• Nenhum resultado encontrado

[PDF] Top 20 A gas diffusion sequential injection system for the determination of sulphur dioxide in wines

Has 10000 "A gas diffusion sequential injection system for the determination of sulphur dioxide in wines" found on our website. Below are the top 20 most common "A gas diffusion sequential injection system for the determination of sulphur dioxide in wines".

A gas diffusion sequential injection system for the determination of sulphur dioxide in wines

A gas diffusion sequential injection system for the determination of sulphur dioxide in wines

... into the manifold in order to separate the analyte in its gaseous form from the complex ...matrix. In previous SIA applica- tions, the two channels of the ... See full document

8

Sequential injection flow system with improved sample throughput: determination of glycerol and ethanol in wines

Sequential injection flow system with improved sample throughput: determination of glycerol and ethanol in wines

... into the holding coil, after flow reversal, the stacked zones were sent through the loop where the GlyDH reactor was ...operations, the loop containing the ADH reactor was ... See full document

8

Flow injection system with gas diffusion for the sequential determination of total nitrogen and phosphorus in vegetables

Flow injection system with gas diffusion for the sequential determination of total nitrogen and phosphorus in vegetables

... parameters in the gas-diffusion ...optimisation of flow injec- tion gas-diffusion systems [22], equal flow-rates for the donor and acceptor streams were ... See full document

6

Kinetic determination of Image (−)malic acid in wines using sequential injection analysis

Kinetic determination of Image (−)malic acid in wines using sequential injection analysis

... at the results for individual samples, absolute deviations between the reference procedure and the proposed methodology were only higher than ...). The concentra- tions obtained for these two ... See full document

8

Use of tetramethylbenzidine for the spectrophotometric sequential injection determination of free chlorine in waters

Use of tetramethylbenzidine for the spectrophotometric sequential injection determination of free chlorine in waters

... separation. The reagent used in that determination was a non-selective, mildly pollutant reagent (o-dianisidine) whereas the matrix separation prevented any possible interfer- ence of ... See full document

6

Automatic flow systems based on sequential injection analysis for routine determinations in wines

Automatic flow systems based on sequential injection analysis for routine determinations in wines

... circumvented in the spec- trophotometric SIA system described for the determination of primary amino acid concentration during wine fermenta- tion ...[11]. In this case, ... See full document

7

Coupling a gas diffusion cell to a sequential injection system for spectrophotometric determination of sulfide.

Coupling a gas diffusion cell to a sequential injection system for spectrophotometric determination of sulfide.

... A GAS DIFFUSION CELL TO A SEQUENTIAL INJECTION SYSTEM FOR SPECTROPHOTOMETRIC DETERMINATION OF ...a gas diffusion cell to a sequential injection ... See full document

5

Spectrophotometric determination of carbon dioxide and sulphur dioxide in wines by flow injection

Spectrophotometric determination of carbon dioxide and sulphur dioxide in wines by flow injection

... assess the accu- racy of the developed method in a wider application ...carbon dioxide concentration corresponded to three different ranges of the analysed sam- ples were ... See full document

6

Sequential injection system for the spectrophotometric determination of reducing sugars in wines

Sequential injection system for the spectrophotometric determination of reducing sugars in wines

... A sequential injection system for the spectrophotometric determination of reducing sugars in wines is ...described. The methodology is based on the ... See full document

8

Gas diffusion sequential injection system for the spectrophotometric determination of free chlorine with o-dianisidine

Gas diffusion sequential injection system for the spectrophotometric determination of free chlorine with o-dianisidine

... approach in flow analysis results from both the tendency for the use of less toxic and pol- luting reagents as well as minimisation of effluent ...a system for free chlorine ... See full document

6

Development of sequential injection enzymatic and bead injection assays in lab on valve format

Development of sequential injection enzymatic and bead injection assays in lab on valve format

... Outro objectivo principal foi o de explorar as potencialidades destes sistemas de fluxo em espectrofotometria em fase sólida, demonstrando a sua adequação a amostras com matrizes normalmente complexas. Este processo, na ... See full document

267

Sequential injection titration of chloride in milk with potentiometric detection

Sequential injection titration of chloride in milk with potentiometric detection

... FIA, sequential injection analysis (SIA) was proposed by Ruzicka and Marshall ...during the transport process to the detection system, which involves an inversion of the ... See full document

5

Use of a single air segment to minimise dispersion and improve mixing in sequential injection: turbidimetric determination of sulphate in waters

Use of a single air segment to minimise dispersion and improve mixing in sequential injection: turbidimetric determination of sulphate in waters

... . In fact, the reaction kinetic, the extent of interference (from both cationic and anionic species) as well as the structure and solubility of the BaSO 4 precipitate ... See full document

7

Interpretation of the mechanism diffusion in the gas-solid process of the dessulfurization reaction.

Interpretation of the mechanism diffusion in the gas-solid process of the dessulfurization reaction.

... O calcário CI calcinado por apresentar mesoporos com diâmetro médio de 0,01µm, durante o processo de dessulfurização o bloqueio dos poros pode ocorrer mais rapidamente, consequentement[r] ... See full document

6

Carbon dioxide gas angiography.

Carbon dioxide gas angiography.

... [r] ... See full document

2

Turbidimetric determination of homatropine methylbromide in pharmaceutical formulations using a flow injection analysis system.

Turbidimetric determination of homatropine methylbromide in pharmaceutical formulations using a flow injection analysis system.

... TURBIDIMETRIC DETERMINATION OF HOMATROPINE METHYLBROMIDE IN PHARMACEUTICAL FORMULATIONS USING A FLOW INJECTION ANALYSIS ...flow injection turbidimetric procedure exploiting merging ... See full document

4

Aqueous phase oxidation of sulphur dioxide by ozone in cloud droplets

Aqueous phase oxidation of sulphur dioxide by ozone in cloud droplets

... is the maximum condensable water during the expansion, derived from the dew point temperature (T dew ) and T min .... The median drop diameter (modelled) is the largest size reached by ... See full document

54

Simultaneous determination of tartaric acid and potassium in wines using a multicommuted flow system with dialysis

Simultaneous determination of tartaric acid and potassium in wines using a multicommuted flow system with dialysis

... duced in the manifold in order to minimize matrix interferences for tartaric acid determination, so that samples could be intro- duced in the flow system directly, without ... See full document

7

Determination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing column

Determination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing column

... amounts of cadmium, which poses environ- mental problems, requiring several sample handling steps, and requiring permanent trained laboratory ...and the increasing demand for rapid analysis led to ... See full document

6

Demonstrating the fundamentals, potentialities and limitations of sequential injection analysis.

Demonstrating the fundamentals, potentialities and limitations of sequential injection analysis.

... As etapas descritas a seguir são baseadas no esquema de apare- lhagem de injeção seqüencial mostrado na Figura 2. Inicialmente, a bobina coletora (BC) e a bobina de reação (BR), assim como a bobina de diluição (BD), são ... See full document

5

Show all 10000 documents...

temas relacionados