• Nenhum resultado encontrado

[PDF] Top 20 Rev. IBRACON Estrut. Mater. vol.6 número2

Has 10000 "Rev. IBRACON Estrut. Mater. vol.6 número2" found on our website. Below are the top 20 most common "Rev. IBRACON Estrut. Mater. vol.6 número2".

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... The April 2013 issue of the IBRACON Structures and Materials Journal (Volume 6 Number 2) is now released. In this issue, the irst article discusses cathodic protection methods for both preventing premature ... See full document

1

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... In literature, there exist several tests that allow determining the bond stress-slip relationship. These tests can be basically subdi- vided in bar pull-out tests [3-10], beam bending tests [6, 11-13], and direct ... See full document

16

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... Brazilian standard NBR 7212 sets a time limit of 150 minutes for a concrete load to be discharged in full. In practice, situations arise where mixer trucks have to hold their load for much longer periods. The main aim of ... See full document

10

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... Regarding the strains in concrete, it is observed that near the column face, slabs LC3 and LC4 presented higher compressive strains than slab LC2.This behavior was different [r] ... See full document

18

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... Among the various nondestructive test methods available, the ultra- sonic pulse velocity method has been widely used in concrete struc- tures. It has been applied to evaluate the resistance of concrete using ... See full document

12

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... Figure 6, the values for the compliance function for 365 days from specimens loaded at 14 days was 99me/MPa and 78 me/MPa regarding specimens kept inside and outside the cham- ber, respectively ... See full document

9

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... The inite element model used for numerical simulations has shown to be a valuable tool to analyze this type of problem. Its eficiency was demonstrated when the results were compared with the ex- perimental values ... See full document

8

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... In assessing the consistency of ready mix concrete over the ive sampling points during discharge from mixer truck can observe a linear reduction of the slump from the starting [r] ... See full document

8

Rev. IBRACON Estrut. Mater.  vol.6 número2

Rev. IBRACON Estrut. Mater. vol.6 número2

... As can be seen in Figure 6, the cathodic protection current ap- plied on the steel reinforcement may cause other chemical modi- ication in the concrete. Negative ions (hydroxides, chlorides, carbonates and ... See full document

8

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... Parametric study conducted by Horowitz and Marques[6] shows that η values varies between 0.44 and 0.75, and is high- ly dependent on the ratio of beam to column section heights, thus not being convenient for ... See full document

15

Rev. IBRACON Estrut. Mater.  vol.6 número4

Rev. IBRACON Estrut. Mater. vol.6 número4

... The μ-CT is an imaging technique that allows for the gathering of three-dimensional data on the internal microstructure of materials (such as density, pore structure and porosity), which does not re- quire the special ... See full document

8

Rev. IBRACON Estrut. Mater.  vol.6 número4

Rev. IBRACON Estrut. Mater. vol.6 número4

... The results of the tests on the compressive strength of the small walls in relation to the gross area (f pp ) are shown in Table 6. Note that no signiicant change in the compressive strength of the small walls was ... See full document

15

Rev. IBRACON Estrut. Mater.  vol.6 número4

Rev. IBRACON Estrut. Mater. vol.6 número4

... In order to verify the numerical model an experimental program was carried on. It consisted on the testing of two series of hol- low core slabs. Each series had three specimens. In series 1, the hollow core slabs were ... See full document

10

Rev. IBRACON Estrut. Mater.  vol.6 número4

Rev. IBRACON Estrut. Mater. vol.6 número4

... ABNT NBR 7480 (1996) [2]. In Figure 3, the dimensions of the joists are illustrated according to the ABNT NBR 14862 (2002) [3]. Joists are indicated by a code TR, followed by ive digits: the irst two represent the height ... See full document

19

Rev. IBRACON Estrut. Mater.  vol.6 número4

Rev. IBRACON Estrut. Mater. vol.6 número4

... Four pastes with water-cementitious materials ratio of 0.47 and dif- ferent contents of replacement cement mass were designated as follows: reference paste with cement and water (RF-PC); paste with 10% cement replacement ... See full document

10

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... We are now releasing the June 2013 issue of IBRACON Structures and Materials Journal (Volume 6, Number 3). This issue contains eight articles on remarkable topics of concrete materials and struc- tures. The ... See full document

1

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... Although the mobile platforms processing capacity has in- creased during the last years, the image processing algorithm originally developed on PC software are still computationally more complex to be executed directly ... See full document

11

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... Test data was compared to results obtained from the matrix analysis program Sistema Computacional TQS v11.0 and from the inite element model program SAP2000 v14.2.2.. Slab behavior was [r] ... See full document

8

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... Prassianakis & Prassianakis [4] evaluated the ability of non-destruc- tive testing to determine the integrity of concrete specimens, and they concluded that this methodology is feasible for blocks evaluation. Hamid ... See full document

7

Rev. IBRACON Estrut. Mater.  vol.6 número3

Rev. IBRACON Estrut. Mater. vol.6 número3

... Adhesive mortars consist of cement, aggregate and other addi- tives. The most common industrially produced additives are cel- lulose ethers (HEC e MHEC) and latex polymers (PVA). Each per- form speciic functions in fresh ... See full document

7

Show all 10000 documents...