1
Edenir Rodrigues Pereira Filho
Professor Associado 4 da Universidade Federal de São Carlos (UFSCar)
erpf@ufscar.br
https://www.youtube.com/c/EdenirPereiraFilho
linkedin.com/in/edenir-pereira-filho-ele-o-8846382b https://www.instagram.com/erpereirafilho/
https://www.facebook.com/planEdenir www.gaia.ufscar.br
Planejamento Fatorial (Design of Experiments,
DoE): Estudos de Casos
2
O mestrado profissional em
química da UFSCar
MESTRADO PROFISSIONAL:
PPGQ / UFSCar
www.ppgq.ufscar.br (Conceito 5 da Capes)
3
4
APRESENTAÇÃO DO CURSO
➢ O CURSO DE MESTRADO PROFISSIONAL DO PPGQ-UFSCar É
GRATUITO E DIRIGIDO AOS PROFISSIONAIS
*ATUANTES EM EMPRESAS OU EM INSTITUIÇÕES DE ENSINO SECUNDÁRIO &
FUNDAMENTAL
*
DIPLOMADOS EM CURSOS DE GRADUAÇÃO DE QUÍMICA OU ÁREA CORRELATA
PÚBLICO ALVO
5
Mestrado Profissional (Estabelecido em 2008)
Ensino de Química Química Tecnológica
Foco desta apresentação Informações em
www.ppgq.ufscar.br
6
OBJETIVOS
➢ O MESTRADO PROFISSIONAL VISA POSSIBILITAR AO PÓS-
GRADUANDO CONDIÇÕES PARA O DESENVOLVIMENTO DE UMA PRÁTICA PROFISSIONAL TRANSFORMADORA, POR MEIO DA
INCORPORAÇÃO DO MÉTODO CIENTÍFICO E DA APLICAÇÃO DOS CONHECIMENTOS DE NOVAS TÉCNICAS E PROCESSOS
7
8
Experiências e Aplicações
9
O que vem pela frente?
10
O que é fato:
✓ Todos os alunos que orientei estão ganhando
mais...
11
O que é fato:
✓ A empregabilidade aumentou;
✓ Aumentaram as possibilidades de crescimento e mudança para posições melhores;
✓ O aluno possui uma visão diferenciada quando
comparado com o período antes do ingresso no
mestrado;
12
Minha opinião:
✓ Existem muitos problemas para serem resolvidos;
✓ A demanda por soluções é alta;
✓ As opções para os alunos em potencial são poucas;
✓ O diálogo setores produtivo e acadêmico precisa ser melhorado;
✓ Há muito para aprender com as diferentes visões (industrial e acadêmica) e ambos os lados só tem a ganhar;
✓ O aluno do mestrado profissional requer um acompanhamento diferente daquele do
acadêmico;
✓ O aluno terá uma agenda mais movimentada.
13
Caso 1
UNIVERSIDADE FEDERAL DE SÃO CARLOS - UFSCar Centro de Ciências Exatas e de Tecnologia - CCET
Departamento de Química - DQ
Programa de Pós-Graduação em Química - PPGQ Grupo de Análise Instrumental Aplicada - GAIA
Application of Design of Experiments (DoE) to Dissolution Method Development in Pharmaceutical
Industry
Mestrando: Renato Cesar de Souza (Pesquisador Científico) Orientador: Prof. Dr. Edenir Rodrigues Pereira Filho
◼ THERAPEUTIC EQUIVALENCE
Therapeutic equivalence: Same efficiency and safety effects after administration
Substituted if their therapeutic response are equal
Active Ingredient A
Brand
Active Ingredient A
Generic
15
◼ IN VITRO DISSOLUTION TEST
Stomach pH 1.5 – 4.0
(Acid) Tablet in
particles
Dissolved in molecular state
Absorbed to bloodstream
Gut pH 7-8
Tablet
Sampling point
A
Vessel
Paddle
(b) Dosage
form
◼ DISSOLUTION METHOD DEVELOPMENT
Evaluated by One Factor At Time method
(OFAT)
Excess of information with weak conclusion.
• Manual x automatic Basket vs
Paddle
• SLS Heated
• pH testing time
• Buffer prep
• Ionic strengh
• Buffer capacity
• pH
• pH drifting during test
• SLS conc
• HCl x Phosporic acid
• Analyst
• Day • Wavelenght
• Temperature
• Electrode pH
• pH meter
• Plastic vs glass
• Standard stability
• Standard prep
• SLS Vendor • SLS Quality
• Lot
• Strenght
• Age
• Vessel position
• Vessel position
• RPM
• Basket mesh size
• Bubbles on basket
• Sampling time
• Filter
• Sample location
Variables involved in a dissolution method development
17
DISSOLUTION METHOD DEVELOPMENT
Development of a dissolution method for a extended release drug product
Evaluation of 4 variables (Apparatus. Rotation speed. Volume and pH of the dissolution media)
• Nº of tests: 38
• Quantity of samples (tablets) 228
• Days to test execution 40
• Costs (R$) ???
• Necessity to reduce time and costs in dissolution method development
• Optimize data evaluation
◼ MATERIAL AND METHODS
The product: Zolpidem Hemitartrate Controled Release (12.5 mg/comp) Therapeutic Class: Hypnotic
Therapeutic Indication: Treatment of insomnia – start and/or maintaining sleep
Biphasic dissolution Immediate release
layer
Extended Release Layer
Reference product used to method development
19
◼ RESULTS AND DISCUSSION Risk Assessment (FMEA)
Selected four factors:
x1: Apparatus rotation speed (rpm) x2: pH of the dissolution media x3: Dissolution media volume x4: Apparatus (I or II)
Factors
Level
-1 1
50 rpm 100 rpm
2.0 6.8
500 mL 900 mL
Paddle Basket
◼ RESULTS AND DISCUSSION
Paddle apparatus. no stirring (Mauger et al. 2003) Basket apparatus. no stirring (Mauger et al. 2003)
Screening study – Factorial Design
21
◼ RESULTS AND DISCUSSION
Factorial Screen Design
Total of 16 experiments with 3 repetitions
Apparatus, x1 Rotation speed
(rpm), x2 pH, x3 Volume (mL), x4
Paddle 100 2.0 900 51.02 87.64 0.969 0.78 1.99
Basket 100 2.0 500 51.81 96.03 0.975 0.92 2.25
Paddle 100 6.8 500 47.13 80.66 0.951 0.53 1.84
Basket 100 6.8 500 49.38 89.78 0.959 0.61 2.03
Paddle 50 2.0 900 47.08 86.57 0.957 0.53 2.00
Paddle 50 2.0 500 47.07 92.49 0.965 0.63 2.15
Basket 50 2.0 900 43.02 90.69 0.975 0.69 2.30
Basket 50 6.8 900 37.72 82.08 0.962 0.40 2.19
Basket 50 2.0 500 44.38 97.16 0.979 0.65 2.31
Paddle 50 6.8 500 42.80 76.63 0.962 0.54 1.89
Paddle 100 2.0 500 52.58 89.77 0.970 0.81 1.95
Paddle 100 6.8 900 56.64 94.09 0.952 0.72 1.95
Basket 50 6.8 500 32.80 84.29 0.964 0.25 2.35
Basket 100 2.0 900 52.13 94.99 0.973 0.98 2.26
Paddle 50 6.8 900 43.65 80.13 0.962 0.63 1.97
Basket 100 6.8 900 54.35 97.88 0.960 0.79 2.19
◼ RESULTS AND DISCUSSION
Design-Expert® Sof tware ALFA
A: Apparatus B: Rotation Speed C: pH
D: Volume
Positiv e Ef f ects Negativ e Ef f ects
X2: t-Value of Ef f ectX1: Rank
0.00 2.59 5.19 7.78 10.38
Bo n fe r r o n i L imit 3 .1 3 7 8 7
t- Va lu e L imit 2 .0 2 6 1 9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
B C
A B
A C D CD
A B C
• All factors are important
• Rotation speed
• Negative effect of pH
• Secondary and terciary interactions
Full factorial Experiment – Important Effects – α parameter
23
RESULTS AND DISCUSSION
Optimization Study – Response Surface Model FCC
Factors Level
-1 0 1
50 75 100
2.0 4.4 6.8
500 700 900
• + 8 experiments with 3 repetitions
• Model the factors
• Find the best dissolution condition based on desiribility criteria
◼ RESULTS AND DISCUSSION
Response surface Model
ANOVA with a signficance level of 0.05
Factor Response
Coefficient p-value Coefficient p-value Coefficient p-value
5.76 <1.00E-3 2.28 <1.00E-3 -2.0E-3 1.90E-1
-1.60 1.8E-02 -3.03 <1.00E-3 -8.9E-3 <1.00E-3
1.51 2.80E-2 0.29 5.85E-1 -1.8E-3 2.41E-1
2.24 3.80E-2 2.76 <1.00E-3 3.3E-4 8.46E-1
0.06 9.38E-1 1.48 1.35E-2 1.4E-4 9.35E-1
1.21 1.05E-1 1.18 4.45E-2 9.3E-4 5.82E-1
-3.07 2.33E-2 -0.55 5.94E-1 8.2E-3 1.00E-2
1.90 1.51E-1 0.99 3.37E-1 -4.1E-3 1.79E-1
-2.39 7.89E-2 -0.69 5.09E-1 7.1E-3 2.66E-2
25
◼ RESULTS AND DISCUSSION
Response DF p-value
(Model) F-Ratio R2 p-value
(LOFT)
y1 5 <0.0001 20.51 0.72 0.1200
y2 5 <0.0001 19.19 0.71 <0.0001
y3 3 <0.0001 18.23 0.56 0.0828
y4 5 <0.0001 48.18 0.86 0.1608
y5 5 <0.0001 8.13 0.50 0.3756
Model significance
50 63
75 88
100
2.00 3.20 4.40 5.60 6.80 0.430 0.578 0.725 0.873 1.020
Alfa
Rotation Speed (rpm) pH
Response y4 (α parameter of logistic model)
X: Internally Studentized Residuals Y : Normal % Probability
Normal Plot of Residuals
-2.67 -1.49 -0.31 0.86 2.04
1 5 10 20 30 50 70 80 90 95 99
X: Predicted
Y : Internally Studentized Residuals
Residuals vs. Predicted
-3.00 -1.50 0.00 1.50 3.00
0.29 0.47 0.65 0.83 1.00
◼ RESULTS AND DISCUSSION
27
◼ RESULTS AND DISCUSSION Selection of Dissolution Condition
• First approach: Desiribility Function
• In vitro dissolution curve fit to Logistic Model
• Responses: y3 (++++), y4 (++++) and y5 (+)
Design-Expert® Sof tware Desirability
1 0
X1 = A: Rotation Speed X2 = B: pH
Actual Factor C: Volume = 500.00
50 63 75 88 100
2.0 2.3 2.7 3.0
3.3 Desirability
B: pH
0.132 0.265
0.397 0.530
0.530 0.662
0.757
0.567 0.611
Dissolution condition
Apparatus: Basket
Rotation speed: 50 rpm Volume: 500 mL
Medium: HCl 0,01 M
28
◼ RESULTS AND DISCUSSION
50 63 75 88 100
2.00 3.20 4.40 5.60
6.80 Volume of 700 mL
X1: A: Rotation Speed (rpm) X2: B: pH
1: 58
1,5: 71
2: 78.6
3: 904: 95
50 63 75 88 100
2.00 3.20 4.40 5.60
6.80 Volume of 500 mL
X1: A: Rotation Speed (rpm) X2: B: pH
1: 58
1,5: 71 2: 78.6
3: 90 4: 95
50 63 75 88 100
2.00 3.20 4.40 5.60
6.80 Volume of 900 mL
X1: A: Rotation Speed (rpm) X2: B: pH
1: 68.3
1,5: 71
1,5: 71 2: 78.6
3: 90 4: 95
Selection of Dissolution Condition
Dissolution condition Apparatus: Basket
Rotation speed: 50 rpm Volume: 500 mL
Medium: HCl 0,01 M
29
◼ RESULTS AND DISCUSSION
Comparisson DOE e OFAT
OFAT DOE Reduction
Nº of tests: 38 24 37%
Nº of samples (tablets) 228 72 68%
Days to test execution 40 26 35%
Costs (R$) ??? < 50%
31
Caso 2
Desenvolvimento de método cromatográfico para a separação de três ativos e suas respectivas
impurezas utilizando ferramentas quimiométricas
Romero Moreira de Souza
Analista de Desenvolvimento Analítico
(LIBBS Farmacêutica)
Conceito de Quimiometria
➢ A quimiometria é uma área da química que utiliza conhecimentos de
matemática e estatística para a identificação de informações relevantes de um problema em estudo.
Quimiometria
33
Planejamento Fatorial
➢ Dentre as vertentes da quimiometria se encontra o emprego do planejamento fatorial (design of experiments, DoE), que permite observar os efeitos de
variáveis e interações entre elas.
Variáveis do método:
➢ Vazão da fase móvel;
➢ Temperatura do forno da coluna cromatográfica;
➢ Concentração de orgânico na fase móvel;
➢ pH da fase móvel;
➢ Composição da coluna cromatográfica (C8, C18, Phenyl, etc).
Materias e Equipamentos
A RDC 53/2015 estabelece limites para identificação das impurezas.
Trabalhando com sais e solventes
voláteis o método pode ser utilizado em espectrometria de massas para a
identificação das impurezas.
35
Tratamento dos dados
➢ Também serão tratados no programa Fusion Waters.
➢ Os resultados serão comparados com os obtidos pelo Octave.
Resultados esperados
Melhor condição para cada variável de modo a obter:
➢ Menor tempo de análise;
➢ Melhor separação entre os picos dos compostos (resolução);
➢ Pureza cromatográfica satisfatória.
37
Resultados
Foi realizada uma análise exploratória com as seguintes variáveis do método analítico:
➢ Diferentes colunas;
➢ Diferentes solventes (Metanol e Acetonitrila);
➢ Diferentes pH da fase móvel;
➢ Diferentes velocidades de gradiente (velocidade em que a concentração de orgânico na fase móvel aumenta).
Foram medidas as seguintes respostas:
➢ Número total de picos;
➢ Separação entre os picos (resolução).
Resultados
Após a avaliação dos cromatogramas das análises exploratórias, decidiu- se fixar a coluna cromatográfica (devido a dificuldade de codificar
matematicamente) e prosseguiu- se com o planejamento fatorial com duas variáveis:
➢ pH da fase móvel;
➢ Velocidade do gradiente;
E foram medidas duas respostas:
➢ Número total de picos;
➢ Número de picos com resolução maior que 1,5.
39
Resultados
Foi executado um planejamento fatorial “Face centrada” com duas réplicas de cada condição e cinco réplicas no ponto central com as seguintes variáveis:
VARIÁVEIS
VARIÁVEL 1 VARIÁVEL 2
TEMPO GRADIENTE (MIN) pH FASE MÓVEL
BAIXO -1 30 -1 2,0
PC 0 40 0 3,0
ALTO 1 50 1 4,0
Resultados
41
Matriz X (21:6)
V1 V2
TEMPO pH
Experimentos b0 b1 b2 b11 b22 b12
1 1 -1 -1 1 1 1
2 1 -1 -1 1 1 1
3 1 1 -1 1 1 -1
4 1 1 -1 1 1 -1
5 1 -1 1 1 1 -1
6 1 -1 1 1 1 -1
7 1 1 1 1 1 1
8 1 1 1 1 1 1
9 1 -1 0 1 0 0
10 1 -1 0 1 0 0
11 1 1 0 1 0 0
12 1 1 0 1 0 0
13 1 0 1 0 1 0
14 1 0 1 0 1 0
15 1 0 -1 0 1 0
16 1 0 -1 0 1 0
17 1 0 0 0 0 0
18 1 0 0 0 0 0
19 1 0 0 0 0 0
20 1 0 0 0 0 0
21 1 0 0 0 0 0
-1.5 -1 -0.5 0 0.5 1 1.5
-1.5 -1 -0.5 0 0.5 1 1.5
Resultados
Matriz y das respostas:
Matriz y (21:2)
Objetivo Maximizar
Experimentos y1
1 11
2 11
3 10
4 10
5 10
6 11
7 11
8 11
9 15
10 15
11 16
12 16
13 9
14 9
15 11
16 10
17 10
18 10
19 10
20 10
21 10
Maximizar y2 10 9 9 9 9 10
8 7 7 7 7 8 6 6 8 7 7 7 7 7 7
RESPOSTAS
y1 NÚMERO DE PICOS
y2 Nº DE PICOS COM RESOLUÇÃO >
1,5
Resultados
Tratamento dos dados no Octave:
➢ Regressão para a respostas y1 (número de picos);
➢ Regressão para a resposta y2 (numero de picos com resolução maior que 1,5);
➢ Calcular a desejabilidade de cada resposta e a desejabilidade global;
➢ Regressão com a desejabilidade global;
➢ Calculado a melhor condição de cada variável com o modelo para obter a melhor repostas (maior número de picos com maior resolução)
43
Resultados
Cálculo da desejabilidade individual de cada resposta e da desejabilidade global
Gradiente pH Respostas Desejabilidade
Experimentos Real Cod Real Cod y1 y2 d1 d2 D global
1 30 -1 2 -1 11 10 0,285714 1 0,534522
2 30 -1 2 -1 11 9 0,285714 0,75 0,46291
3 50 1 2 -1 10 9 0,142857 0,75 0,327327
4 50 1 2 -1 10 9 0,142857 0,75 0,327327
5 30 -1 4 1 10 9 0,142857 0,75 0,327327
6 30 -1 4 1 11 10 0,285714 1 0,534522
7 50 1 4 1 11 8 0,285714 0,5 0,377964
8 50 1 4 1 11 7 0,285714 0,25 0,267261
9 30 -1 3 0 15 7 0,857143 0,25 0,46291
10 30 -1 3 0 15 7 0,857143 0,25 0,46291
11 50 1 3 0 16 7 1 0,25 0,5
12 50 1 3 0 16 8 1 0,5 0,707107
13 40 0 4 1 9 6 0 0 0
14 40 0 4 1 9 6 0 0 0
15 40 0 2 -1 11 8 0,285714 0,5 0,377964
16 40 0 2 -1 10 7 0,142857 0,25 0,188982
17 40 0 3 0 10 7 0,142857 0,25 0,188982
18 40 0 3 0 10 7 0,142857 0,25 0,188982
19 40 0 3 0 10 7 0,142857 0,25 0,188982
20 40 0 3 0 10 7 0,142857 0,25 0,188982
21 40 0 3 0 10 7 0,142857 0,25 0,188982
Resultados
Tratamento dos dados no Octave:
➢ Regressão para a desejabilidade global
45
Resultados
Tratamento dos dados no Octave:
➢ Regressão para a desejabilidade global
Resultados
Tratamento dos dados no Octave:
➢ Regressão para a desejabilidade global
47
Resultados
Tratamento dos dados no Octave:
➢ Regressão para a desejabilidade global Coeficientes:
Média Mínimo Máximo IC b0 0.21106 0.12148 0.30065 0.089583 b1 -0.023176 -0.089613 0.043261 0.066437 b2 -0.05933 -0.12577 0.0071071 0.066437 b11 0.29456 0.19048 0.39865 0.10409 b22 -0.096932 -0.20102 0.007155 0.10409 b12 0.015769 -0.065599 0.097138 0.081368
Resultados
Superfície de resposta:
49
Resultados
Gráfico de contorno:
Resultados Octave
Calculando as variáveis utilizando o modelo temos:
Variável 1 (Tempo de Gradiente): 30 minutos Variável 2 (pH da fase móvel): 2,6
51
Resultados Fusion Waters
Resultados
Cromatograma:
53
Obrigado a todos pela atenção!
Contatos
e-mail: erpf@ufscar.br
Home page: http://www.gaia.ufscar.br