitable for data processing and control. It consists of a modular configuration of the modules described below and of modules, separately certified for use in the Distributed I/O System.
The modules TM-PS-. include TM-PS-A, type 6ES7 193-7DA00-0AA0 and type 6ES7 193-7DA10-0AA0, TM-PS-A UC, type 6ES7 193-7DA20-0AA0, TM-PS-B, type 6ES7 193-7DB00-0AA0 and type 6ES7 193-
7DB10-0AAO and TM-PS-B UC type 6ES7 193-7DB20-0AA0. These terminal modules are intended for the connection of a Power Supply.
The modules TM-.i include TM-IM/IM, type 6ES7 193-7AB00-0AA0, TM-IM/EM 60S, type 6ES7 193-7AA00-0AA0, type 6ES7 193-7AA20-0AAO, TM-IM/EM 60C, type 6ES7 193-7AA10-0AA0, TM-EM/EM 60S, type 6ES7 193-7CA00-0AA0, type 6ES7 193-7CA20-0AA0 and TM-EM/EM 60C, type 6ES7 193-7CA10-0AA0.
The modules TM-IM/EM 60S, TM-IM/EM 60C, TM-EM/EM 60S and TM-EM/EM 60C connect one or two electronic modules, separately certified for use in the Distributed I/O System. This group of modules is referred to with the acronym TM-EM.
The modules TM-IM/IM, TM-IM/EM 60S and TM-IM/EM 60C connect one or two interface modules, separately certified for use in the Distributed I/O System. This group of modules is referred to with the acronym TM-IM.
Termination module AM is a module with which the right end of the Base-System is terminated. A module TM-PS-. forms the left end of the Base-System.
The Base-System is formed by the interconnection of modules TM-PS-., TM-..I and AM, that are mechanically secured to a metal mounting rail. The Base-System contains the following internal circuits as listed at the electrical data:
Power Bus circuit, IM Supply circuit, Data circuit and circuits as defined in the lECEx Certificate of Conformity of a module, separately certified for use in the Distributed I/O System.
Modules TM-PS-. are executed with circuits in types of protection increased safety in accordance with ABNT NBR IEC 60079-7 and intrinsic safety in accordance with ABNT NBR IEC 60079-11.
Modules TM-../ and AM are executed with circuits in type of protection intrinsic safety in accordance with ABNT NBR IEC 60079-11.
Separately certified modules for use in the Distributed I/O System are executed in a type of protection, as specified in the espective lnmetro Certificates of Conformity, where suitability for a different explosive atmosphere may be specified.
Ambient temperature range:
-20 °C to +70 °C (Horizontal mounting position), -20 °C to +50 °C (all other mounting positions).
CARACTERÍSTICAS ELÉTRICAS / ELECTRICAL CHARACTERISTICS:
Sistema de Distribuição I/O modelo ET 200iSP, sistema-base formado pelos módulos TM-PS-., TM-../.. ... e AM.
Circuito de alimentação terminais L+, M e PA (conectado através do TM-PS-.):
No tipo de proteção segurança aumentada Ex e, apenas para conexão dos módulos certificados para uso no Sistema de
Distribuição I/O.
Para TM-PS-.:
U = 30 Vcc máximo; I = 5 A máximo
Para TM-PS-.UC:
U = 264 Vca máximo; I = 5 A máximo
Circuito de Potência Bus (conectado através do TM-../.. ... e TM-PS-.):
No tipo de proteção segurança intrínseca Ex ib IIC, apenas para conexão dos módulos certificados para uso no Sistema de
Distribuição I/O.
Corrente máxima 15 A (térmica)
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021No tipo de proteção segurança intrínseca Ex ib IIC, apenas para conexão dos módulos certificados para uso no Sistema de
Distribuição I/O.
Circuito de dados (conectado através do TM-../.. ... e TM-PS-.):
No tipo de proteção segurança intrínseca Ex ib IIC, apenas para conexão dos módulos certificados para uso no Sistema de
Distribuição I/O.
Distributed I/O System type ET 200iSP,
Base-System formed by modules TM-PS-., TM-../ and AM: Supply circuit terminals L+, M and PA (connected through TM-PS-.):
in type of protection increased safety Ex e, only for connection of modules certified for use in the Distributed I/O System.
For TM-PS-.:
U = 30 Vdc max; I = 5 A max.
For TM-PS-. UC:
U = 264 Vac max; I = 5 A max.
Power Bus circuit (connected through TM-../ and TM-PS-.):
in type of protection intrinsic safety Ex ib IIC, only for connection of modules certified for use in the Distributed I/O System. Maximum current 15 A (thermal)
IM Supply circuit (connected through TM-../ and TM-PS-.):
in type of protection intrinsic safety Ex ib IIC, only for connection of modules certified for use in the Distributed I/O System. Data circuit (connected through TM-../ and TM-PS-.):
in type of protection intrinsic safety Ex ib IIC, only for connection of modules certified for use in the Distributed I/O System.
CONDIÇÕES ESPECÍFICAS DE UTILIZAÇÃO PARA EQUIPAMENTOS Ex ou LISTA DE LIMITAÇÕES PARA
COMPONENTES Ex:
SPECIFIC CONDITIONS OF USE FOR Ex EQUIPMENT or SCHEDULE OF LIMITATIONS FOR Ex COMPONENTS:
Nenhuma
/
NoneENSAIOS DE ROTINA / ROUTINE TESTS:
Os seguintes ensaios de rotina devem ser conduzidos pelo fabricante e serão verificados durante as auditorias conduzidas pela
UL:
The following routine tests shall be conducted by the manufacturer and will be verified during the audits conducted by UL:
O módulo TM-PS-. deve ser submetido ao ensaio de rigidez dielétrica de acordo com o descrito no documento A5E00283883B.
O módulo TM-PS-. UC deve ser submetido ao ensaio de rigidez dielétrica de acordo com o descrito no documento A5E00283883L.
The modules TM-PS-. shall be subjected to a dielectric strength test in accordance with description A5E00283883B.CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021LISTA DE DOCUMENTOS / DOCUMENTS LIST:
☒Description ILL#
☐TestRef ILL#
Título / Title:
Desenho Nº
Drawing No.:Revisão ou Data:
Issue or Date01
Montage + Beschriftung
A5E00481160A
07
02
Montage + Beschriftung
A5E00481159A
07
03
Montage + Beschriftung
A5E02040184C
03
04
Montage + Beschriftung
A5E02040185C
03
05
Part List TM-lM_EM
A5E02655090
01
06
Part List TM-EM_EM
A5E02654291
01
07
Technical Description
A5E002B3884L
01
08
Tech. Beschreibung Anderung 01/09
A5E00283883L
01
09
PCB assembly TM-PS A UC
A5E02040182
02
10
TM-PS A UC (ET200iSP)
A5E02040181A
02
11
PCB assembly TM-PS B UC
A5E02040183
02
12
TM-PS B UC (ET200|SP)
A5E02040181
02
13
ET2OO|S-2/ TM-PS UC
A5E00283883M
01
14
Sicherheitstechn. Beschreibung
A5E00283883N
01
15
TM-PS UC Schaltablauf
A5E00283883R
01
16
TM-PS UC
A5E00283883Q
01
17
Schaltkontakt TM-PS
A5E02389298A
02
18
Fem. Connector F48 flat solder (A5E02430282B_001)
374217
2008-12-16
19
Circuit Diagram
A5E02224188A
01
20
Circuit Diagram
A5E02223592A
01
21
Parts list
A5E02224188
01
22
Parts list
A5E02325336
01
23
Parts list
A5E02325337
01
24
Print layout
A5E00283884M
01
25
Constructional drawing
A5E00283883C
01
26
Plug/removal drawing
A5E00283883D
01
27
Layout TM-PS
A5E00283883E
01
28
Schematic TM-PS
A5E00203632A
04
29
Parts list type TM-PS-A
A5E00328524
02
30
Parts list type TM-PS-B
A5E00328525
02
31
Power Bus connector
A5E00207939A
02
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021☒Description ILL#
☐TestRef ILL#
Título / Title:
Desenho Nº
Drawing No.:Revisão ou Data:
Issue or Date33
Layer constructional drawing
A5E00149500E
02
34
Marking of TM-PS-A
A5E00251200B
02
35
Marking of TM-PS-B
A5E00251201B
02
CERTIFICADO DE CONFORMIDADE, RELATÓRIOS DE ENSAIO / CERTIFICATE OF CONFORMANCE, TEST
REPORTS:
☒TestRec DS# ☐TestRef DS#Título/Descrição:
Title/Description:Documento Nº
Document No.:Revisão ou Data:
Issue or Date01
Certificado IECEx
IECEx KEM 05.0003
8
02
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/00
2006-05-31
03
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/00
2006-05-31
04
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/00
2006-05-31
05
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/00
2006-05-31
06
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/00
2006-05-31
07
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/03
2008-11-28
08
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/03
2008-11-28
09
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/04
2009-03-12
10
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/04
2009-03-12
11
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/04
2009-03-12
12
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/04
2009-03-12
13
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
14
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
15
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
16
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
17
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
18
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
19
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/05
2009-07-15
20
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/06
2009-09-30
21
Relatório de ensaio, Kema Qualiy B.V., IECEx Test Report
NL/KEM/EXTR06.0025/07
2012-08-22
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade
/
Expire date 05 de dezembro de 2021 / December 05, 2021OBSERVAÇÕES / OBSERVATIONS:
1. Este certificado aplica-se aos produtos idênticos ao protótipo avaliado e certificado, manufaturados na(s) unidade(s) fabril(is)
mencionada(s) neste certificado, sendo este válido apenas para produtos fabricados/produzidos após a sua emissão.
2. Qualquer alteração no produto, incluindo a marcação, invalidará o presente certificado, salvo se o solicitante informar por escrito à
UL do Brasil Certificações sobre esta modificação, a qual procederá à avaliação e decidirá quanto à continuidade da validade do
certificado.
3. Somente as unidades comercializadas durante a vigência deste certificado estarão cobertas por esta certificação.
4. Os equipamentos devem ser instalados em atendimento ás Normas pertinentes em Instalações Elétricas em Atmosferas
Explosivas, ABNT NBR IEC 60079-14.
5. As atividades de instalação, inspeção, manutenção, reparo, revisão e recuperação dos equipamentos são de responsabilidade dos
usuários e devem ser executadas de acordo com os requisitos das normas técnicas vigentes e com as recomendações do
fabricante.
6. É de competência do solicitante estabelecido fora do país notificar o representante legal para fins de comercialização no Brasil,
importador ou o próprio usuário sobre as responsabilidades e obrigações prescritas na Cláusula 10 da Portaria 179:2010.
7. A validade deste Certificado de Conformidade está atrelada à realização das avaliações de manutenção e tratamento de possíveis
não conformidades de acordo com as orientações da UL do Brasil Certificações previstas no RAC específico. Para verificação da
condição atualizada de regularidade deste Certificado de Conformidade deve ser consultado o banco de dados de produtos e
serviços certificados do Inmetro.
1. This certificate applies to the products that are identical to the prototype investigated, certified and manufactured at the production site(s) mentioned in this certificate, being valid only for products produced/manufactured after its issuance.
2. Any changes made on the product, including marking, will invalidate this certificate unless UL do Brasil Certificações is notified, in written, about the desired change, who will conduct an analyzes and will decide over the continuity of the certificate validity.
3. Only the products placed into the market during the validity of this certificate will be covered by this certification.
4. The equipment shall be installed according to the relevant Standards in Electrical Installation for Explosive Atmospheres, ABNT NBR IEC 60079-14.
5. The installation, inspection, maintenance, repair, review and rebuild equipment activities are responsibility of the end user and must be performed in accordance with the requirements of the standards and manufacturer's recommendation.
6. If the applicant is established outside of Brazil it is their responsibility to notify the legal representative for commercial purposes in Brazil, importer or end user of the responsibilities and obligations described in Clause 10 of Portaria 179:2010.
7. The validity of this Certificate of Conformity is subjected to the conduction of the maintenance evaluations and treatment of possible nonconformities according to UL do Brasil Certificações guidelines in accordance with the specific RAC. In order to verify the updated condition of validity of this Certificate of Conformity, the Inmetro database of certified products and services must be consulted.
CERTIFICADO DE CONFORMIDADE
CERTIFICATE OF CONFORMITY
Certificado No. /
Certificate No.
UL-BR 12.0077
Certificado de Conformidade válido somente acompanhado das páginas de:Certificate of Conformity valid only with the following pages:
1 a 8
Emissão
/
Date of issue 06 de dezembro de 2012 / December 06, 2012Revisão
/
Revision Date 05 de dezembro de 2018 / December 5, 2018Validade