• Nenhum resultado encontrado

bone-to-implant contact

Nanomechanical properties of bone around  cement-retained abutment implants. A minipig study

Nanomechanical properties of bone around cement-retained abutment implants. A minipig study

... direct bone to implant contact (BIC) without interposed soft tissues (13) and has been quantified throughout the years by histology/histomorphometry ...ability to predict implant ...

7

Impact of dental implant insertion method on the peri-implant bone tissue: Experimental study

Impact of dental implant insertion method on the peri-implant bone tissue: Experimental study

... in bone tissue over extended period of time, ...was to histopathologically compare the impact of the surgical method of implant insertion on the peri-implant bone ...of bone ...

10

J. Appl. Oral Sci.  vol.23 número1

J. Appl. Oral Sci. vol.23 número1

... Results: Bone formation was observed in contact with all implants without statistically signiicant differences among the evaluated surfaces in terms of bone-to-implant contact, ...

5

Braz. Dent. J.  vol.19 número1

Braz. Dent. J. vol.19 número1

... evaluated bone response to a Ca- and P- enriched titanium (Ti) surface treated by a multiphase anodic spark deposition coating ...postimplantation, bone fragments containing the implants were ...

6

Clinics  vol.66 número6

Clinics vol.66 número6

... direct bone (toluidine blue-stained) deposition on the implant surface without any other detectable tissue inter- ...total bone area of the tibia section was evaluated by software that determines the ...

5

EFFECT OF PLATFORM SWITCHING ON MARGINAL BONE RESORPTION AROUND THE IMPLANT

EFFECT OF PLATFORM SWITCHING ON MARGINAL BONE RESORPTION AROUND THE IMPLANT

... morphology to that which is found around natural ...tissue contact was found between the apical extension of the junctional epithelium and the alveolar bone comprising the first ...

60

Osseointegração de implantes em defeitos circunferenciais utilizando proteínas angiogênicas...

Osseointegração de implantes em defeitos circunferenciais utilizando proteínas angiogênicas...

... transferred to 70% ethanol solution, where they remained for three ...circumferential bone defect region (Leica DMLB ® , Leica Microsystems GmbH, Wetzlar, ...the bone- implant contact ...

123

Braz. Dent. J.  vol.16 número1

Braz. Dent. J. vol.16 número1

... (4- to-8-µm-thick) were ...greater bone-implant contact for HA-coated implants ...of bone content inside the screw implants showed no significant differences ...of bone content ...

7

Porous Titanium Associated with CaP Coating: In Vivo and In Vitro Osteogenic Performance

Porous Titanium Associated with CaP Coating: In Vivo and In Vitro Osteogenic Performance

... the implant types (P<0.05). G1 (dense implant without CaP coating) presented the lowest amount of new bone, differing from other groups, whereas G6 (porous implant with 40% porosity and CaP ...

10

Braz. Dent. J.  vol.24 número3

Braz. Dent. J. vol.24 número3

... CW, contact mode. LLLT was repeated every other day during 2 weeks. To avoid systemic effect, only one limb of each rabbit was double ...new bone formation with consequent increase of ...

6

J. Appl. Oral Sci.  vol.18 número4

J. Appl. Oral Sci. vol.18 número4

... after implant installation, and histomorphometric analysis was performed in order to measure the degree of ...including implant (N=30) were prepared for histomorphometric ...images to a ...

6

Universidade Fernando Pessoa Faculdade de Ciências da Saúde Porto, 2016

Universidade Fernando Pessoa Faculdade de Ciências da Saúde Porto, 2016

... led to the detailed microscopic characterization of interfacial bone formation at machined titanium endosseous ...of bone formation at the endosseous implant surface, known as osseointegration ...

68

J. Appl. Oral Sci.  vol.24 número4

J. Appl. Oral Sci. vol.24 número4

... adjacent to the original IP-CHA block (sample A1) as a 12-week sample (sample ...parent bone site in the femur, and the implant was then placed into the socket (Figure ...the implant was in ...

7

Bone substitutes for peri-implant defects of postextraction implants

Bone substitutes for peri-implant defects of postextraction implants

... alternative to try to reduce physiological resorption of alveolar ridge ater tooth ...used to preserve the bone architecture and also accelerate the restorative ...between bone and ...

8

Bone-implant contact around crestal and subcrestal dental implants submitted to immediate and conventional loading

Bone-implant contact around crestal and subcrestal dental implants submitted to immediate and conventional loading

... aims to evaluate the inluence of apicocoronal position and immediate and conventional loading in the percentage of bone-implant contact ...relation to the ridge: Bone Level (at ...

6

Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices

Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices

... had to be matched in the SRμCT ...order to rotate the SRμCT volume for each sample in the x- and y-axis to determine the best matching orientation to the corresponding histological ...

12

Braz. Dent. J.  vol.15 número2

Braz. Dent. J. vol.15 número2

... for bone deposit were ...New bone formation in periosteal and cortical regions linked to the implant did not vary significantly between the ...new bone formation in the medullar canal ...

6

Braz. Dent. J.  vol.21 número5

Braz. Dent. J. vol.21 número5

... sites. Bone and a layer of soft tissue were observed in close contact with the implant surfaces in the medullary ...parallel to implant ...higher bone formation than Bioglass ® ...

7

Cerâmica  vol.59 número352

Cerâmica vol.59 número352

... uence bone activity, and much of the research has been directed towards the study of factors that modulate the bone ...functions. Bone is a dynamic tissue that provides support for the body against ...

6

Neutrophil Responses to Sterile Implant Materials.

Neutrophil Responses to Sterile Implant Materials.

... prior to phase contrast imaging, or were fixed in 2% paraformaldehyde (in PBS) for 4 ...contrast to the entire image (including control samples), (ii) cropping images to limit the region of interest ...

16

Show all 10000 documents...

temas relacionados