• Nenhum resultado encontrado

Arq. Bras. Oftalmol. vol.77 número2

N/A
N/A
Protected

Academic year: 2018

Share "Arq. Bras. Oftalmol. vol.77 número2"

Copied!
1
0
0

Texto

(1)

1 3 2 Arq Bras Oftalmol. 2014;77(2):132

Letters to the Editor

Use of the Iowa Satisfaction with

Anesthesia Scale in Portuguese

Fernandes et al.(1) used the Iowa Satisfaction with Anesthesia Scale

(ISAS) to measure patient satisfaction after cataract surgery. The ISAS generally is appropriate for cataract surgery and has content validity for monitored anesthesia care(1-3). Fung et al.(4) showed that the ISAS

can be used to measure patient satisfaction with cataract care under topical local anesthesia and monitored sedation.

However, the three previous studies that assessed the reliability and validity of ISAS were performed in English. There is a clear dis-tinction in English between the somatic “I felt pain” and the emotive “I hurt.” The authors’ Methods section does not state that the study was limited to patients who speak and write English at a 4th grade

level or higher, as applicable. The authors’ Discussion does not men-tion language. Was the instrument used in English or Portuguese? If Portuguese, what systematic processes were used for translation? What percentage of respondents answered these two questions differently? What was the internal consistency (Cronbach alpha) of the instrument? A Portuguese version of the instrument would be very helpful for future investigations.

In addition, ISAS is copyrighted by Franklin Dexter and the Uni-versity of Iowa Research Foundation. This is stated in each table of the original paper, throughout the second paper, and in each related table of the Fung et al. paper(2-4). Performing a web search with either

Google or Bing (performed February 14, 2014) using the term “Iowa Satisfaction with Anesthesia Scale” returned the authorization form for use as the first entry. What steps did the authors follow to use ISAS, and what changes do the authors recommend for the authorization process described at www.FranklinDexter.net/FAQ/FAQ_a32.htm.

Franklin Dexter

Department of Anesthesia, University of Iowa, Iowa City.

Disclosure of potential conflicts of interest: Please refer to www.FranklinDexter.net/FAQ/FAQ_a1.htm. The Iowa Satisfaction with Anesthesia Scale is copyrighted by Franklin Dexter and the University of Iowa Research Foundation. Income from the Division’s consulting work, including the Iowa Satisfaction with Anesthesia Scale scores, is used to fund Division research.

Corresponding author: Franklin Dexter. Division of Management Consulting. Department of Anes-thesia University of Iowa - 200 Hawkins Dr 6JCP - Iowa City, IA 52246 USA. +1 (319) 621-6360 - E-mail: Franklin-Dexter@UIowa.edu

Submitted for publication: February 17, 2014 Accepted for publication: February 27, 2014

REFERENCES

1. Fernandes MB, de Souza RV, Vasconcelos GC, Ribeiro KG, Andrade BB, Fernandes CR. Assessing patient satisfaction with cataract surgery under topical anesthesia supple-mented by intracameral lidocaine combined with sedation. Arq Bras Oftalmol. 2013; 76(6):345-9.

2. Dexter F, Aker J, Wright WA. Development of a measure of patient satisfaction with monitored anesthesia care: the Iowa Satisfaction with Anesthesia Scale. Anesthesio-logy. 1997;87(4):865-73.

3. Dexter F, Candiotti KA. Multicenter assessment of the Iowa Satisfaction with Anesthe-sia Scale, an instrument that measures patient satisfaction with monitored anestheAnesthe-sia care. Anesth Analg. 2011;113(2):364-8.

4. Fung D, Cohen M, Stewart S, Davies A. Can the Iowa Satisfaction with Anesthesia Scale be used to measure patient satisfaction with cataract care under topical local anesthesia and monitored sedation at a community hospital? Anesth Analg. 2005;100(6):1637-43.

Reply

The authors appreciate the thoughtful comments expressed in the letter. Authors have applied published grading system that has been used in the medical field for several situations, including tumor grading, graft rejection grading, heart failure grading (NYHSA score), criteria for diagnosing rheumatological conditions, and many other published guidelines.

We consider the Iowa Satisfaction with Anesthesia Scale (ISAS) scale as a very interesting and useful method to measure patient sa tisfaction after cataract surgery. As stated in letter, ISAS is generally appropriate for cataract surgery. The ISAS had content validity for monitored anesthesia care(1,2) and Fung et al., showed “…ISAS can be

used to measure patient satisfaction with cataract care under topical local anesthesia and monitored sedation”(3).

The internal consistency was not measured because this was an exploratory pilot study. All patients were Brazilian and spoke Por-tuguese. The instrument was applied in Portuguese and our group translated it. All authors speak Portuguese as their native language and English higher than a fourth grade level. The translation was evaluated before its submission by the company American Journal Experts. “I felt pain” was translated exactly as “I felt pain,” and “I hurt” was translated as “I hurt.” All patients who had answered that they felt pain had answered they did not hurt, and most patients had no pain and had not hurt themselves.

We are glad to know there is interest in validating ISAS in Por-tuguese. The data obtained herein would be useful for a future pilot study that might examine the reliability and validity of ISAS in Portuguese. Knowing how to best use ISAS would help investigators in future studies.

Manuela Bezerril Cipiao Fernandes

TSA, Sociedade Brasileira de Anestesia, BA, Hospital Geral de Fortaleza.

Corresponding author: Manuela Fernandes. Department of Anesthesiology. Hospital Geral de Fortaleza. Rua José Vilar, 300/1300 - Fortaleza (CE) - 60125-000 - Brazil.

E-mail: manuelabcf@terra.com.br

REFERENCES

1. Dexter F, Aker J, Wright WA. Development of a measure of patient satisfaction with mo nitored anesthesia care: the Iowa Satisfaction with Anesthesia Scale. Anesthesio-logy. 1997;87(4):865-73.

2. Dexter F, Candiotti KA. Multicenter assessment of the Iowa Satisfaction with Anesthe-sia Scale, an instrument that measures patient satisfaction with monitored anestheAnesthe-sia care. Anesth Analg. 2011;113(2):364-8.

3. Fung D, Cohen M, Stewart S, Davies A. Can the Iowa Satisfaction with Anesthesia Scale be used to measure patient satisfaction with cataract care under topical local anes thesia and monitored sedation at a community hospital? Anesth Analg. 2005; 100(6):1637-43.

Referências

Documentos relacionados

Mas a palavra também é utilizada por ele para designar o conjunto dos domínios portugueses no Novo Mundo, neste caso, de modo bastante elogioso: “nem duvida que seja em tempo breve/

This study aimed to assess and compare the visual performance of patients fitted with the artificial pupil contact lens and CBMCLC by evaluating the binocular visual acuity,

The following data also were obtained through our questionnaire: busi­ ness sector and occupation at the time of incident, number of years of work in the present sector, time

sensitivity and innervation after CXL in rabbits has also shown that corneal sensitivity was significantly decreased 3 days after UVA irra- diation with

In all patients, the forced head tilt difference was neutralized or tended to vanish when the test was performed with the patient in the supine position, while it was inverted

Most subjects (60.0%) reported the use of some optical aids to perform near and far activities, and the activities that were most often cited were reading, cleaning, cooking,

In contrast to Onal et al., who reported that education level and age afected the visual prognosis in Behçet’s disease (15) ; another study found that education, general

This study aimed to evaluate the effects of preservative-free 0.45% ketorolac tromethamine and carboxymethylcellulose com- pared with those of preservative-free artificial tears