Analysis of the structural behaviour of stiffened panels subjected to compressive loading conditions
... under compressive loads, they tend to fail by in- stability at stresses far bellow the material yielding compressive ...Because of this, stiened panels stability is a ... See full document
112
Behaviour on Non-Loadbearing Tabique Wall Subjected to Fire – Experimental and Numerical Analysis
... in the northeast ...dwellings to more urban sophisticated ones. This paper presents a study of the behaviour of tabique walls, concerning its fire ...experimental analysis ... See full document
25
Stress-strain analysis of specimens subjected to tensile loading during moisture uptake
... Behaviour of polymer materials as a rule is much more complicate than linear ...wet conditions and mechanical behaviour is especially important when it comes to the ... See full document
19
Finite element investigation on the behaviour of structural steel beams subjected to standard parametric fire
... intends to present an investigation of the behaviour of steel beams under high temperatures rise due to fire using finite elements simulations with ANSYS ...Cases of study ... See full document
6
Numerical solution of curved pipes submitted to in-plane loading conditions
... approach to curved pipes with simple first-degree ...developed to perform elastic end effects for pipe ...when subjected to bending moments, they are vulnerable components when they are ... See full document
7
A Model to predict the non-linear shear and flexural behaviour of RC elements subjected to cyclic loading
... From the observation of collapsed and severely damaged structures during recent earthquakes, it is clear the complex behaviour of RC buildings, and particularly under seismic ... See full document
5
A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading
... hysteretic behaviour of RC columns has been object of many experimental studies over the past ...However, the majority of these studies are focused on unidirectional ...different ... See full document
16
Behaviour of reinforced concrete column under biaxial cyclic loading: state of the art
... contribution of non-structural elements to the structural response is typically not considered in the de- sign of new buildings and in the assessment of ... See full document
12
Performance of infill stiffened steel panel against blast loading
... like the response of steel shear wall against earthquake. On the other hand, failure modes of in-plane action of steel panel against blast are the same as earthquake, except ... See full document
15
Parametric study of a historical masonry building subjected to seismic loading
... regarding the nature, origin, and effects of earthquakes in the built ...sources. The first one and most obvious is the progress of the science, which allowed to ... See full document
208
STRUCTURAL SAFETY IN WOODEN BEAMS UNDER THERMAL AND MECHANICAL LOADING CONDITIONS
... terms. The botanical terms, softwoods and hardwoods, indicate the basic structure and cell type of mois- ture within the ...from the coniferous species (pines, fi rs and spruces, for ... See full document
15
Modelling of friction stir welding processes and their influence on the structural behaviour of aluminium stiffened panels
... as the option for more than 5 integration points across thickness, did not improve the accuracy of ...results. The use of a mesh composed by square elements with 2 mm (in the ... See full document
199
Parametric Study of Square Concrete Filled Steel Tube Columns Subjected To Concentric Loading
... day, the concrete filled steel tube (CFST) columns are widely used in ...consists of a steel tube filled with concrete as shown in fig ...zones of high seismic ...are structural members, which ... See full document
4
Contact Analysis of Hip Resurfacing Devices under Normal and Edge Loading Conditions
... damage of hip resurfacing devices ...implantations. The wear and surface damage of these bearing surfaces occur through normal gait loading conditions in-vivo (after being implanted ... See full document
13
Evaluation of the Performance of Reduced Beam Section (RBS) Connections in Steel Moment Frames Subjected to Cyclic Loading
... In the present study, a new type of RBS connection that utilises a reduced web, in contrast to the more usual reduced flange, is shown to have a number of additional benefits, ... See full document
7
Dynamic crack propagation of granite subjected to biaxial confining pressure and blast loading
... understanding the dynamic crack propagation of rock under in-situ stress and blasting, the static-dynamic loading experimental platform was ...K of horizontal-to-vertical ... See full document
19
The use of dual boundary element method in the dynamic analysis of stiffened plates
... for the functions Ψ and χ for the 2D analysis are given in the ...appendix. The Dual Boundary Element Method (DBEM), as presented by Portela et ...capable of analysing ... See full document
17
On the evaluation of the mechanical behaviour of structural glass elements
... due to its essential properties of transparency, isolation and ...properties of strength, stiffness, chemical resistance and fire protection make it also attractive in several engineering ... See full document
5
PUNCHING IN FLAT SLABS SUBJECTED TO CYCLIC HORIZONTAL LOADING
... applied to the test specimen must be constant throughout the test, which is easily accomplished by placing weights on the top of the tested slab, as used in some tests described ... See full document
192
Effect of corrosive solutions on composites laminates subjected to low velocity impact loading
... all conditions analysed, the damaged area (delaminations) was higher for Kevlar/epoxy ...fact, the aramid fibres do not fail by brittle cracking, as do glass or carbon fibres, but they fail ... See full document
54