• Nenhum resultado encontrado

J. Braz. Chem. Soc. vol.26 número5

N/A
N/A
Protected

Academic year: 2018

Share "J. Braz. Chem. Soc. vol.26 número5"

Copied!
1
0
0

Texto

(1)

Editorial

J. Braz. Chem. Soc., Vol. 26, No. 5, 831, 2015. Printed in Brazil - ©2015 Sociedade Brasileira de Química

0103 - 5053 $6.00+0.00

e

http://dx.doi.org/10.5935/0103-5053.20150093

Flow Analysis

1

Flow analysis can be acknowledged as a Brazilian triumph. In fact, the “tupiniquim”2 contributions to the

development of this technique have been outstanding, especially after the inception of flow injection analysis and the related techniques. In this context, the pioneer application of flow injection systems to large-scale analyses of waters and plants at CENA/USP3,4 and the relevant conceptual,

methodological and applicative achievements in different Brazilian institutions5 can be highlighted. These aspects

were recognized when the Journal of the Brazilian Chemical Society was launched: the flow analysts at CENA/USP were invited to collaborate with a scientific article in its first issue.6

As a Brazilian, this makes me particularly proud.

The expressive number of available flow-based analytical methods, scientific articles and monographs, academic disciplines, workshops and commercially available flow analysers demonstrates that flow analysis reached maturity.

Further development of such technique should be synergistic and not divergent. To this end, concerns for the following aspects should be borne in mind:

a) unification of concepts and terminology aiming at the convergence of ideas, improved dissemination, pedagogic aspects, etc. A specific issue refers to the representation of flow diagrams, which should follow an international format as it happens with e.g. electric circuits and hydraulic systems;

b) assortment of analytical techniques considered within the broad term “flow analysis”, as well as distinctions between the classical flow analysis and the µ-TAS.7

Moreover, deeper discussions on the interactions of the flow analysis with other techniques would be required; c) reduction of the number of manifold modalities. The present tendency towards a myriad of modalities, each one assigned by an acronym,8 is not sustainable.

The conceptual differences between some modalities are often too small to justify a specific modality name. This policy constitutes itself as a negative factor for the scientific interactions between different research groups. In this sense, multi-commutation is not a modality, but a tool to increase versatility and complexity of the flow manifold. A didactic

classification of the flow analysers could perhaps rely solely on flow pattern;

d) dissemination of novel achievements. To this end, the organization of national and international symposia, the combination of existing databases and homepages, the revision of the of flow analysis progress and the signalization of paradigm shifts are of utmost relevance; e) strengthening of the connections with the instrument

manufacturers. This would be essential for reducing the gap between the university and the enterprise, which presently impairs the prompt commercial availability of the proposed innovations.

The above-mentioned aspects could be more efficiently dealt with if web facilities were exploited, thus getting a permanent forum for discussions. In this regard, support from the Sociedade Brasileira de Química (Brazilian Chemical Society) and the organization of a virtual institute for flow analysis would be welcome.

The SBQ role in the further development of flow analysis could then be to steer the involved people and organizations towards the improved synergy. A Brazilian Society involved in a theme with a Brazilian flavour…

Elias A. G. Zagatto9

CENA/USP

References and Notes

1. Editor’s note: This is the first of a series of editorials about the state of the art of several hot areas in chemistry. We are thankful to all invited contributors and we will gladly receive suggestions and comments.

2. tupiniquim - name of an indigenous nation of Brazil, informally used as a synonym of Brazilian.

3. Hansen, E. H.; Ruzicka, J.; Trends Anal. Chem.1983, 2, 5. 4. CENA/USP - Centre for Nuclear Energy in Agriculture,

University of Sao Paulo, Piracicaba, SP, Brazil.

5. Batista, A. D.; Sasaki, M. K.; Rocha, F. R. P.; Zagatto, E. A. G.;

Analyst2014, 139, 3682.

6. Mesquita, M.; Jacintho, A. O.; Zagatto, E. A. G.; Antonio, R. F.;

J. Braz. Chem. Soc.1990, 1, 28. 7. Micro-Total Analysis Systems.

Referências

Documentos relacionados

Cleaner reactions were performed with arenediazonium tetrafluoroborates bearing electron-donating and electron-withdrawing groups in good to excellent yields with reaction

A series of novel annelated heterocyclic ring system, namely, pyrido[2,3- d ][1,2,4]triazolo[4,3- a ]pyrimidin-5- ones 6a - s were prepared via reaction of chalcone with

Preliminary experiments revealed that the carbon composite with inorganic:organic ratio of 1.3 (CC-1.3) gave better adsorption capacity for removal of reactive blue 19 (RB-19)

Electrochemical Oxidation of Landfill Leachate: Investigation of Operational Parameters and Kinetics Using Graphite-PVC Composite Electrode as Anode..

In this study a method using inductively coupled plasma source mass spectrometry (ICP-MS) for the measurement of boron isotope ratio in human dental enamel has been developed..

Hence, the center point experimental conditions were used in the derivatization procedure, where 30 µL of the rich phase from the CPE was used, in addition to 125 µL of BSTFA, 100

The proposed sensor was successfully used as an indicator electrode in potentiometric titration and also in the direct determination of this metal cation in real samples.. Keywords:

Figure 1a shows the UV-Vis absorption spectrum of the AuNP colloidal solution, where can be observed the localized surface plasmon band (LSPR) at 525 nm, which is a standard