• Nenhum resultado encontrado

RP-HPLC

Stability indicating RP-HPLC method development and validation of cefepime and amikacin in pure and pharmaceutical dosage forms

Stability indicating RP-HPLC method development and validation of cefepime and amikacin in pure and pharmaceutical dosage forms

... the HPLC methods for estimation of cefepime and amikacin in ...the RP-HPLC methods for the estimation of cefepime and amikacin in combined dosage ...

9

A validated stability-indicating RP-HPLC method for paracetamol and lornoxicam: Application to pharmaceutical dosage forms

A validated stability-indicating RP-HPLC method for paracetamol and lornoxicam: Application to pharmaceutical dosage forms

... The proposed isocratic RP-HPLC method deve- loped for the simultaneous determination of PR and LR was found to be specific, linear, precise, accurate and robust. All validation parameter results were within ...

6

Development and validation of an RP-HPLC method for quantification of trans-resveratrol in the plant extracts

Development and validation of an RP-HPLC method for quantification of trans-resveratrol in the plant extracts

... Ro ust ess of ethod. The o ust ess of ethod is i estigated i the f a e o k of ethod de elop e t as a o ept of ualit desig . The ai of the o ust ess of the de eloped RP-HPLC ethod is to e a i e the a iatio ...

9

Stability indicating RP-HPLC method for the estimation of Decitabine in bulk drug and lipid based Nanoparticles

Stability indicating RP-HPLC method for the estimation of Decitabine in bulk drug and lipid based Nanoparticles

... Purpose: The aim of our present work was to develop and validate a reverse phase high-performance liquid chromatography (RP-HPLC) method for the determination of Decitabine (DCB). The developed method was ...

9

Stationary phases for reversed phase high performance liquid chromatography (RP-HPLC) based on functionalized inorganic oxide surfaces.

Stationary phases for reversed phase high performance liquid chromatography (RP-HPLC) based on functionalized inorganic oxide surfaces.

... STATIONARY PHASES FOR REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (RP-HPLC) BASED ON FUNCTIONALIZED INORGANIC OXIDE SURFACES. Particles of porous silica or other solvent resistent inorganic oxides ...

8

Simultaneous Estimation of Lamivudine and Stavudine by using RP-HPLC and Method Development as per ICH Guidelines

Simultaneous Estimation of Lamivudine and Stavudine by using RP-HPLC and Method Development as per ICH Guidelines

... The developed RP-HPLC method was accurate, precise, reproducible and robust. The developed method has been found to be better, because of its wide range of linearity, use of a readily available mobile ...

5

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF ATENOLOL AND CHLORTHALIDONE FROM PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF ATENOLOL AND CHLORTHALIDONE FROM PHARMACEUTICAL FORMULATION

... A reverse phase high performance liquid chromatography (RP HPLC) method was developed and validated for the simultaneous estimation of atenolol and chlorthalidone in marketed formulation. The determination ...

5

METHOD DEVELOPMENT AND VALIDATION OF METFORMIN, GLIMEPIRIDE AND PIOGLITAZONE IN TABLET DOSAGE FORM BY RP-HPLC

METHOD DEVELOPMENT AND VALIDATION OF METFORMIN, GLIMEPIRIDE AND PIOGLITAZONE IN TABLET DOSAGE FORM BY RP-HPLC

... 9. Karthik A, Subramanian G, Mallikarjuna Rao C, Krishnamurthy Bhat A, Ranjithkumar, Musmade P, Surulivelrajan M, Karthikeyan K and Udupa N. Simultaneous determination of Pioglitazone and Glimepiride In bulk drug and ...

5

Development and validation of an analytical method by RP-HPLC for quantification of sibutramine hydrochloride in pharmaceutical capsules

Development and validation of an analytical method by RP-HPLC for quantification of sibutramine hydrochloride in pharmaceutical capsules

... Considering that most of these methods are time consuming and complex and some are very expensive, in the present work we have developed and validated a rapid, sensitive and economical new procedure for analysis of ...

6

Quantitative estimation of trimazolin hydrochloride in pharmaceutical preparation by RP-HPLC method

Quantitative estimation of trimazolin hydrochloride in pharmaceutical preparation by RP-HPLC method

... RP-HPLC analysis was performed by isocratic elu- tion with a flow rat of 0.8 cm 3 min -1 . The mobile phase composition was water–acetonitrile (50:50 v/v). All sol- vents were filtered through a 0.45 μm ...

7

RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF SEXAGLIPTIN AND PIOGLITAZONE IN TABLETS

RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF SEXAGLIPTIN AND PIOGLITAZONE IN TABLETS

... The Limit of Detection (LOD) and Limit of Quantification (LOQ) of the developed method were determined by injecting progressively low concentrations of the standard solutions using the developed RP-HPLC ...

4

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR FLUCONAZOLE AND IVERMECTIN IN TABLET FORMULATION BY USING RP-HPLC

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR FLUCONAZOLE AND IVERMECTIN IN TABLET FORMULATION BY USING RP-HPLC

... 7. Nalini Shastri, Pothana Sadasivudu, M. Sadanandam, ‘Development and Validation of RP-HPLC and UV methods of analysis for Fluconazole in Pharmaceutical Solid Dosage Forms’. International Journal of ...

5

Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Telmisartan and Hydrochlorothiazide in Bulk and Pharmaceutical Dosage Form

Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Telmisartan and Hydrochlorothiazide in Bulk and Pharmaceutical Dosage Form

... rapid RP-HPLC method has been developed and validated for the simultaneous estimation of Telmisartan and Hydrochlorothiazide in bulk and fixed-dosage ...

9

METHOD DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD IN THE DETECTION OF EFAVIRENZ IN BULK DRUG AND TABLET FORMULATION

METHOD DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD IN THE DETECTION OF EFAVIRENZ IN BULK DRUG AND TABLET FORMULATION

... Instrumentation: LC-20AT pump, variable wavelength programmable UV-Visible detector, Luna 5μ C-18 RP-HPLC column (250 x 4.6mm, 5 μm), Hamilton injector fitted with a 20μL loop, degasser and data processor ...

4

RP-HPLC METHOD FOR ESTIMATION OF QUETIAPINE HEMI FUMARATE IN TABLET DOSAGE FORM

RP-HPLC METHOD FOR ESTIMATION OF QUETIAPINE HEMI FUMARATE IN TABLET DOSAGE FORM

... using RP- HPLC and HPLC-EIMS in human plasma 4 ...new RP-HPLC methods for pharmaceutical formations with good accuracy, simplicity, precision and economy 5 ...

3

Development and validation of a RP–HPLC method for quantization studies of albendazole suspension dosage forms of Rombendazol

Development and validation of a RP–HPLC method for quantization studies of albendazole suspension dosage forms of Rombendazol

... A fost dezvoltat i validat o metod isocratic de lichid cromatografie de performan înalt pentru determinarea cantitativ a albendazol din suspensii Rombendazol. Separarea HPLC a fost realizat prin cromatografie în ...

3

Development and validation of a RP- HPLC method for the quantitation studies of bromadiolone in Ratitox F

Development and validation of a RP- HPLC method for the quantitation studies of bromadiolone in Ratitox F

... A fost dezvoltat i validat o metod isocratic de lichid cromatografie de performan înalt pentru determinarea cantitativ a bromadiolone din produsul Ratitox F - raticid. Separarea HPLC a fost realizat prin ...

3

Rev. bras. farmacogn.  vol.23 número6

Rev. bras. farmacogn. vol.23 número6

... the operational factors related to the chromatographic method- mobile phase flow rate, column oven temperature, percentage of organic solvent (%B) in the mobile phase, detection wavelength, and volume of sample injected ...

7

Quím. Nova  vol.37 número4

Quím. Nova vol.37 número4

... During method development, standards and samples were solu- bilized in mobile phase and placed in an ultrasonic bath at 50 °C for 30 min to ensure the extraction of GA, CAF, and EGCG. Separation of the components was ...

9

Preliminary molecular characterization of a proinflammatory and nociceptive molecule from the Echinometra lucunter spines extracts

Preliminary molecular characterization of a proinflammatory and nociceptive molecule from the Echinometra lucunter spines extracts

... The 25% ACN SPE-fraction was purified by reversed phase high performance liquid chromatography (RP- HPLC) using a binary HPLC system (20A Prominence, Shimadzu Co., Japan). The sample was loaded on a ...

8

Show all 733 documents...

temas relacionados