• Nenhum resultado encontrado

[PDF] Top 20 Validation of methods for determination of fluoxetine capsules.

Has 10000 "Validation of methods for determination of fluoxetine capsules." found on our website. Below are the top 20 most common "Validation of methods for determination of fluoxetine capsules.".

Validation of methods for determination of fluoxetine capsules.

Validation of methods for determination of fluoxetine capsules.

... VALIDATION OF METHODS FOR DETERMINATION OF FLUOXETINE ...analysis of Fluoxetine Hydrochloride ...and determination at 276 ...both methods showed to be ... See full document

5

Braz. J. Pharm. Sci.  vol.47 número3

Braz. J. Pharm. Sci. vol.47 número3

... All capsules batches were submitted to weight determination, disintegration, content uniformity assessments and evaluated according to Brazilian Pharmacopeia general methods (Farmacopéia Brasileira, ... See full document

8

Braz. J. Pharm. Sci.  vol.53 número2

Braz. J. Pharm. Sci. vol.53 número2

... Analytical methods for determination of prednisone content in tablets and active pharmaceutical ingredients (APIs), but not for capsules, have been published in the ...in capsules by ... See full document

7

Validation of chromatographic methods: an experiment using HPLC and Green Chemistry in methylxanthines determination.

Validation of chromatographic methods: an experiment using HPLC and Green Chemistry in methylxanthines determination.

... Nos estudos de seletividade do método, para cada amostra, foram preparadas duas curvas analíticas: uma com as soluções de trabalho mis- tas na faixa de concentração de 2 a 30 μg mL -1 [r] ... See full document

6

Development and validation of a dissolution test for diltiazem hydrochloride in immediate release capsules

Development and validation of a dissolution test for diltiazem hydrochloride in immediate release capsules

... in capsules was ...mL of phosphate buffer (pH ...speed of 50 rpm. The validation results demonstrated that all the data meet the acceptance criteria when both HPLC and spectrophotometry are ... See full document

7

SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF RABEPRAZOLE SODIUM AND DOMPERIDONE MALEATE IN CAPSULES BY CHEMOMETRIC METHODS

SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF RABEPRAZOLE SODIUM AND DOMPERIDONE MALEATE IN CAPSULES BY CHEMOMETRIC METHODS

... Twenty capsules were accurately weighed and powdered in a mortar. An amount of the powder equivalent was weighed and dissolved in methanol in 100ml calibrated ...20ml of methanol was added and ultra ... See full document

6

Validation of chromatographic methods for the determination of residues of veterinary drugs in foods.

Validation of chromatographic methods for the determination of residues of veterinary drugs in foods.

... A IUPAC destaca que no que diz respeito à análise de alimentos, os requerimentos para os métodos analíticos envolvem um exame das características de performance a partir de ensaios inter- laboratoriais (que envolvem ... See full document

9

Development and validation of analytical method for determination of tibolone in capsules by high performance liquid chromatography.

Development and validation of analytical method for determination of tibolone in capsules by high performance liquid chromatography.

... AND VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF TIBOLONE IN CAPSULES BY HIGH PERFORMANCE LIQUID ...prevention of bone loss and treatment of menopause ...and ... See full document

6

Development and validation of analytical method for determination of simvastatin in capsules.

Development and validation of analytical method for determination of simvastatin in capsules.

... AND VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF SIMVASTATIN IN ...content of simvastatin in capsules by UV/visible spectrophotometry (λ = 237 nm), a more affordable ... See full document

4

Evaluation Of Air Separator For Processing Particulate Chemical Industry Gas Streams

Evaluation Of Air Separator For Processing Particulate Chemical Industry Gas Streams

... number of LVs that an air separator can have and hence the higher the ...size of air separator in order to operate within optimum conditions of right LVG, AR, number of LVs, angle of LV ... See full document

6

Design And Construction Of 300W Audio Power Amplifier For Classroom

Design And Construction Of 300W Audio Power Amplifier For Classroom

... power of a ...forms of electronic circuits classed as amplifiers, from Operation Amplifier and Small Signal Amplifiers up to Large Signals and Power ...basis of most electronic systems, many ... See full document

5

The Influence of Small Amounts of Aluminium on the Spheroidization of Cast Iron with Cerium Mischmetal

The Influence of Small Amounts of Aluminium on the Spheroidization of Cast Iron with Cerium Mischmetal

... distribution of graphite precipitates (Figs 1, 3, 5, 7), as well as those showing the microstucture of cast iron (Figs 2, 4, 6, ...assessment of the influence of aluminium added in the ... See full document

6

Evaluating the influence of selected parameters on sensitivity of a numerical model of solidification

Evaluating the influence of selected parameters on sensitivity of a numerical model of solidification

... series of analyses indicate lack of dependence of certain sensitivity analysis ...case of increasing the parameter r (the number the matrix B* is generated) obtaining identical results despite ... See full document

6

Influence of supply voltage frequency of induction coil on inoculation efficiency of pure aluminium structure

Influence of supply voltage frequency of induction coil on inoculation efficiency of pure aluminium structure

... refinement of aluminium structure results from influence of rotate electromagnetic field on liquid metal in time of its solidification in ...effectiveness of inoculation fundamentally depends ... See full document

6

Assessment Of Some Acceleration Schemes In The Solution Of Systems Of Linear Equations.

Assessment Of Some Acceleration Schemes In The Solution Of Systems Of Linear Equations.

... results of the numerical experiments are presented in Tables 1 to ...the methods (the stationary methods, the accelerated schemes and the Krylov subspace acceleration methods) converged for ... See full document

8

Characteristics, complexation and analytical methods of darunavir

Characteristics, complexation and analytical methods of darunavir

... types of drugs require frequent administration in relatively high doses being the major cause of non-adherence to treatment and an obstacle to the fulfillment of pharmacotherapy ...issues of ... See full document

11

SOCIAL ECONOMY – A FORM OF INCLUSION AND OF ''REACTIVATING'' OF LABOR IN THE CONTEXT OF THE CURRENT CRISIS

SOCIAL ECONOMY – A FORM OF INCLUSION AND OF ''REACTIVATING'' OF LABOR IN THE CONTEXT OF THE CURRENT CRISIS

... context of the cohesion policy, solidarity must represent a support for development ...training of the people to whom the support of making maximum profit out of these addresses ...but, ... See full document

13

The Current State of Neoadjuvant Chemotherapy for Muscle-Invasive Bladder Cancer

The Current State of Neoadjuvant Chemotherapy for Muscle-Invasive Bladder Cancer

... outcomes of randomised trials, the rate of patients receiving NAC has seen little ...rate of the use of NAC in patients with MIBC may increase in ... See full document

6

Evaluation of susceptibility of the ZRE1 alloy to hot cracking in conditions of forced strain

Evaluation of susceptibility of the ZRE1 alloy to hot cracking in conditions of forced strain

... tests of casting welding show that the causes of high-temperature brittleness are the partial tears of the structure and the hot cracks of both the castings and the welded and padded ... See full document

6

Statistical Assessment of the Effect of Chemical Composition on Mechanical Properties of Hypereutectic AlSi17CuNiMg Silumin

Statistical Assessment of the Effect of Chemical Composition on Mechanical Properties of Hypereutectic AlSi17CuNiMg Silumin

... Taking the above into consideration, for investigations the following alloys were selected: a hypereutectic AlSi17 silumin which was “enriched” with additions of ~3%Cu, ~1,5%Ni and ~1,5%Mg (added separately or ... See full document

4

Show all 10000 documents...