[PDF] Top 20 Rev. IBRACON Estrut. Mater. vol.8 número4
Has 10000 "Rev. IBRACON Estrut. Mater. vol.8 número4" found on our website. Below are the top 20 most common "Rev. IBRACON Estrut. Mater. vol.8 número4".
Rev. IBRACON Estrut. Mater. vol.8 número4
... We are publishing the fourth issue of the eighth volume of the IBRACON Structures and Materials Journal. In this issue, the irst of eight articles presents interaction curves for concrete-encased com- posite ... See full document
1
Rev. IBRACON Estrut. Mater. vol.8 número4
... It was used the algorithm “Calcula_TimeHistory” to generate the corresponding functions and this way to load the nodes of the computational model in order to obtain a time series of t[r] ... See full document
16
Rev. IBRACON Estrut. Mater. vol.8 número4
... Figures 8 and 9, a comparison is presented between design charts drawn for concretes of class up to C50 and for concrete class C90, respectively (both for the rectangular section called ... See full document
10
Rev. IBRACON Estrut. Mater. vol.8 número4
... The presence of displaced semicircles suggests a non- ideal be- havior of the capacitor , leading to the introduction of the constant phase element (CPE) to the equivalent circuits. SAGUES et al. [8] introduced ... See full document
9
Rev. IBRACON Estrut. Mater. vol.8 número4
... The result graphics are the vertical displacement of the composite beam, bending moment and normal forces of each of the two beams and the connector shear force. The implementation was[r] ... See full document
11
Rev. IBRACON Estrut. Mater. vol.8 número4
... These mixtures can be used like backill material in soil retaining walls replacing the clayey soil due to its better strength and shear behavior and low unit weight.. A numerical simula[r] ... See full document
10
Rev. IBRACON Estrut. Mater. vol.8 número4
... In the beginning of the propagation time, the most probable initial failure mode is [A]. Such type of failure is, initially, obvious as the cross-section positioned at point A required the higher amount of ... See full document
12
Rev. IBRACON Estrut. Mater. vol.8 número4
... In general, the smooth models with lower compressive strength in the illed region showed slippage 2 or 3 times greater at rupture than the relative slip at the interface of the models[r] ... See full document
12
Rev. IBRACON Estrut. Mater. vol.8 número4
... Weng and Yen [19] investigated the diferences between the approaches of code ACI 318 [20] and AISC/LRFD [16] for the design of composite steel–concrete columns fully encased with concrete and evaluated how their results ... See full document
10
Rev. IBRACON Estrut. Mater. vol.8 número4
... We are publishing the fourth issue of the eighth volume of the IBRACON Structures and Materials Journal. In this issue, the irst of eight articles presents interaction curves for concrete-encased com- posite ... See full document
1
Rev. IBRACON Estrut. Mater. vol.8 número3
... Several reports of experimental tests on concrete and ceramic blocks ([3], [4], [5]) indicate that it is not valid to simply add a grout- ed area to the hollow ungrouted section to determine the prism strength. According ... See full document
12
Rev. IBRACON Estrut. Mater. vol.8 número5
... Moreover, the natural frequencies and modal shapes, which were based on the properties of the elements assigned to the structure, were obtained from the numerical model performed, via [r] ... See full document
11
Rev. IBRACON Estrut. Mater. vol.8 número5
... A Seção 4.2.4 não deixa claro se os procedimentos são váli- dos para estrutura em construção (ou nova) com problemas de conformidade ou para estruturas existentes, e omite o fato que a[r] ... See full document
3
Rev. IBRACON Estrut. Mater. vol.8 número5
... Although the example does not presents the cylinder tests results, the compressive strength values obtained from 8 cores produced much smaller results (f c, max = 19,1 MPa) than the values specifi ed in design. The ... See full document
2
Rev. IBRACON Estrut. Mater. vol.8 número5
... de um trecho da introdução e do Flowchart 1 da norma), e justii - cam o uso do critério adotado na Seção 4.2.4 tendo em vista que, nos casos de não conformidade em estruturas ainda em c[r] ... See full document
3
Rev. IBRACON Estrut. Mater. vol.8 número5
... excerpt from the introduction and Flowchart 1 of the standard), and justify the use of the criteria adopted in Section 4.2.4 with a view that in cases of non-compliance in structures u[r] ... See full document
3
Rev. IBRACON Estrut. Mater. vol.8 número3
... hydraulic conductivity values were similar for all the three mixes in both falling and constant head tests, indicating that the variation of the coarse aggregate gradation used in this[r] ... See full document
6
Rev. IBRACON Estrut. Mater. vol.8 número3
... As the ib Model Code 2010 does not present neither instructions to estimate the punching strength of slabs supported on rectan- gular columns, nor provisions to treat the cases where th[r] ... See full document
18
Rev. IBRACON Estrut. Mater. vol.8 número3
... There are already researches that present the infrared thermogra- phy as an eficient technique to evaluate defects at FRP/Concrete interface. One of them[7] uses water and air-illed debonds in dif- ferent sizes. These ... See full document
13
Rev. IBRACON Estrut. Mater. vol.8 número3
... Size effect is an important issue in concrete structures bearing in mind that it can inluence many aspects of analysis such as strength, brittleness and structural ductility, fracture [r] ... See full document
9
temas relacionados