Product Data Sheet
HCA38-50J
3/8" HELIFLEX
®Air-Dielectric Coaxial Cable
contained in the present datasheet is subject to confirmation at time of ordering
Product Description
3/8" HELIFLEX® Air Dielectric Coaxial Cable
HELIFLEX® 3/8" low loss air dielectric cable
Application: UHF, VHF
Features/Benefits
• Low Attenuation
The low attenuation of HELIFLEX® coaxial cable results in highly efficient
signal transfer in your RF system.
• Complete Shielding
The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
• Low VSWR
Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
• Outstanding Intermodulation Performance
HELIFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
• High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
• Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas,
wireless cellular, PCS and ESMR base stations, cabling of antenna arrays,
and radio equipment interconnects.
Frequency Attenuation Power [MHz] [dB/100m] [dB/100ft] [kW] 0.5 0.193 0.0587 16.9 1.0 0.272 0.0830 16.9 1.5 0.334 0.102 16.9 2.0 0.386 0.118 16.9 10 0.865 0.264 7.98 20 1.23 0.374 5.61 30 1.50 0.459 4.60 50 1.95 0.594 3.54 88 2.60 0.791 2.66 100 2.77 0.844 2.49 108 2.88 0.878 2.40 150 3.41 1.04 2.03 174 3.67 1.12 1.88 200 3.95 1.20 1.75 300 4.86 1.48 1.43 400 5.64 1.72 1.23 450 5.99 1.83 1.16 500 6.33 1.93 1.10 512 6.41 1.95 1.08 600 6.96 2.12 1.00 700 7.55 2.30 0.923 800 8.09 2.47 0.863 824 8.22 2.51 0.849 894 8.58 2.61 0.815 900 8.61 2.62 0.812 925 8.73 2.66 0.801 960 8.91 2.71 0.785 1000 9.10 2.77 0.769 1250 10.2 3.12 0.689 1500 11.3 3.44 0.624 1700 12.1 3.68 0.584 1800 12.4 3.79 0.571 2000 13.2 4.01 0.538 2200 13.9 4.22 0.512 2300 14.2 4.33 0.502 3000 16.4 5.0 0.439
Attenuation at 20°C (68°F) cable temperature Mean power rating at 40°C (104°F) ambient temperature
Technical Features
Structure
Inner conductor: Copper Wire [mm (in)] 3.9 (0.154)
Dielectric: [mm (in)] 8.6 (0.34)
Outer conductor: Corrugated Copper [mm (in)] 12.3 (0.484)
Jacket: Polyethylene, PE [mm (in)] 14.3 (0.563)
Mechanical Properties
Weight, approximately [kg/m (lb/ft)] 0.30 (0.2)
Minimum bending radius, single bending [mm (in)] 50 (2) Minimum bending radius, repeated bending [mm (in)] 150 (6)
Bending moment [Nm (lb-ft)] 7.0 (5.2)
Max. tensile force [N (lb)] 1000 (225)
Recommended / maximum clamp spacing [m (ft)] 0.5 / 0.5 (1.8 / 1.8)
Electrical Properties
Characteristic impedance [Ω] 50 +/- 1
Relative propagation velocity [%] 89
Capacitance [pF/m (pF/ft)] 74.0 (22.6)
Inductance [µH/m (µH/ft)] 0.185 (0.056)
Max. operating frequency [GHz] 3
Jacket spark test RMS [V] 8000
Peak power rating [kW] 16.9
RF Peak voltage rating [V] 1300
DC-resistance inner conductor [Ω/km (Ω/1000ft)] 1.44 (0.44) DC-resistance outer conductor [Ω/km (Ω/1000ft)] 1.63 (0.50)
Recommended Temperature Range
Storage temperature [°C (°F)] -70 to +85 (-94 to +185)
Installation temperature [°C (°F)] -40 to +60 (-40 to +140)
Operation temperature [°C (°F)] -50 to +85 (-58 to +185)
Other Characteristics
Fire Performance: Halogene Free
VSWR Performance: Standard [dB (VSWR)]
Typical 20.8dB (1.2:1 VSWR) or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band. Other Options: Phase stabilized and phase matched cables and assemblies are available upon request.
Technical Data Sheet
HCA158-50J
1-5/8" HELIFLEX® Air-Dielectric Coaxial Cable
RFS The Clear Choice ™
HCA158-50J
Print Date: 28.03.2005
Please visit us on the internet at http://www.rfsworld.com
Radio Frequency Systems
Product Description
HELIFLEX® 1-5/8" low loss air dielectric cable
Features/Benefits
• Low Attenuation
The low attenuation of HELIFLEX® coaxial cable results in highly efficient signal transfer in your RF
system.
• Complete Shielding
The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
• Low VSWR
Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
• Outstanding Intermodulation Performance
HELIFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
• High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized
dielectric materials, HELIFLEX® cable provides safe long term operating life at high transmit power
levels.
• Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment
interconnects.
Technical Features
Cable Type
Air-Dielectric, Corrugated
Size
1-5/8"
Jacket
Standard
Return Loss (VSWR) Performance
Standard
Maximum Return Loss, dB (VSWR)
Typical 20.8dB (1.2:1 VSWR) or better within
the operation bands of most global frequency
ranges. Premium also available. Contact
factory for options in your specific frequency
band.
Impedance, ohm
50 +/- 1
Technical Data Sheet
HCA158-50J (Cont.)
1-5/8" HELIFLEX® Air-Dielectric Coaxial Cable
Velocity, percent
95
Peak Power Rating, kW
270
Inner Conductor dc Resistance, ohm/1000 m
(ohm/1000 ft)
1.06 (0.33)
Outer Conductor dc Resistance, ohm/1000 m
(Ohm/1000 ft)
0.34 (0.11)
RF Peak Voltage, Volts
5200
Jacket Spark, Volt RMS
8000
Capacitance, pF/m (pF/ft)
70.0 (21.3)
Inductance, µH/m (µH/ft)
0.175 (0.053)
Outer Conductor Material
Corrugated Copper
Inner Conductor Material
Corrugated Copper Tube
Diameter over Jacket Nominal, mm (in)
50.4 (1.984)
Diameter Copper Outer Conductor, mm (in)
46.6 (1.83)
Diameter Inner Conductor, mm (in)
18.6 (0.73)
Diameter Dielectric, mm (in)
39.8 (1.56)
Minimum Bending Radius, Single Bend, mm (in)
180 (7)
Minimum Bending Radius, Repeated Bends, mm (in)
550 (22)
Cable Weight, kg/m (lb/ft)
1.30 (0.89)
Tensile Strength, N (lb)
1500 (337)
Recommended / Maximum Clamp Spacing, m (ft)
0.8 / 1.2 (2.75 / 4.0)
Installation Temperature, °C(°F)
-40 to +60 (-40 to +140)
Storage Temperature, °C (°F)
-70 to +85 (-94 to +185)
Operation Temperature, °C(°F)
-40 to +85 (-40 to +185)
Phase Stabilized
Phase stabilized and phase matched cables
and assemblies are available upon request.
Technical Data Sheet
HCA158-50J (Cont.)
1-5/8" HELIFLEX® Air-Dielectric Coaxial Cable
RFS The Clear Choice ™
HCA158-50J
Print Date: 28.03.2005
Please visit us on the internet at http://www.rfsworld.com
Radio Frequency Systems
Product Data Sheet
HCA400-50J
4" HELIFLEX
®Air-Dielectric Coaxial Cable
contained in the present datasheet is subject to confirmation at time of ordering
Product Description
4" HELIFLEX® Air Dielectric Coaxial Cable
HELIFLEX® 4" low loss air dielectric cable
Application: TV, Broadcast
Features/Benefits
• Low Attenuation
The low attenuation of HELIFLEX® coaxial cable results in highly efficient
signal transfer in your RF system.
• Complete Shielding
The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
• Low VSWR
Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
• Outstanding Intermodulation Performance
HELIFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
• High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
• Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas,
wireless cellular, PCS and ESMR base stations, cabling of antenna arrays,
and radio equipment interconnects.
Frequency Attenuation Power [ MHz ] [ dB/100m ] [ dB/100ft ] [ kW ] 0.5 0.0245 0.0075 792 1.0 0.0346 0.0106 561 1.5 0.0425 0.0129 457 2.0 0.0491 0.0150 395 10 0.111 0.0337 175 20 0.158 0.0480 123 30 0.194 0.0591 100 50 0.252 0.0769 77.4 88 0.338 0.103 57.9 100 0.362 0.110 54.1 108 0.377 0.115 52.0 150 0.448 0.136 44.0 174 0.484 0.148 40.8 200 0.521 0.159 38.0 300 0.648 0.198 30.9 400 0.757 0.231 26.7 450 0.808 0.246 25.1 500 0.856 0.261 23.8 512 0.867 0.264 23.6 600 0.946 0.288 21.8 700 1.03 0.314 20.2 800 1.11 0.339 18.9 824 1.13 0.344 18.6 894 1.18 0.360 18.0 900 1.19 0.362 17.8 925 1.21 0.367 17.6 960 1.23 0.375 17.3 1000 1.26 0.384 17.0
Attenuation at 20°C (68°F) cable temperature Mean power rating at 40°C (104°F) ambient temperature
Technical Features
Structure
Inner conductor: Corrugated Copper Tube [mm (in)] 34.8 (1.37) Dielectric: Helical Polyethylene Spacer [mm (in)] 75.3 (2.96) Outer conductor: Corrugated Copper [mm (in)] 85.5 (3.36)
Jacket: Polyethylene, PE [mm (in)] 90.5 (3.56)
Mechanical Properties
Weight, approximately [kg/m (lb/ft)] 3.1 (2.1)
Minimum bending radius, single bending [mm (in)] 380 (15) Minimum bending radius, repeated bending [mm (in)] 1100 (43)
Bending moment [Nm (lb-ft)] 215 (159)
Max. tensile force [N (lb)] 1800 (405)
Recommended / maximum clamp spacing [m (ft)] 0.8 / 1.2 (2.75 / 4.0)
Electrical Properties
Characteristic impedance [Ω] 50 +/- 0.5
Relative propagation velocity [%] 96
Capacitance [pF/m (pF/ft)] 70.0 (21.3)
Inductance [µH/m (µH/ft)] 0.175 (0.053)
Max. operating frequency [GHz] 1.66
Jacket spark test RMS [V] 8000
Peak power rating [kW] 940
RF Peak voltage rating [V] 9700
DC-resistance inner conductor [Ω/km (Ω/1000ft)] 0.43 (0.13) DC-resistance outer conductor [Ω/km (Ω/1000ft)] 0.13 (0.04)
Recommended Temperature Range
Storage temperature [°C (°F)] -70 to +85 (-94 to +185)
Installation temperature [°C (°F)] -40 to +60 (-40 to +140)
Operation temperature [°C (°F)] -50 to +85 (-58 to +185)
Other Characteristics
Fire Performance: Halogene Free
VSWR Performance: Standard [dB (VSWR)]
Typical 20.8dB (1.2:1 VSWR) or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band. Other Options: Phase stabilized and phase matched cables and assemblies are available upon request.
Product Data Sheet
HCA618-50J
6 1/8" HELIFLEX
®Air-Dielectric Coaxial Cable
All information contained in the present datasheet is subject to confirmation at time of ordering
RFS The Clear Choice ®
HCA618-50J
Rev: C0 / 09.Oct.2007
Please visit us on the internet at http://www.rfsworld.com/ Radio Frequency Systems
Product Description
6 1/8" HELIFLEX® Air Dielectric Coaxial Cable
HELIFLEX® 6-1/8" low loss air dielectric cable
Application: TV, Broadcast
Features/Benefits
• Low Attenuation
The low attenuation of HELIFLEX® coaxial cable results in highly efficient
signal transfer in your RF system.
• Complete Shielding
The solid outer conductor of HELIFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
• Low VSWR
Special low VSWR versions of HELIFLEX® coaxial cables contribute to low system noise.
• Outstanding Intermodulation Performance
HELIFLEX® coaxial cable’s solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
• High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, HELIFLEX® cable provides safe long term operating life at high transmit power levels.
• Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas,
wireless cellular, PCS and ESMR base stations, cabling of antenna arrays,
and radio equipment interconnects.
Frequency Attenuation Power [ MHz ] [ dB/100m ] [ dB/100ft ] [ kW ] 0.5 0.0128 0.0039 2500 1.0 0.0181 0.0055 1770 1.5 0.0222 0.0068 1440 2.0 0.0256 0.0078 1250 10 0.0578 0.0176 554 20 0.0822 0.0251 390 30 0.101 0.0308 318 50 0.132 0.0401 243 88 0.176 0.0538 183 100 0.189 0.0575 171 108 0.196 0.0599 165 150 0.233 0.0711 139 174 0.252 0.0770 129 200 0.272 0.0829 120 300 0.338 0.103 97.0 400 0.395 0.120 83.6 450 0.421 0.128 78.8 500 0.446 0.136 74.7 512 0.452 0.138 73.7 600 0.493 0.150 68.1 700 0.537 0.164 63.0 800 0.579 0.176 58.9 824 0.588 0.179 58.1 860 0.602 0.184 56.9
Attenuation at 20°C (68°F) cable temperature Mean power rating at 40°C (104°F) ambient temperature
Technical Features
Structure
Inner conductor: Corrugated Copper Tube [mm (in)] 67.0 (2.63)
Dielectric: [mm (in)] 147.0 (5.78)
Outer conductor: Corrugated Copper [mm (in)] 162.0 (6.37)
Jacket: Polyethylene, PE [mm (in)] 169.0 (6.65)
Mechanical Properties
Weight, approximately [kg/m (lb/ft)] 10.0 (6.7)
Minimum bending radius, single bending [mm (in)] 1000 (39) Minimum bending radius, repeated bending [mm (in)] 1500 (59)
Bending moment [Nm (lb-ft)] 1000 (738)
Max. tensile force [N (lb)] 6000 (1349)
Recommended / maximum clamp spacing [m (ft)] 1.0 / 2.0 (3.3 / 6.6)
Electrical Properties
Characteristic impedance [Ω] 50 +/- 0.5
Relative propagation velocity [%] 97
Capacitance [pF/m (pF/ft)] 69.0 (21.0)
Inductance [µH/m (µH/ft)] 0.173 (0.053)
Max. operating frequency [GHz] 0.86
Jacket spark test RMS [V] 8000
Peak power rating [kW] 2890
RF Peak voltage rating [V] 17000
DC-resistance inner conductor [Ω/km (Ω/1000ft)] 0.17 (0.052) DC-resistance outer conductor [Ω/km (Ω/1000ft)] 0.044 (0.013)
Recommended Temperature Range
Storage temperature [°C (°F)] -70 to +85 (-94 to +185)
Installation temperature [°C (°F)] -40 to +60 (-40 to +140)
Operation temperature [°C (°F)] -50 to +85 (-58 to +185)
Other Characteristics
Fire Performance: Halogene Free
VSWR Performance: Standard [dB (VSWR)]
Typical 20.8dB (1.2:1 VSWR) or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band. Other Options: Phase stabilized and phase matched cables and assemblies are available upon request.
Especificação
Técnica
Código:
132.001
Rev.: --
Data:
05/99
Descrição do produto:
HF 7/8” Cu2y - 50 Ohms
Aplicação
Sistemas de radiodifusão, telecomunicações e microondas (AM, FM, telefonia, etc).
Construção
Condutor interno:
Tubo de cobre nu 9,1 mm
Isolação :
Hélice de Polietileno 20,1 mm
Condutor externo:
Tubo de cobre nu corrugado 25,4 mm
Capa :
Polietileno compacto (cor preta) 29,0 mm
Características Elétricas
Resistência ôhmica do condutor interno (a 20 C):
0,77 /km
Resistência ôhmica do condutor externo(a 20 C) :
0,6 /km
Resistência de isolamento:
5000 M . km
Tensão de pico de RF:
2,7 kV
Potência de pico:
73 kW
Capacitância nominal:
71 pF / m
Velocidade relativa de propagação:
93 %
Impedância característica:
50
Freqüência de Corte:
6000 MHz
Faixa de operação:
3000 MHz
Perda de retorno na faixa 10 - 500 MHz:
23,1 dB
Perda de retorno na faixa 500 - 1000 MHz:
23,1 dB
Freqüência (MHz)
30
100
500
1000
2000
3000
Atenuação*(dB/100m)
0,64
1,18
2,72
3,9
5,8
7,2
*Temperatura em 20 C .Variação da atenuação em torno de 20 C: 0,2 % / C
Freqüência (MHz)
0,5
100
500
1000
Potência * ( kW)
73
6,8
2,99
2,08
*Potência nominal a 40 C.
Características Mecânicas
Raio mínimo de Curvatura:
100 mm para dobramento único
250 mm para dobramentos repetidos
Força de tração:
2000 N
Peso:
870 kg/km
Máxima Pressão de operação:
0,5 bar
Máxima distância entre as camisas puxadeiras:
70 m
Distância entre abraçadeiras em condições
Normais:
0,9 m
Críticas:
0,5 m
Faixa de temperatura durante a instalação:
0 a + 60 C
Acondicionamento
Sujeito a alterações sem prévio aviso
Tel.: + 55-11 7961.2433 RFS Brasil-kmP Cabos Especiais e Sistemas Ltda.
Fax : + 55-11 494.2937
BR 116 - km 279, Caixa Postal 146
06801-970 Embu - São Paulo (Brasil)
Especificação
Técnica
Código:
132.002
Rev: --
Data:
05/99
Descrição do produto:
HF 1.5/8” Cu2y - 50 Ohms
Aplicação
Sistemas de radiodifusão, telecomunicações e microondas (AM, FM, telefonia, etc).
Construção
Condutor interno:
Tubo de cobre nu corrugado 18,5 mm
Isolação :
Hélice de Polietileno 39,7 mm
Condutor externo:
Tubo de cobre nu corrugado 46,5 mm
Capa :
Polietileno compacto (cor preta) 51,0 mm
Características Elétricas
Resistência ôhmica do condutor interno (a 20 C):
1,1 /km
Resistência ôhmica do condutor externo(a 20 C) :
0,31 /km
Resistência de isolamento:
5000 M . km
Tensão de pico de RF:
5,2 kV
Potência de pico:
270 kW
Capacitância nominal:
70 pF / m
Velocidade relativa de propagação:
95 %
Impedância característica:
50
Freqüência de Corte:
3100 MHz
Faixa de operação:
3000 MHz
Perda de retorno na faixa 10 - 500 MHz:
23,1 dB
Perda de retorno na faixa 500 - 1000 MHz:
23,1 dB
Freqüência (MHz) 0,5 1,0 1,6 3,0 6,0 10 20 30 50 100 150 200 300 400 450 500 800 1000
Atenuação (dB/100m) 0,0245 0,035 0,044 0,060 0,086 0,111 0,158 0,194 0,252 0,36 0,45 0,52 0,65 0,76 0,81 0,86 1,11 1,26
Potência (kW) 790 560 440 320 227 176 124 101 78 54 44 38 31 26,3 24,7 23,4 18,1 16,0