Fraturas da extremidade proximal do úmero: estudo comparativo entre dois métodos de fixação

N/A
N/A
Protected

Academic year: 2021

Share "Fraturas da extremidade proximal do úmero: estudo comparativo entre dois métodos de fixação"

Copied!
6
0
0

Texto

(1)

O

riginal

a

rticle

PROXIMAL HUMERUS FRACTURES: COMPARATIVE

STUDY OF TWO DIFFERENT FIXATION METHODS

ricardo SouZa E SiLva morELLi, rodrigo EiSLEr dE SouZa traviZanuto

Citation: Morelli RSS, Travizanuto RES. Proximal humerus fractures: comparative study of two different fixation methods. Acta Ortop Bras. [online]. 2010; 18(2):79-84. Available from URL: http://www.scielo.br/aob.

All the authors declare that there is no potential conflict of interest referring to this article. Department of Orthopedics and Traumatology of Hospital Vera Cruz de Campinas. SP. Brazil.

Study conducted in the Department of Orthopedics and Traumatology of Hospital Vera Cruz.

Mailing address: Departmento de Ortopedia e Traumatologia Hospital Vera Cruz Rua Albano de Almeida Lima 212 Bairro: Guanabara Cidade: Campinas – SP. Brazil. CEP: 13170. Email: ricardomorelli@uol.com.br

Article received on 10/29/08 and approved on 05/29/09

artigo 113

IntroduCtIon

The shoulder joint allows considerable range of movements. The harmonious arrangement of the joints, muscles and ligaments of the shoulder girdle is essential for the positioning of the hand in space. Disarrangements caused by traumatism of the proximal extremity of the humerus and adjacent soft parts may lead to important func-tional limitation, generating dependence and loss of quality of life.1 If not treated adequately, its fractures can result in defective con-solidation, alteration in the mechanical axes and lever arms with consequent functional insufficiency not only of the shoulder, but of the entire limb.

These fractures correspond to between two and three percent of all upper limb fractures,2 are more common in female patients over 60 years of age and are closely related to low bone density.3 Those that occur in younger patients have distinct epidemiological and clinical characteristics with more frequency and are determined by high-energy trauma.4

Several factors determine the prognosis of these lesions, whereas the choice of adequate treatment for the patient is one of those with the greatest influence. Publications on this topic show that the treatment is controversial.5,6 In patients with low bone density their ABSTRACT

Objectives: The present study compares results of the treatment of patients with proximal humerus fractures using two different fixation methods: The T plate (Group A) for small segments that provides a relative stabilization is compared to the locking screw plate that promotes a rigid fixation. Methods: Eighteen patients were randomly divided into two groups and evaluated prospectively according to clinical aspect, functional score and radiographic parameters of displacement after fixation. Results: Using the Visual Analogue Scale – VAS, the mean pain at six months of follow-up was 2.1 for Group A and 2.2 for Group B. The mean range of forward elevation was 140o in Group A and 143o in group B. The mean UCLA functional scale scores were 30 and 31, respectively.

On the radiographic evaluation, the fractures of three patients in Group A had between 0 and 10 degrees of displacement after stabilization and six patients had displacement between 11 and 40 degrees; for Group B, seven patients had displacement between 0 and 10 degrees and three between 11 and 40 degrees. Conclu-sion: No early or late differences were found between groups in clinical and functional evaluations. In both groups, the prevalence of good results was observed. The reduction of the anatomical neck angles of the proximal humerus was closer to normal in the blocking screw group.

Keywords: Humerus fractures. Osteoporosis. Fracture fixation, Internal. Prospective studies. Comparative study.

fixation with the necessary stability continues a major challenge.7 In the choice of the material and ideal fixation technique, two funda-ments should be contemplated: adequate stability and implants of low volume. The need to respect tissue biology, the subacromial space and at the same time the obtainment of mechanical stability of the system can be conflicting objectives. A repercussion of this dilemma is the diversity of techniques and the different kinds of osteosynthesis materials advocated, a result of the dissatisfaction over the considerable incidence of complications, such as loss of the reduction, non-consolidation, osteonecrosis, reduction of the arc of movement and residual pain.1

While the discussion of which would be the best surgical implant option for these fractures persists, there is consensus that deviated fractures in healthy patients, or with comorbidities under clinical control and with preserved motor and cognitive function, should be treated with reduction, stabilization and early rehabilitation.5 This prospective study is aimed at comparing the result of two internal fixation techniques in a specific group of patients: individu-als with two- and three-part fractures of the proximal end of the humerus according to Neer,8 over 50 years of age, resulting from low kinetic energy traumatism. There is an evaluation of the early

(2)

Figure 1 – T plate.

Figure 2 – Plate and locking screws. clinical and functional results and of the objective radiographic

analysis of the maintenance or non-maintenance of the reduction obtained in the immediate postoperative stage.

MEtHodS

Between February 2006 and October 2007, 18 patients with proxi-mal humerus fractures in two and three parts according to Neer’s classification were preselected according to the inclusion criteria. The rules of the Institutional Review Board were complied with and followed.

These patients were allocated consecutively in a random manner by means of a draw in two groups: (Group A) nine patients, who had their fractures fixed with the use of T plates and small fragment screws and (Group B), another nine patients in which these were stabilized by plates specifically designed for this anatomical region, fixed by screws locked on the actual plate.

The inclusion criteria were: 1) two-part fracture (surgical neck) or three-part fracture (surgical neck and greater tubercle); 2) low energy of the traumatism; 3) sound patients or patients with comorbidities; 4) patients that were functionally independent before the trauma. The trauma mechanism in all the cases was the fall to the ground. No patient exhibited associated lesions. The cases were operated at an average time of one week after the fracture date (varying between five and nine days). The surgeries in both groups were conducted with a similar technique, only varying in terms of the type of implant used. Surgical access was performed by deltopectoral route, with mini-mum tissue aggression. Two suture sites were positioned previously in the supraspinous and subscapular tendons, close to the bone attachment. These were used to assist in the reduction and as adjuvants to the fixation of the fragment proximal to the plate. The reduction is obtained by indirect methods, without the use of bone forceps or direct manipulation of the focal point of fracture and under radioscopy. Temporary fixation was performed when necessary with crossed Steinman wires. From this moment on, the plate is set on the fracture, sometimes using it to optimize the reduction. The greater tubercle is the key fragment for obtainment of system stability, and the exact reduction of this component of the fracture is essential.7 Two different principles are henceforth applied. The patients from group A have their fractures fixed with the principle of relative stabil-ity. T plates are used with the screws positioned far from the focal point of the fracture. (Figure 1) Those from group B are stabilized with a stiffer fixation, through a configuration in the implant-bone system that allows the neutralization of the acting forces, with little dependence on bone quality, on account of the use of screws that are locked on the plate. (Figure 2)

Postoperative rehabilitation was the same for both groups. The use of a splint for seven to ten days was recommended for comfort and pain relief. Passive and active exercises for the elbow and hand were carried out according to the pain tolerance of the patient, who is encouraged to start them as early as possible. Formal physio-therapy is started on the 10th day, with an emphasis on the gain of amplitude of movement, by means of assisted passive exercises, respecting pain. Active exercises for the deltoid and rotator cuff muscles are introduced after the sixth week with the use of elastics and the passive exercises are maintained.

The patients were examined at regular intervals after one and six postoperative months. The clinical parameters were based on the subjective scaling of pain, by means of the visual analog scale (VAS), (self-evaluated scale from 0 to 10, where zero corresponds to no pain and 10 to extreme pain) and on the amplitude of eleva-tion, lateral rotation and medial rotation movements following the standardization of AAOS.9

The functional evaluation was carried out in the sixth month by the criteria of UCLA (University of California at Los Angeles).10 The results were distributed in four groups, considered excellent when between 34 and 35 points, good between 28 and 33, fair between 21 and 27 and poor between zero and 20.11

The radiological evaluation was documented in the true anteropos-terior incidence, paying attention to the consolidation parameters and quality of the reduction obtained in the immediate tive stage. These were compared with those of the sixth postopera-tive month. Transparencies of the contralateral side were obtained to facilitate and to improve the precision of measurements in the frontal plane of the epiphyseal-diaphyseal angle. (Figure 3) The radiographic results observed were distributed in four groups: in the first of them when no deviation was observed or with deviation between 0o and 10o, in the second when deviation between 11o and 20o was observed, in the third with deviation between 21o and 40o and in the fourth deviations over 40o. In the case of deviation they described the deformity observed (varus or valgus).

(3)

Figure 3 – Radiographic measurements.

table 1 – Characteristics of the groups.

T Plate Locked Plate

Gender 1M 8F 1M 8F

Average Age 66 (50 to 80) 68 (50 to 80)

2-part fracture 4 3

3-part fracture 5 6

table 2 – Mean Value of the Arc of Movement Amplitude.

Elevation Lateral rotation

Group A - 1 month 95o 19o

Group B - 1 month 90o 27o

Group A - 6 month 140o 40o

Group B - 6 month 143o 43o

Figure 4 – Mean value of the visual analog scale of pain.

Visual Scale of Pain

4.1 4.2 2.1 2.2 0 1 2 3 4 5 6 7 8 9 10 T Plate 1 month LockedPlate

1 month

T Plate 6 months LockedPlate

6 months

StAtIStICAL MEtHod

We adopted the significance level of 5% (0.05) for the application of the statistical tests. It was considered a significant difference when p < 0.05.

We applied the Mann-Whitney test to verify possible differences be-tween both the groups considered, in the various variables of interest.

rESuLtS

Nine patients (eight women and one man) were evaluated in group A (T plate), aged 66 years on average (minimum of 50 and maxi-mum of 80 years), with four two-part fractures and five three-part fractures. Nine patients (eight women and one man) were assessed in group B (locked plate), aged 68 years on average (minimum of 50 and maximum 80 years), with three two-part fractures and six three-part fractures (Table 1).

was 19o (with maximum of 40o and minimum of zero degrees) and in the sixth month it was 40o (with maximum of 70o and minimum of 20o). As for medial rotation in the first month, seven patients reached between the sacroiliac joint and L3 and two arrived at L3 and in the sixth month one of them reached L4 and the other eight surpassed T12.

In group B, the mean elevation in the first month was 90o (with maximum of 110o and minimum of 60o) and in the sixth month it was 143o (with maximum of 170o and minimum of 110o). The mean lateral rotation in the first month was 27o (with maximum of 45o and minimum of 10o) and in the sixth month it was 43o (with maximum of 60o and minimum of 20o). As for medial rotation in the first month, seven patients reached between the sacroiliac joint and L3 and two arrived at L3; in the sixth month one patient reached L4, two between L4 and L1 and five above T12. (Table 2)

The differences were not significant in the first and sixth month for elevation (p = 0.44 and 0.93), for lateral rotation (p = 0.22 and 0.68) and for medial rotation (p= 0.19 and 0.40).

At six months, in Group A, four patients managed to actively raise their arms above 150o, three between 120o and 150o, and two be-low 120o. In Group B, four patients raised their arms above 150o, three others between 120o and 150o and the other two reached less than 120o. (Figure 5)

The radiographic evaluation of the immediate postoperative period showed that in Group A, three patients maintained a difference in the epiphyseal –diaphyseal angle between 0 and 10o in relation to the opposite side, four between 11 and 20o and two between 21 and 40o. In group B in seven the difference was between 0 and 10o, one between 11 and 20o and one between 21 and 40o. (Fig-ure 6) The angles of reduction obtained when using the plates with locked screws were significantly closer to the normal anatomical parameters than those using the T plates (p = 0.02).

In group A, the mean value obtained on the visual analog pain scale was 4.1 in the first postoperative month (with a maximum of six and minimum of one) and 2.1 in the sixth month (with a maxi-mum of five and minimaxi-mum of zero). In group B the mean value was 4.2 in the first postoperative month (with maximum of seven and minimum of two) and 2.2 in the sixth month (with a maximum of four and minimum of zero). In the evaluations in the first and sixth month the differences did not show statistical significance (p=0.99 and 0.42 respectively). (Figure 4)

In relation to the arc of movement, in Group A, the mean elevation in the first month was 95o (with maximum of 130o and minimum of 45o) and in the sixth month it was 140o (with maximum of 160o and minimum of 80o). The mean lateral rotation in the first month

(4)

Figure 5 – Amplitude of Elevation Movement at six months. Elevation movement at 6 months

1 1 3 4 0 2 3 4 0 1 2 3 4 5 0 to 89 90 to 119 120 to 149 >= 150 Degrees Number of Patients T Plate Locked Plate

Figure 6 – Radiographies from the immediate PO period. Degrees of deviation.

Radiography Immediate PO period. Degrees of Deviation

3 4 2 7 1 1 0 1 2 3 4 5 6 7 8

0 to 10 degrees 11 to 20 degrees 21 to 40 degrees

Degrees Number of Patients

T Plate Locked Plate

Figure 7 – Increase of the radiographic deviation in relation to the

im-mediate PO period. 5 1 1 2 6 2 0 1 0 1 2 3 4 5 6 7 ditto Poi Degrees Number of Patients T Plate Locked Plate Increase of the Radiographic deviation 6 months PO

increase of 1 to 5 degrees increase of 6 to 10 degrees increase of 11 to 20 degrees UCLA evaluation 1 6 2 1 6 2 0 1 2 3 4 5 6 7 Excellent

(34 and 35) (28 to 33)good (21 to 27)Regular Number of Patients

T Plate Locked Plate

Figure 8 – Functional evaluation UCLA scale.

Figure 9 – T plate backward travel of the plate and proximal screws. In the evaluation performed at six months, all the patients had

their fractures consolidated and none of them exhibited defective consolidation of the greater tubercle. In group A five patients con-tinued with the same reduction as in the immediate postoperative stage, in one there was increase of deviation between 1o and 5o, in one between 6o and 10o and in another two between 11o and 20o. In Group B, six patients did not have modification in the reduction angle, while in two there was increase of the deviation between 1o and 5o and in one between 11o and 20o. (Figure 7) The differences among the groups were not significant (p = 0.45).

one patient with an excellent outcome, six good and two regular, in Group B one patient with an excellent result, six good and two regular. (Figure 8)

In neither of the groups were there complications such as: infec-tions, delayed consolidation or, taking into account the short follow-up period, signs of avascular necrosis. In the fixations performed with the T plate (Group A) we observed on two opportunities a slight retreat of proximal screws (Figure 9) and in the locked plate group (Group B) in one case this plate was poorly positioned initially, at a distance and with two screws overreaching the epiphyseal joint surface. (Figure 10)

dISCuSSIon

Proximal humerus fractures are mostly minimally deviated and sta-ble, allowing conservative treatment.6,12 However, between 15 and 20% of these fractures appear with significant deviations.4 In unsta-ble fractures, closed reduction methods, if not accompanied by fixa-tion, are ineffective and have unsatisfactory functional results.5,13 There is a prevalence of these fractures in female patients, par-ticularly after menopause, where the reduction of bone mass is frequent.14-16 The inclusion criteria of this study aimed to contem-plate precisely this specific group of individuals, where the fixation In the functional evaluation by the UCLA scale Group A had an

average of 30 points (minimum of 21 and maximum of 35) and Group B, an average 31 points (minimum of 24 and maximum of 34), without significant difference (p = 0.85). In Group A there was

(5)

Figure 10 – Locked plate, screws perforating the epiphysis.

of the implant in the bone is often precarious, hindering the obtain-ment of adequate stability that guarantees the consolidation of the fragments in a good position, as a condition for the reestablishment of good function in the affected limb.

The decision for the best treatment method starts to become con-troversial as soon as these fractures are classified. The two clas-sifications used the most often, those of Neer8 and AO17,have a low interobserver concordance18 and do not highlight relevant aspects of these lesions, like the size of the posteromedial metaphyseal component united to the epiphysis, the integrity of the soft parts in the posteromedial region of the humerus neck and the bone quality. It is known that these factors influence the evolution and the stability of these fractures and should be attentively identified in decision making when choosing the best treatment method.7

Among the various osteosynthesis options we can cite tension bands,19,20 percutaneous fixation,21,22 bone suture,23 in our milieu PFS80,24 T plates,25,26 intramedullary fixation,27,28 fixation with fixed angle blade plate,29 semitubular plate,30 locked plate for proximal humerus31,32 and other methods. This study compares two of these implants with different principles. The relative stability provided by the T plate with 3.5 mm screws in contrast to the neutralization of the deforming forces obtained by fixation with plate and locked screws. T plates with 4.5 mm screws were used a lot by the AO school in the treatment of these fractures.25,33 But the results with this kind of implant have not always proved satisfactory, particularly in dealing with patients with osteoporosis.26 There are few published mechanical assays that make a reference to their behavior. These implants are characterized by promoting a stiff assembly, which when used in dense bones allow considerable tolerance of initial deforming loads, yet do not maintain the same behavior as of when they are cyclically solicited.34,35 We emphasize, however, that the above mentioned T plate and the manner in which it is employed is very different from that used in this study. The plate thus described is that of large fragments, robust and thick, using 4.5 mm screws and acting with a neutralization plate. The one reported in this study, however, corresponds to the plate of small fragments, designed for the treatment of distal radius fractures. With its thin profile, it occupies a small area, does not

obliterate the subacromial space, is more elastic and for this reason adapts well to the anatomical and mechanical characteristics and to the most adequate principles for stabilization of a porotic bone. The other implant of this study, the plate with locked screws, be-haved adequately in biomechanical assays. In locking the screw on the plate and with these arranged in a divergent manner, one achieves a larger fixation area, which favors greater stability of the system, decreasing its chances of failure.35-38 Although there are reports in clinical practice of some difficulties in its placement and complications,39 good results were reported with its use.31,40,41 Uniform principles were followed in the treatment of the patients from both groups. In the surgical act there was the same concern with the preservation of the soft tissue envelope and the incentive for early rehabilitation dictated the same physiotherapy protocol. We sought to minimize any other technical difference that was not the implanted material. The reduction of the number of variables involved made a comparison of two different mechanical principles of fixation in these fractures possible under equal conditions. The T plate with its thin profile and arrangement of the screws fur-ther from the focal point of the fracture allows a better distribution of the cyclic solicitations over all the components involved in the fracture stabilization, thus avoiding overload in a critical area, the screw interface in the mechanically insufficient bone.7,34

In turn, the plate with locked screws used in this study also merits special emphasis as it is a delicate material, not obstructing the subacromial space. The screws anchored on the actual plate per-mit a firm assembly, which neutralizes the forces that act on the focal point of the fracture, without depending on bone quality.35-38 Compared clinically, the two groups did not show any difference in the mean postoperative pain determined and in the parameters of amplitude of elevation and rotation movements, both in the evalu-ations performed 1 month and 6 months after surgery.

The fact that a significant number of patients in both groups achieve an arc of functional movement is related to some factors. One of the most important is the possibility of accomplishing and of maintaining the fracture reduction, reestablishing the anatomi-cal parameters close to normal and thus the preservation of the biomechanical conditions of the joint. The slight aggression to the periarticular tissues and the thin profile of the implants facilitate the sliding of the plate in the subacromial space. And the degree of stability obtained, which allows early rehabilitation with exercises for gain of amplitude without the fear of losing the reduction. Complications are relatively frequent in the treatment of these frac-tures, and include humeral head osteonecrosis,5,19,21 with percent-ages reported from 0 to 45% of the cases. This outcome was not observed in any of the cases of this study. It should be considered, however, that the follow-up time is short, (it is not uncommon for epiphyseal necroses to manifest only a year after the trauma)1 and that the fractures included in the study, type two and three of Neer, are less prone to this outcome. The avoidance of excessive dissection to obtain the reduction and the non-use of voluminous implants might also have contributed to the consolidation of all the fractures without vascular affliction.

The complication observed the most in this study was defective con-solidation. It was more frequent in Group A, and its main determinant was an insufficient initial reduction. However in just two cases the deviation was greater than 20o (26o and 30o). We attributed these deviations to the concern of not using direct reductions or greater de-tachment of tissue to better expose the focal point of fracture. There

(6)

REFERENCES

1. WarnerJP, Costouros JG, Gerber C. Fractures of the proximal humerus. In: Bucholz RW, Heckman JD, Court‑Brown CM, editors. Rockwood & Green’s fractures in adults. Philadelphia: Lippincott Williams & Wilkins; 2006.p.1164‑7.

2. Lind T, Kroner K, Jensen J. The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg. 1989;108:285‑7.

3. Palvanen M, Kannus P, Niemi S, Parkkari J. Update in the epidemiology of proximal humeral fractures. Clin Orthop Relat Res. 2006;(442):87‑92.

4. Court‑Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37:691‑7.

5. Misra A, kapur R, Maffulli N. Complex proximal humeral fractures in adults ‑ a systematic review of manegement. Injury. 2001;32:363‑72.

6. Zyto K. Non‑operative treatment of comminuted fractures of the proximal humerus in elderly patients. Injury. 1998;29:349‑52.

7. Hertel R. Fractures of the proximal humerus in ostoporotic bone. Osteoporos Int. 2005;16(Suppl 2):S65‑72.

8. Neer CS 2nd. Displaced proximal humeral fractures: Part I. Classificationn and evaluations. J Bone Joint Surg Am. 1970;52:1077‑89.

9. American Academy of Orthopaedics Surgeons. Joint motion: method of measuring and recording. Chicago: American Academy of Orthopaedics Surgeons; 1965. 10. Ellman H, Hanker G, Bayer M. Repair of the rotator cuff. End‑result study of factors

influencing reconstruction. J Bone Joint Surg Am. 1986;68:1136‑44.

11. Romeo AA, Mazzocca A, Hang DW, Shott S, Bach BR Jr. Shoulder scoring scales for the evalution of rotator cuff repair. Clin Orthop Relat Res. 2004;(427):107‑14. 12. Fjalestad T, Stromsoe K, Blucher J, Tennoe B. Fractures in the proximal humerus:

functional outcome and evaluation of 70 patients treated in hospital. Arch Orthop Trauma Surg. 2005;125:310‑6.

13. Olsson C, Nordquist A, Petersson CJ: Long‑term outcome of a proximal humerus fracture predicted after 1 year: a 13 year prospective population – based follow‑up study of 47 patients. Acta Orthop. 2005;76:397‑402.

14. Buhr AJ, Cooke AM. Fracture patterns. Lancet. 1959;1:531‑6.

15. Garraway WM, Stauffer RN, Kurland LT, O’Fallon WM. Limb fractures in a defined population. I. Frequency and distribution. Mayo Clin Proc. 1979;54:701‑7 16. Horak J, Nilsson B. Epidemiology of fractures of the upper end of the humerus.

Clinic Orthop Relat Res 1975;(112):250‑3.

17. Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10(Suppl 1):1‑154. 18. Siebenrock KA, Gerber C. The reproducibility of classification of fractures of the

proximal end of the humerus. J Bone Joint Surg Am. 1993;75:1751‑5.

19. Cornell CN. Tension‑band wiring supplemented by lag‑screw fixation of proximal humerus fractures: a modified technique. Orthop Rev. 1994;Suppl:19‑23. 20. Menniti EL, Brasil Filho R, Filardi Filho CS, Baptista MV, Daher SS. Banda de tensão

intramedular com parafusos em fraturas do colo do úmero em duas e três partes: “sistema pára‑quedas”. Rev Bras Ortop. 1997;32:713‑7.

21. Jaberg H, Warner JJ, Jakob RP. Percutaneous stabilization of unstable fractures of the humerus. J Bone Joint Surg Am. 1992;74:508‑15.

22. Resch H, Huebner C, Schwaiger R. Minimally invasive reduction and osteosynthesis of articular fractures of the humeral head. Injury. 2001;32(Suppl 1):SA25‑32. 23. Hawkins RJ, Bell RH, Gurr K. The three‑part fracture of the humerus. Operative

treatment. J Bone Joint Surg Am. 1986;68:1410‑4.

24. Checchia SL, Santos PD, Miyazaki AN, Fregoneze M, Silva LA, Lobo AC et al.

Avaliação do tratamento cirúrgico da fratura em duas partes do colo cirúrgico do úmero com placa PFS 80®*. Rev Bras de Ortop. 2004;39:555‑67.

25. Wijgman Aj, Roolker W, Patt TW, Raaymakers EF, Marti RK. Open reduction and internal fixation of three and four part fractures of the proximal part of the humerus. J Bone Joint Surg Am. 2002;84:1919‑25.

26 Hessmann M, Baumgaertel F, Gehling H, Klingelhoeffer I, Gotzen L. Plate fixation of proximal humerus fracture of indirect reduction: surgical technique and results utilizing three shoulder scores. Injury. 1999;30:453‑62.

27. Zifko B, Poingenfurts J, Pezzei C, Stockley I. Flexivel intramedullary pins in the treatment of instable proximal humerus fracture. Injury. 1991;22:60‑2.

28. Ferreira Neto AA, Ferreira Filho AA, Zoppi Filho A, Benegas E, Negri JH, Machado LF et al. Osteossíntese das fraturas em duas e três partes da extremidade proxi‑ mal do úmero com hastes de Ender modificadas associadas com amarrilhos de ‘‘Ethibond”. Rev Bras Ortop. 1997;32:707‑12.

29. Hintermann B, Trouillier HH, Schafer D. Rigid internal fixation of fractures of the proximal humerus in old pacients. J Bone Joint Surg. Br. 2000 82:1107‑12. 30. Instrum K, Fennell C, Shrive N, Damson E, Sonnabend D, Holingshead R. Semitu‑

bular blade plate fixation in proximal humerus fracture: a biomechanical study in a cadaveric model. J Shoulder Elbow Surg.1998;7:462‑6.

31. Plecko M, Krauss A. Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Oper Orthop Traumatol. 2005;17:25‑50.

32. Ring D. Current concepts in plate and screw fixation of osteoporotic proximal humerus fractures. Injury. 2007;38(Suppl 3):S59‑S68.

33. Speck M, Regazzoni P. 4‑fragment fractures of the proximal humerus. Alternative strategies for surgical treatment. Unfallchirurgie. 1997;100:349‑53.

34. Lill H, Hepp P, Korner J, Kassi JP, Verheyden AP, Josten C, Duda GN. Proximal hume‑ rus fractures: How stiff should an implant be? A comparative mechanical study with new implants in humans specimens. Arch Orthop Trauma Surg. 2003;123:74‑81. 35. Hepp P, Josten C. Biology and biomechanics in osteosynthesis of proximal humerus

fractures. Eur J Trauma Emerg Surg. 2007;33:337‑44.

36. Helmy N, Hirtermann B. News trends in the treatment of proximal humerus fractures. Clin Orthop Relat Res. 2006;(442):100‑8.

37. Siffri PC, Peindl RD, Coley ER, Norton J, Connor PM, Kellam JF: Biomechani‑Siffri PC, Peindl RD, Coley ER, Norton J, Connor PM, Kellam JF: Biomechani‑ cal analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma. 2006;20:547‑54.

38. Weinstein DM, Bratton DR, Ciccone WJ 2nd, Elias JJ. Locking plates improve torsional resistance in the stabilization of three‑part proximal humeral fractures. J Shoulder Elbow Surg. 2006;15:239‑43.

39. Tolat AR, Amis A, Crofton S, Sinhá J. Failure of humeral fracture fixation plate in a young patiente using the Philos system: case report. J Shoulder Elbow Surg. 2006;15:e44‑e7. 40. Björkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal huemrus

fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 14 year. Acta Orthop Scand. 2004;75:741‑5.

41. Koukakis A, Apostolou CD, Taneja t, Korres DS, Amini A. Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res. 2006;442:115‑20.

42. Fankhauser F, Boldin C, Schippinger G, Haunschimid C, Szyszkowitiz R. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005;(430):176‑81.

was preference for less aggression to the fracture environment to the detriment of a more exact reduction. In Group B it was less frequent, only exceeding 20o (24o) in one case. The previous obtainment of epiphyseal-diaphyseal angles close to normal is a technical prereq-uisite for the adequate application of the plate with locked screws. There was also partial loss of the reduction initially obtained in the immediate postoperative stage, in four patients (increase of 6o, 10o 16o and 16o in relation to the initial reduction) in group A, in some cases accompanied by the backward travel of the plate and of the proximal screws. The lack of integrity of the medial cortical and the accommodation of the fixation system must have contributed to this. In Group B there were also minor losses of the reduction initially obtained, in three patients, but to a lesser degree (4o, 4o and 16o). In both groups, the correlation between flawed consolida-tion and worst funcconsolida-tional results was not possible, which can be explained by the small magnitude of the deviations.

In group B, in one case the placement position of the plate was inadequate, located far from the bone and with screws perforating the epiphysis. In this case the functional result was not satisfactory, with UCLA at six months of 24.

Although it was not a prior analysis parameter, it was noticed that the technique for placement of the plate with locked screws calls for greater surgical detailing, which is a difficulty already described by other authors,42 who reported 13.7% of complications due to faults in the adequate positioning of the implant.

ConCLuSIon

The clinical and functional results, adopting as parameters: the analog scale of pain, the arc of movement and the UCLA scale were similar in the two groups studied.

The radiographic parameters showed that the relation between humer-al epiphysis and diaphysis obtained with the plates and locked screws was closer to normal anatomical angles. With the T plates there was partial loss of the position achieved in the immediate postoperative period in some cases. However, the small magnitude of these devia-tions did not compromise the clinical and functional results.

The epidemiological characteristics, type of fracture, surgical and rehabilitation techniques were similar in these two groups. With the number of patients studied neither implant proved superior to the other.

Referências

Documentos relacionados

The aim of the present study was to assess the complications from treatment among patients who underwent open reduction and internal fixation of fractures of the proximal

The aim of this study was to evaluate the clinical and radiographic results and complications from fractures of the proximal third of the humerus treated with the Philos ® plate

Treatment of Neer type 4 impacted valgus fractures of the proximal humerus with open reduction, elevation, and grafting. Acta Orthop

The outcome in early cases of treatment of subtrochanteric fractures with proximal femur locking compression plate. Crist BD, Khalafi A, Hazelwood SJ,

Our study provides an epidemiological basis for rotator cuff ruptures in patients with fractures of the proximal humerus undergoing fixation with a slightly curved locked

A CT scan of the humerus revealed multiple lytic lesions in the proximal region of the humerus, involving the epiphysis, the metaphysis and the proximal diaphysis, as well

16 CAMBI, Eduardo. FOGAÇA, Mateus Vargas. 18 CÂMARA, Alexandre Freitas. O novo processo civil brasileiro. Daniel Amorim Assumpção. Novo Código de Processo Civil

Cândida Silva, School of Hospitality and Tourism, Polytechnic of Porto, Portugal Carlos Peixeira Marques, University of Trás-os-Montes e Alto Douro, Portugal Catarina Nunes,