• Nenhum resultado encontrado

[PDF] Top 20 Dependency of air curtain performance on discharge air velocity (grille and back panel) in open refrigerated display cabinets

Has 10000 "Dependency of air curtain performance on discharge air velocity (grille and back panel) in open refrigerated display cabinets" found on our website. Below are the top 20 most common "Dependency of air curtain performance on discharge air velocity (grille and back panel) in open refrigerated display cabinets".

Dependency of air curtain performance on discharge air velocity (grille and back panel) in open refrigerated display cabinets

Dependency of air curtain performance on discharge air velocity (grille and back panel) in open refrigerated display cabinets

... no air movement parallel to the third ...influence on the efficiency, like Gaspar et al. [11] have observed in their ...external air movement is assumed to destabilize the air ...the ... See full document

10

Variation of the thermal performance of open multideck display case due to the procedure of setting the external air velocity

Variation of the thermal performance of open multideck display case due to the procedure of setting the external air velocity

... curtain performance on the discharge air velocity (grille and back panel) of open refrigerated display ...impact of intentional and non- ... See full document

10

Experimental analysis of aerothermodynamics performance of the air curtain subject to the systematic crossing of a solid body

Experimental analysis of aerothermodynamics performance of the air curtain subject to the systematic crossing of a solid body

... Vertical open refrigerated multideck display cabinets (VORDC) are widely used to display perishable products in supermarkets and convenience ...operation of food stores, ... See full document

10

Impact of external air currents on the performance of open multideck display case evaporators in laboratory conditions

Impact of external air currents on the performance of open multideck display case evaporators in laboratory conditions

... influence of the external air velocity on the performance of display case evaporators knowing that 46% of the total display refrigerators are open ... See full document

9

Detailed CFD modelling of open refrigerated display cabinets

Detailed CFD modelling of open refrigerated display cabinets

... range of air temperature, relative hu- midity and velocity variations measured during experimen- tal testing, the deviation between experimental data and numerical predictions is acceptable for this ... See full document

17

Experimental and Numerical quantitative evaluation of the thermal performance of refrigerated display cabinets with variation of air curtain thickness and porosity of the back panel

Experimental and Numerical quantitative evaluation of the thermal performance of refrigerated display cabinets with variation of air curtain thickness and porosity of the back panel

... based on experimental tests developed by Nascimento et ...influence of characteristics of the mathematical model, description of physical phenomena and of the numerical model that ... See full document

10

Performance variation of vertical open refrigerated display cases in-situ operation and testing according to ISO and ASHRAE standards

Performance variation of vertical open refrigerated display cases in-situ operation and testing according to ISO and ASHRAE standards

... predictions of temperature pathlines for EE1 (VORDC switched off) are shown in Figure ...the air flow inside the room tends to concentrate in its lower part due to the difference of ... See full document

8

Experimental evaluation and qualitative increase of thermal load in open refrigerated display cases due to breakage of the air curtain

Experimental evaluation and qualitative increase of thermal load in open refrigerated display cases due to breakage of the air curtain

... value of the Richardson number for optimal thermal sealing ability of the air curtain, which means that the value of the Reynolds number decreases by reducing the height/width ratio; ... See full document

8

Experimental evaluation of the influence of consumers' passing velocity on the thermal performance of open refrigerated display cabinets

Experimental evaluation of the influence of consumers' passing velocity on the thermal performance of open refrigerated display cabinets

... based in VORDC with a single jet in ...studies in a VORDC with double jet in DAG. This kind of equipment is used when is needed a "stiffer" aerothermodynamics sealing to ... See full document

10

Three-Dimensional CFD modelling and analysis of the thermal entrainment in open refrigerated display cabinets

Three-Dimensional CFD modelling and analysis of the thermal entrainment in open refrigerated display cabinets

... this air mass is discharged at low velocity across the back internal panel perforation inside conservation ...part of this air mass flow will supply the re-circulated air ... See full document

11

Comparing open and closed vertical refrigerated display cabinets at mild and tropical external environments

Comparing open and closed vertical refrigerated display cabinets at mild and tropical external environments

... number of daily defrosts has been reduced from 10 to 2, because the doors are a much more efficient barrier than just the air curtain to the external air infiltration, which also explains the ... See full document

9

Experimental study of the interference in air curtains due to the parallel transfer in front of refrigerated display cases

Experimental study of the interference in air curtains due to the parallel transfer in front of refrigerated display cases

... value of the Richardson number for optimal thermal sealing ability of the air curtain, which means that the value of the Reynolds number decreases by reducing the height/width ratio; ... See full document

7

CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets

CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets

... Most of retail food stores like supermarkets, grocery and convenience stores use open refrigerated display cabinets (ORDCs) for easy product access and viewing perishable products ... See full document

17

Influence of ambient air velocity orientation in thermal behaviour of open refrigerated display cabinets

Influence of ambient air velocity orientation in thermal behaviour of open refrigerated display cabinets

... thermal performance of ORDC, and particularly the efficiency of the re-circulated air ...effects of the ambient air temperature and relative humidity; indoor air flow; ... See full document

10

Numerical experimental evaluation of the aerodynamic drag of the air curtain in Vertical Open Refrigerated Display Cabinets

Numerical experimental evaluation of the aerodynamic drag of the air curtain in Vertical Open Refrigerated Display Cabinets

... will of obtaining cooling ways that make the temperature of foods products to reach a value below the environmental temperature in order to preserve them for longer periods of ...Cold ... See full document

8

Experimental quantitative evaluation of thermal performance in refrigerated displays case with variation of the thickness of the air curtain and perforation density of the back panel

Experimental quantitative evaluation of thermal performance in refrigerated displays case with variation of the thickness of the air curtain and perforation density of the back panel

... for open refrigerated display ...method of great value to industry, since usually it does not have easily the computational resources or expertise to develop CFD modelling, but it can develop ... See full document

8

CFD parametric studies for global performance improvement of open refrigerated display cabinets

CFD parametric studies for global performance improvement of open refrigerated display cabinets

... homogeneity of the air temperature in the food products conservation area and decreases the temperature difference between the returned and discharged air and thus lowering the heat ... See full document

15

Air Consumption Analysis of Air-Jet Weaving

Air Consumption Analysis of Air-Jet Weaving

... Consumption of Air-Jet Weaving Machines with Relation of Opening Duration of Sub Nozzles: Sub nozzles are the main air consumers of compressed air where 80% of ... See full document

6

Performance and Efficiency Evaluation of Air Cargo Carriers

Performance and Efficiency Evaluation of Air Cargo Carriers

... The air cargo became a very competitive and dynamic ...profitability of the cargo market and that all-cargo carriers are considerably growing due to the high ...Key Performance Areas (KPAs) and Key ... See full document

127

Geometry Effect Investigation on a Conical Chamber with Porous Media Boundary Condition Using Computational Fluid Dynamic (CFD) Technique

Geometry Effect Investigation on a Conical Chamber with Porous Media Boundary Condition Using Computational Fluid Dynamic (CFD) Technique

... geometry of a unit ...used on the CFD simulation. The burden on a simplified process was taken out from CFD ...geometry of a unit process is represented by a secondary ...boundary on a ... See full document

14

Show all 10000 documents...